文献速递冠心病血脂与心血管预防

无创检查对稳定型心绞痛显著冠脉狭窄的诊断效能:基于验前概率的荟萃分析

The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test disease probability.
PubMed 文献 · Eur Heart J · 2018-01-01

结果显示不同检查方式的最佳PTP范围不同,负荷心电图诊断效能有限,功能成像在较宽PTP范围内对功能显著狭窄有较好判别能力。

要点

  • 负荷心电图仅在PTP≥80%时可确认解剖显著CAD,PTP≤19%时可排除。
  • CCTA在PTP≥58%时确认解剖CAD,PTP≤80%时排除解剖CAD。
  • 功能成像(PET、负荷CMR、SPECT)在PTP≥46-59%时确认功能显著CAD,PTP≤34-57%时排除。

核心结论

  • 不同诊断方式对解剖显著和功能显著冠脉狭窄的最佳PTP范围不同,负荷心电图诊断效能有限,选择检查应基于各试验最佳PTP范围和参考标准。

研究设计与样本

  • 荟萃分析,检索电子数据库至2017年8月,纳入稳定CAD患者>100例的研究,以ICA或ICA联合FFR为参考,采用分层双变量随机效应模型合并数据。

主要发现

  • 负荷心电图确认解剖显著CAD需PTP≥80%(76-83),排除需PTP≤19%(15-25)。
  • CCTA确认解剖CAD需PTP≥58%(45-70),排除需PTP≤80%(65-94)。
  • CCTA对功能显著CAD的确认PTP≥75%(67-83)、排除PTP≤57%(40-72);ICA对功能显著CAD的确认PTP≥71%(59-81)、排除PTP≤27(24-31)。
  • 功能成像(PET、负荷CMR、SPECT)确认功能显著CAD需PTP≥46-59%,排除需PTP≤34-57%。

关键数值与推荐

  • 负荷心电图:确认解剖显著CAD的PTP≥80%(76-83),排除的PTP≤19%(15-25)。
  • CCTA:确认解剖CAD的PTP≥58%(45-70),排除的PTP≤80%(65-94);确认功能显著CAD的PTP≥75%(67-83),排除的PTP≤57%(40-72)。
  • ICA:确认功能显著CAD的PTP≥71%(59-81),排除的PTP≤27(24-31)。
  • 功能成像(PET、负荷CMR、SPECT):确认功能显著CAD的PTP≥46-59%,排除的PTP≤34-57%。

临床怎么用

  • 根据患者PTP选择无创检查以排除或确认显著CAD,负荷心电图诊断价值有限,功能成像在较宽PTP范围内对功能显著狭窄有较好判别能力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD) in which stress electrocardiogram (ECG), stress echocardiography, coronary computed tomography angiography (CCTA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and cardiac magnetic resonance (CMR) can reclassify patients into a post-test probability that defines (>85%) or excludes (<15%) anatomically (defined by visual evaluation of invasive coronary angiography [ICA]) and functionally (defined by a fractional flow reserve [FFR] ≤0.8) significant CAD. METHODS AND RESULTS: A broad search in electronic databases until August 2017 was performed. Studies on the aforementioned techniques in >100 patients with stable CAD that utilized either ICA or ICA with FFR measurement as reference, were included. Study-level data was pooled using a hierarchical bivariate random-effects model and likelihood ratios were obtained for each technique. The PTP ranges for each technique to rule-in or rule-out significant CAD were defined. A total of 28 664 patients from 132 studies that used ICA as reference and 4131 from 23 studies using FFR, were analysed. Stress ECG can rule-in and rule-out anatomically significant CAD only when PTP is ≥80% (76-83) and ≤19% (15-25), respectively. Coronary computed tomography angiography is able to rule-in anatomic CAD at a PTP ≥58% (45-70) and rule-out at a PTP ≤80% (65-94). The corresponding PTP values for functionally significant CAD were ≥75% (67-83) and ≤57% (40-72) for CCTA, and ≥71% (59-81) and ≤27 (24-31) for ICA, demonstrating poorer performance of anatomic imaging against FFR. In contrast, functional imaging techniques (PET, stress CMR, and SPECT) are able to rule-in functionally significant CAD when PTP is ≥46-59% and rule-out when PTP is ≤34-57%. CONCLUSION: The various diagnostic modalities have different optimal performance ranges for the detection of anatomically and functionally significant CAD. Stress ECG appears to have very limited diagnostic power. The selection of a diagnostic technique for any given patient to rule-in or rule-out CAD should be based on the optimal PTP range for each test and on the assumed reference standard.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Knuuti J, Ballo H, Juarez-Orozco LE, et al. The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test disease probability. Eur Heart J. 2018. PMID: 29850808. doi:10.1093/eurheartj/ehy267

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。