文献速递冠心病

联合高敏肌钙蛋白I与T早期诊断急性心肌梗死

Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction.
PubMed 文献 · Circulation · 2018-01-01

本研究评估联合高敏肌钙蛋白I(hs-cTnI)与T(hs-cTnT)浓度对疑似急性心肌梗死患者的早期诊断效能。联合检测未一致提高总体诊断准确性,但可增加符合极早期安全排除标准的患者比例。优化阈值(和值9 ng/L、乘积18 ng2/L2)及联合算法(hs-cTnI<4 ng/L且hs-cTnT<9 ng/L)在推导与验证队列中均显示高阴性预测值。

要点

  • 联合hs-cTnI与hs-cTnT未一致提高总体诊断准确性。
  • 优化阈值可提高单次采血后的排除比例至34%-41%。
  • 联合算法排除的阴性预测值高,但阳性预测值有限。

核心结论

  • 联合hs-cTnI与hs-cTnT的新策略可能显著增加极早期安全排除的患者数量,但对急性心肌梗死的纳入诊断帮助不大。

研究设计与样本

  • 在大规模多中心诊断研究中评估就诊时hs-cTnI(Architect, Abbott)与hs-cTnT(Elecsys, Roche)浓度联合(和、乘积、比值及联合算法)的诊断效能,并在第二项大型多中心诊断研究中外部验证最优排除与纳入阈值。

主要发现

  • 联合hs-cTnI与hs-cTnT浓度未一致提高总体诊断准确性。
  • 应用欧洲心脏病学会2015指南推荐算法与切点时,基线采血后符合排除标准的比例有限(6%至24%)且依赖检测方法。
  • 使用和值(9 ng/L)与乘积(18 ng2/L2)优化切点后,单次采血排除比例在原始队列升至34%至41%(和值阴性预测值100%[95%CI 99.5%-100%];乘积阴性预测值100%[95%CI 99.5%-100%]),验证队列和值阴性预测值99.6%[95%CI 99.0%-99.9%]、乘积99.4%[95%CI 98.8%-99.8%]。
  • 联合算法(hs-cTnI<4 ng/L且hs-cTnT<9 ng/L)排除比例40%至43%,阴性预测值原始队列99.9%[95%CI 99.2%-100%]、验证队列99.5%[95%CI 98.9%-99.8%];纳入阳性预测值原始队列74.4%[95%CI 69.6%-78.8%]、验证队列84.0%[95%CI 79.7%-87.6%]。

关键数值与推荐

  • 优化和值切点9 ng/L、乘积切点18 ng2/L2用于单次采血排除。
  • 联合算法排除标准:hs-cTnI<4 ng/L且hs-cTnT<9 ng/L。

临床怎么用

  • 联合hs-cTnI与hs-cTnT或可增加极早期安全排除急性心肌梗死的患者比例,但不宜用于纳入诊断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction. METHODS: The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms. RESULTS: Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34% to 41% in the original (sum: negative predictive value [NPV] 100% [95% confidence interval (CI), 99.5% to 100%]; product: NPV 100% [95% CI, 99.5% to 100%]) and in the validation cohort (sum: NPV 99.6% [95% CI, 99.0-99.9%]; product: NPV 99.4% [95% CI, 98.8-99.8%]). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule-out (40% to 43% ruled out; NPV original cohort 99.9% [95% CI, 99.2-100%]; NPV validation cohort 99.5% [95% CI, 98.9-99.8%]) and rule-in (positive predictive value [PPV] original cohort 74.4% [95% Cl, 69.6-78.8%]; PPV validation cohort 84.0% [95% Cl, 79.7-87.6%]). CONCLUSIONS: New strategies combining hs-cTnI and hs-cTnT concentrations may significantly increase the number of patients eligible for very early and safe rule-out, but do not seem helpful for the rule-in of acute myocardial infarction. CLINICAL TRIAL REGISTRATION: URL (APACE): https://www.clinicaltrial.gov . Unique identifier: NCT00470587. URL (ADAPT): www.anzctr.org.au . Unique identifier: ACTRN12611001069943.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. van der Linden N, Wildi K, Twerenbold R, et al. Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. Circulation. 2018. PMID: 29691270. doi:10.1161/CIRCULATIONAHA.117.032003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。