文献速递心律失常

智能手表算法自动检测心房颤动

Smartwatch Algorithm for Automated Detection of Atrial Fibrillation.
PubMed 文献 · J Am Coll Cardiol · 2018-03-10

本研究纳入100例心房颤动患者,在电复律前后同步采集12导联心电图与Kardia Band记录,评估该智能手表算法区分窦性心律与心房颤动的准确性。结果显示算法判读心房颤动的敏感度为93%、特异度为84%,K系数为0.77;医师复核记录后敏感度达99%、特异度83%,K系数0.83。结论认为该算法配合医师复核可准确区分心房颤动与窦性心律,有助于择期电复律前的筛查。

要点

  • Kardia Band算法判读心房颤动的敏感度93%、特异度84%。
  • 医师复核Kardia Band记录后敏感度99%、特异度83%。
  • 该技术可辅助择期电复律前筛查,避免不必要操作。

核心结论

  • Kardia Band算法配合医师复核可准确区分心房颤动与窦性心律,有助于择期电复律前的筛查并避免不必要操作。

研究设计与样本

  • 连续纳入因心房颤动拟行电复律的患者,在电复律前后同步采集12导联心电图与Kardia Band记录,共获得169对同步记录。

主要发现

  • 与心电图相比,Kardia Band算法判读心房颤动的敏感度为93%、特异度为84%,K系数为0.77。
  • 医师判读Kardia Band记录的敏感度为99%、特异度为83%,K系数为0.83。
  • 57份算法无法判读的记录中,电生理医师诊断心房颤动的敏感度为100%、特异度为80%,K系数为0.74。
  • 在113例算法与医师判读均可解读的同一记录中,一致性极好,K系数为0.88。

临床怎么用

  • 可将该智能手表算法用于择期电复律前的心房颤动筛查,并由医师复核记录以提高判读准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Kardia Band (KB) is a novel technology that enables patients to record a rhythm strip using an Apple Watch (Apple, Cupertino, California). The band is paired with an app providing automated detection of atrial fibrillation (AF). OBJECTIVES: The purpose of this study was to examine whether the KB could accurately differentiate sinus rhythm (SR) from AF compared with physician-interpreted 12-lead electrocardiograms (ECGs) and KB recordings. METHODS: Consecutive patients with AF presenting for cardioversion (CV) were enrolled. Patients underwent pre-CV ECG along with a KB recording. If CV was performed, a post-CV ECG was obtained along with a KB recording. The KB interpretations were compared to physician-reviewed ECGs. The KB recordings were reviewed by blinded electrophysiologists and compared to ECG interpretations. Sensitivity, specificity, and K coefficient were measured. RESULTS: A total of 100 patients were enrolled (age 68 ± 11 years). Eight patients did not undergo CV as they were found to be in SR. There were 169 simultaneous ECG and KB recordings. Fifty-seven were noninterpretable by the KB. Compared with ECG, the KB interpreted AF with 93% sensitivity, 84% specificity, and a K coefficient of 0.77. Physician interpretation of KB recordings demonstrated 99% sensitivity, 83% specificity, and a K coefficient of 0.83. Of the 57 noninterpretable KB recordings, interpreting electrophysiologists diagnosed AF with 100% sensitivity, 80% specificity, and a K coefficient of 0.74. Among 113 cases where KB and physician readings of the same recording were interpretable, agreement was excellent (K coefficient = 0.88). CONCLUSIONS: The KB algorithm for AF detection supported by physician review can accurately differentiate AF from SR. This technology can help screen patients prior to elective CV and avoid unnecessary procedures.

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Bumgarner JM, Lambert CT, Hussein AA, et al. Smartwatch Algorithm for Automated Detection of Atrial Fibrillation. J Am Coll Cardiol. 2018. PMID: 29535065. doi:10.1016/j.jacc.2018.03.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。