文献速递冠心病瓣膜病与结构性心脏病

无钆心脏MR负荷T1 mapping鉴别心外膜与微血管冠状动脉疾病

Gadolinium-Free Cardiac MR Stress T1-Mapping to Distinguish Epicardial From Microvascular Coronary Disease.
PubMed 文献 · J Am Coll Cardiol · 2018-01-01

本研究前瞻性验证负荷T1 mapping对比有创冠状动脉测量,检测阻塞性心外膜冠状动脉疾病(FFR<0.8)和冠状动脉微血管功能障碍(FFR≥0.8且IMR≥25 U),并与首过灌注成像比较。负荷T1 mapping在检测阻塞性CAD方面显著优于钆基首过灌注成像,ΔT1=1.5%准确检测阻塞性CAD(敏感性93%,特异性95%),ΔT1=4.0%准确检测微血管功能障碍(AUC 0.95±0.03,敏感性94%,特异性94%)。

要点

  • 负荷T1 mapping无对比剂无辐射,可准确检测并鉴别阻塞性心外膜CAD与微血管功能障碍。
  • ΔT1=1.5%检测阻塞性CAD的敏感性93%、特异性95%。
  • ΔT1=4.0%检测微血管功能障碍的AUC 0.95±0.03、敏感性94%、特异性94%。

核心结论

  • 负荷T1 mapping无对比剂无辐射,可准确检测并鉴别阻塞性心外膜CAD与微血管功能障碍。

研究设计与样本

  • FFR和IMR在CMR后≤7天内评估。
  • 负荷和静息图像分析对其他信息设盲。

主要发现

  • 正常心肌T1反应性(ΔT1)为6.2±0.4%(1.5T)和6.2±1.3%(3T)。
  • 阻塞性CAD下游缺血存活心肌T1反应性近乎消失(ΔT1=0.7±0.7%)。
  • 非阻塞性冠状动脉伴微血管功能障碍下游心肌T1反应性减弱较轻(ΔT1=3.0±0.9%)。
  • 负荷T1 mapping检测阻塞性CAD显著优于钆基首过灌注成像(AUC 0.97±0.02 vs. 0.91±0.03,p<0.001)。

关键数值与推荐

  • ΔT1=1.5%准确检测阻塞性CAD(敏感性93%,特异性95%,p<0.001)。
  • ΔT1=4.0%准确检测微血管功能障碍(AUC 0.95±0.03,敏感性94%,特异性94%,p<0.001)。

临床怎么用

  • 负荷T1 mapping可作为无对比剂、无辐射的缺血生物标志物,用于鉴别阻塞性心外膜CAD与微血管功能障碍。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Novel cardiac magnetic resonance (CMR) stress T1 mapping can detect ischemia and myocardial blood volume changes without contrast agents and may be a more comprehensive ischemia biomarker than myocardial blood flow. OBJECTIVES: This study describes the performance of the first prospective validation of stress T1 mapping against invasive coronary measurements for detecting obstructive epicardial coronary artery disease (CAD), defined by fractional flow reserve (FFR <0.8), and coronary microvascular dysfunction, defined by FFR ≥0.8 and the index of microcirculatory resistance (IMR ≥25 U), compared with first-pass perfusion imaging. METHODS: Ninety subjects (60 patients with angina; 30 healthy control subjects) underwent CMR (1.5- and 3-T) to assess left ventricular function (cine), ischemia (adenosine stress/rest T1 mapping and perfusion), and infarction (late gadolinium enhancement). FFR and IMR were assessed ≤7 days post-CMR. Stress and rest images were analyzed blinded to other information. RESULTS: Normal myocardial T1 reactivity (ΔT1) was 6.2 ± 0.4% (1.5-T) and 6.2 ± 1.3% (3-T). Ischemic viable myocardium downstream of obstructive CAD showed near-abolished T1 reactivity (ΔT1 = 0.7 ± 0.7%). Myocardium downstream of nonobstructive coronary arteries with microvascular dysfunction showed less-blunted T1 reactivity (ΔT1 = 3.0 ± 0.9%). Stress T1 mapping significantly outperformed gadolinium-based first-pass perfusion, including absolute quantification of myocardial blood flow, for detecting obstructive CAD (area under the receiver-operating characteristic curve: 0.97 ± 0.02 vs. 0.91 ± 0.03, respectively; p < 0.001). A ΔT1 of 1.5% accurately detected obstructive CAD (sensitivity: 93%; specificity: 95%; p < 0.001), whereas a less-blunted ΔT1 of 4.0% accurately detected microvascular dysfunction (area under the receiver-operating characteristic curve: 0.95 ± 0.03; sensitivity: 94%; specificity: 94%: p < 0.001). CONCLUSIONS: CMR stress T1 mapping accurately detected and differentiated between obstructive epicardial CAD and microvascular dysfunction, without contrast agents or radiation.

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Liu A, Wijesurendra RS, Liu JM, et al. Gadolinium-Free Cardiac MR Stress T1-Mapping to Distinguish Epicardial From Microvascular Coronary Disease. J Am Coll Cardiol. 2018. PMID: 29495995. doi:10.1016/j.jacc.2017.11.071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。