文献速递冠心病

心脏磁共振诊断微血管性心绞痛

Diagnosis of Microvascular Angina Using Cardiac Magnetic Resonance.
PubMed 文献 · J Am Coll Cardiol · 2018-01-01

结果显示,IMR≥25 U的心肌MPRI显著受损,与阻塞性CAD下游缺血心肌相似;MPRI 1.4诊断CMD相关灌注受损的AUC为0.90,特异性95%,敏感性89%。

要点

  • CMR可无创评估NOCAD患者微血管性心绞痛。
  • MPRI 1.4诊断CMD相关灌注受损敏感性89%、特异性95%。
  • IMR≥25 U心肌MPRI受损程度与阻塞性CAD缺血心肌相似。

核心结论

  • 在NOCAD心绞痛患者中,CMR可客观、无创地评估微血管性心绞痛。

研究设计与样本

  • 后续7天内行冠状动脉造影,28例为阻塞性CAD(FFR ≤0.8),22例为NOCAD(FFR >0.8)并接受三支血管IMR测量。

主要发现

  • NOCAD患者中,IMR <25 U的心肌MPRI正常(1.9 ± 0.4 vs. 对照2.0 ± 0.3;p = 0.49)。
  • IMR ≥25 U的心肌MPRI显著受损,与阻塞性CAD下游缺血心肌相似(1.2 ± 0.3 vs. 1.2 ± 0.4;p = 0.61)。
  • MPRI 1.4准确检测CMD相关灌注受损(IMR ≥25 U;FFR >0.8),AUC 0.90,特异性95%,敏感性89%,p < 0.001。
  • NOCAD患者MPRI受损由负荷MBF增加受损驱动,静息MBF正常。
  • FFR >0.8且IMR正常(<25 U)的心肌负荷MBF仍减低,提示轻度CMD;负荷MBF阈值2.3 ml/min/g可区分对照,阳性预测值100%。

关键数值与推荐

  • MPRI 1.4诊断CMD相关灌注受损:AUC 0.90,特异性95%,敏感性89%,p < 0.001。
  • IMR ≥25 U定义CMD相关灌注受损。
  • 负荷MBF阈值2.3 ml/min/g区分轻度CMD与对照,阳性预测值100%。

临床怎么用

  • 对心绞痛且NOCAD患者,可采用腺苷负荷CMR测量MPRI和MBF无创评估微血管性心绞痛。
  • MPRI 1.4可作为诊断CMD相关灌注受损的参考阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In patients with angina and nonobstructive coronary artery disease (NOCAD), confirming symptoms due to coronary microvascular dysfunction (CMD) remains challenging. Cardiac magnetic resonance (CMR) assesses myocardial perfusion with high spatial resolution and is widely used for diagnosing obstructive coronary artery disease (CAD). OBJECTIVES: The goal of this study was to validate CMR for diagnosing microvascular angina in patients with NOCAD, compared with patients with obstructive CAD and correlated to the index of microcirculatory resistance (IMR) during invasive coronary angiography. METHODS: Fifty patients with angina (65 ± 9 years of age) and 20 age-matched healthy control subjects underwent adenosine stress CMR (1.5- and 3-T) to assess left ventricular function, inducible ischemia (myocardial perfusion reserve index [MPRI]; myocardial blood flow [MBF]), and infarction (late gadolinium enhancement). During subsequent angiography within 7 days, 28 patients had obstructive CAD (fractional flow reserve [FFR] ≤0.8) and 22 patients had NOCAD (FFR >0.8) who underwent 3-vessel IMR measurements. RESULTS: In patients with NOCAD, myocardium with IMR <25 U had normal MPRI (1.9 ± 0.4 vs. controls 2.0 ± 0.3; p = 0.49); myocardium with IMR ≥25 U had significantly impaired MPRI, similar to ischemic myocardium downstream of obstructive CAD (1.2 ± 0.3 vs. 1.2 ± 0.4; p = 0.61). An MPRI of 1.4 accurately detected impaired perfusion related to CMD (IMR ≥25 U; FFR >0.8) (area under the curve: 0.90; specificity: 95%; sensitivity: 89%; p < 0.001). Impaired MPRI in patients with NOCAD was driven by impaired augmentation of MBF during stress, with normal resting MBF. Myocardium with FFR >0.8 and normal IMR (<25 U) still had blunted stress MBF, suggesting mild CMD, which was distinguishable from control subjects by using a stress MBF threshold of 2.3 ml/min/g with 100% positive predictive value. CONCLUSIONS: In angina patients with NOCAD, CMR can objectively and noninvasively assess microvascular angina. A CMR-based combined diagnostic pathway for both epicardial and microvascular CAD deserves further clinical validation.

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Liu A, Wijesurendra RS, Liu JM, et al. Diagnosis of Microvascular Angina Using Cardiac Magnetic Resonance. J Am Coll Cardiol. 2018. PMID: 29495996. doi:10.1016/j.jacc.2017.12.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。