文献速递心律失常瓣膜病与结构性心脏病

外科手术对法洛四联症解剖峡部存在与尺寸的影响

Impact of surgery on presence and dimensions of anatomical isthmuses in tetralogy of Fallot.
PubMed 文献 · Heart · 2018-01-05

矫正标本中峡部1和3几乎均存在(各99%),峡部2仅42%、峡部4仅6%。经心房-经肺动脉矫正可避免峡部2(0% vs 100%,P<0.001),<1岁矫正者跨环补片更小,矫正方式与时机不影响峡部3。

要点

  • 经心房-经肺动脉矫正可避免峡部2形成(0% vs 经心室100%)。
  • 矫正后峡部1、3几乎均存在(各99%),峡部4罕见(6%)。
  • <1岁矫正所需跨环RVOT补片更小(28±15 vs 45±14 mm)。

核心结论

  • TOF常规经心房-经肺动脉矫正可避免峡部2;矫正方式与时机不改变峡部3的存在率与尺寸。

主要发现

  • 矫正标本83例有峡部1(99%,宽25±10 mm、厚5±2 mm),35例有峡部2(42%,宽10±9 mm、厚3±2 mm)。
  • 矫正标本83例有峡部3(99%,宽10±6 mm、厚5±2 mm),5例有峡部4(6%,宽4±2 mm、厚2±1 mm)。
  • 经心房-经肺动脉矫正(n=49)与经心室矫正(n=35)相比峡部2为0% vs 100%(P<0.001)。
  • <1岁矫正(n=7)与≥1岁(n=42)相比跨环RVOT补片更小(28±15 vs 45±14 mm,P<0.001)。
  • 峡部3宽度与厚度强相关(r=0.65,P<0.001),矫正方式与时机不影响其存在与尺寸。

临床怎么用

  • TOF矫正时选择经心房-经肺动脉途径可能减少峡部2相关室速基质,术后随访需结合矫正方式评估峡部情况。

局限性

  • 为尸检标本研究,样本为死亡病例,结果外推至存活人群需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: In tetralogy of Fallot (TOF), the dominant ventricular tachycardia substrates are slow-conducting anatomical isthmuses. Surgical correction has evolved, which might have influenced isthmus presence and dimensions. METHODS: One hundred and forty-two postmortem TOF specimens (84/58 corrected/uncorrected) were studied for isthmus presence. Isthmus 1 is located between the tricuspid annulus and right ventricular (RV) outflow tract (RVOT) patch/RV incision, isthmus 2 between RVOT patch/RV incision and pulmonary valve, isthmus 3 between pulmonary valve and ventricular septal defect (patch), isthmus 4 between ventricular septal defect (patch) and tricuspid annulus. Isthmus width and thickness were measured. RESULTS: Of 84 corrected postmortem TOF specimens (death: 6.6 years (4.0-11.5)), 83 demonstrated isthmus 1 (99%, width=25±10 mm, thickness=5±2 mm), 35 isthmus 2 (42%, width=10±9 mm, thickness=3±2 mm), 83 isthmus 3 (99%, width=10±6 mm, thickness=5±2 mm), and 5 isthmus 4 (6%, width=4±2 mm, thickness=2±1 mm). Transatrial-transpulmonary correction (n=49) as compared with transventricular correction (n=35) prevented isthmus 2 (0% vs 100%, P<0.001). Transatrial-transpulmonary correction at age <1 year (n=7) as compared with ≥1 year (n=42) required a smaller transannular RVOT patch (28±15 vs 45±14 mm, P<0.001). Mode and timing of correction did not influence presence and dimensions of isthmus 3. In corrected and uncorrected TOF specimens (death 1.8 years (0.5-6.6)), the range of isthmus 3 dimensions was broad (width: min=2 mm, max=32 mm; thickness: min=1, max 13 mm) across all ages. Isthmus 3 width and thickness were strongly correlated (r=0.65, P<0.001). CONCLUSIONS: In TOF, the current routine use of transatrial-transpulmonary correction prevents isthmus 2. Correction <1 year reduces transannular patch size, which may influence isthmus 1 width later in life. Mode and timing of correction did not change prevalence and dimensions of isthmus 3, in which dimensions varied widely in uncorrected and corrected TOF.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Kapel GFL, Laranjo S, Blom NA, et al. Impact of surgery on presence and dimensions of anatomical isthmuses in tetralogy of Fallot. Heart. 2018. PMID: 29305559. doi:10.1136/heartjnl-2017-312452

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。