文献速递冠心病

静息远段/主动脉冠状动脉压力比与瞬时无波形比值的吻合度研究

Agreement of the Resting Distal to Aortic Coronary Pressure With the Instantaneous Wave-Free Ratio.
PubMed 文献 · J Am Coll Cardiol · 2017-01-01

该前瞻性多中心研究纳入763例患者,在静息条件下测量瞬时无波形比值(iFR)与静息远段/主动脉冠状动脉压力比(Pd/Pa),以iFR≤0.89为参考标准评估Pd/Pa的吻合度。结果显示Pd/Pa可分析率显著高于iFR(96.1% vs. 82.2%),两者高度相关(R²=0.93),Pd/Pa最佳截断值≤0.91时与iFR吻合度极佳(AUC 0.98),诊断准确率93.0%。

要点

  • Pd/Pa可分析率显著高于iFR(96.1% vs. 82.2%,P<0.001)。
  • Pd/Pa与iFR高度相关(R²=0.93,P<0.001)。
  • Pd/Pa≤0.91与iFR≤0.89吻合度极佳,AUC 0.98。

核心结论

  • Pd/Pa可分析的患者数显著多于iFR,且与iFR吻合度极佳,提示其可类似地应用于临床。

研究设计与样本

  • 前瞻性多中心研究,从12家机构纳入763例患者,在静息条件下测量iFR和Pd/Pa,以iFR≤0.89为参考标准评估Pd/Pa的吻合度及最佳截断值。

主要发现

  • 独立核心实验室分析显示,iFR和Pd/Pa可分析患者分别为627例和733例(82.2% vs. 96.1%,P<0.001)。
  • iFR和Pd/Pa中位数分别为0.90(四分位距0.85-0.94)和0.92(四分位距0.88-0.95),两者高度相关(R²=0.93,P<0.001;iFR=1.31*Pd/Pa-0.31)。
  • 受试者工作特征曲线分析显示Pd/Pa吻合度极佳(AUC 0.98,95%CI 0.97-0.99,P<0.001),最佳截断值为Pd/Pa≤0.91。
  • 诊断准确率、敏感度、特异度、阳性预测值和阴性预测值分别为93.0%、91.4%、94.4%、93.3%和92.7%。
  • 在急性冠脉综合征和稳定型心绞痛患者中结果相似。

关键数值与推荐

  • 以iFR≤0.89为参考标准,Pd/Pa最佳截断值为≤0.91,诊断准确率93.0%,敏感度91.4%,特异度94.4%。

临床怎么用

  • Pd/Pa作为无需腺苷的静息指标,可分析率高于iFR,且与iFR吻合度极佳,可考虑在导管室中类似地用于指导血运重建决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recently, 2 randomized controlled trials showed that the instantaneous wave-free ratio (iFR), a resting coronary physiological index, is noninferior to fractional flow reserve for guiding revascularization. The resting distal to aortic coronary pressure (Pd/Pa) measured at rest is another adenosine-free index widely available in the cardiac catheterization laboratory; however, little is known about the agreement of Pd/Pa using iFR as a reference standard. OBJECTIVES: The goal of this study was to investigate the agreement of Pd/Pa with iFR. METHODS: A total of 763 patients were prospectively enrolled from 12 institutions. iFR and Pd/Pa were measured under resting conditions. Using iFR ≤0.89 as a reference standard, the agreement of Pd/Pa and its best cutoff value were assessed. RESULTS: According to the independent core laboratory analysis, iFR and Pd/Pa were analyzable in 627 and 733 patients (82.2% vs. 96.1%; p < 0.001), respectively. The median iFR and Pd/Pa were 0.90 (interquartile range: 0.85 to 0.94) and 0.92 (interquartile range: 0.88 to 0.95), and the 2 indices were highly correlated (R2 = 0.93; p < 0.001; iFR = 1.31 * Pd/Pa -0.31). According to the receiver-operating characteristic curve analysis, Pd/Pa showed excellent agreement (area under the curve: 0.98; 95% confidence interval: 0.97 to 0.99; p < 0.001) with a best cutoff value of Pd/Pa ≤0.91. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 93.0%, 91.4%, 94.4%, 93.3%, and 92.7%, respectively. These results were similar in patients with acute coronary syndrome and stable angina. CONCLUSIONS: Pd/Pa was analyzable in a significantly higher number of patients than iFR. Pd/Pa showed excellent agreement with iFR, suggesting that it could be applied clinically in a similar fashion. (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology? [CONTRAST]; NCT02184117).

来源:J Am Coll Cardiol,查看原文。版权归原作者所有。

引用

  1. Kobayashi Y, Johnson NP, Zimmermann FM, et al. Agreement of the Resting Distal to Aortic Coronary Pressure With the Instantaneous Wave-Free Ratio. J Am Coll Cardiol. 2017. PMID: 29050557. doi:10.1016/j.jacc.2017.08.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。