几何因素混淆心室收缩功能评估:射血分数与应变的比较
研究通过椭圆左室模型推导射血分数(EF)与整体纵向应变(GLS)、整体环向应变(GCS)、壁厚度及短轴直径的解析方程,并在100例EF 16%-72%受试者中验证。模型预测EF与实测EF高度一致(r=0.95),GCS对EF贡献是GLS的两倍以上,几何因素可解释EF保留时应变减低。
要点
- GCS对EF的贡献是GLS的两倍以上。
- GLS显著降低可由GCS或壁厚度轻度增加或直径减小代偿。
- 肥厚型心肌病患者EF与对照相似但应变减低。
核心结论
- EF保留时应变减低可由几何因素解释,应变比EF更好地反映收缩功能。
研究设计与样本
- 从椭圆左室模型推导EF与GLS、GCS、壁厚度及短轴直径的解析方程,并在100例EF 16%-72%受试者中用超声心动图验证。
主要发现
- 模型预测EF与实测EF高度一致(r=0.95)。
- GCS对EF的贡献是GLS的两倍以上。
- GLS显著降低可由GCS或壁厚度轻度增加或直径减小代偿。
- 20例对照与20例肥厚型心肌病患者EF相似,后者壁厚度增加且GCS和GLS均减低(均p<0.01)。
临床怎么用
- EF保留时评估收缩功能应结合应变,注意几何因素对EF的混淆。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Preserved left ventricular (LV) ejection fraction (EF) and reduced myocardial strain are reported in patients with hypertrophic cardiomyopathy, ischemic heart disease, diabetes mellitus, and more. OBJECTIVES: The authors performed a combined mathematical and echocardiographic study to understand the inconsistencies between EF and strains. METHODS: An analytical equation showing the relationship between EF and the 4 parameters, global longitudinal strain (GLS), global circumferential strain (GCS), wall thickness, and short-axis diameter, was derived from an elliptical LV model. The equation was validated by measuring the 4 parameters by echocardiography in 100 subjects with EF ranging from 16% to 72% and comparing model-predicted EF with measured EF. The effect of the different parameters on EF was explored in the model and compared with findings in the patients. RESULTS: Calculated EF had very good agreement with measured EF (r = 0.95). The model showed that GCS contributes more than twice as much to EF than GLS. A significant reduction of GLS could be compensated by a small increase of GCS or wall thickness or reduced diameter. The model further demonstrated how EF can be maintained in ventricles with increased wall thickness or reduced diameter, despite reductions in both longitudinal and circumferential shortening. This was consistent with similar EF in 20 control subjects and 20 hypertrophic cardiomyopathy patients with increased wall thickness and reductions in both circumferential and longitudinal shortening (all p < 0.01). CONCLUSIONS: Reduced deformation despite preserved EF can be explained through geometric factors. Due to geometric confounders, strain better reflects systolic function in patients with preserved EF.
引用
- Stokke TM, Hasselberg NE, Smedsrud MK, et al. Geometry as a Confounder When Assessing Ventricular Systolic Function: Comparison Between Ejection Fraction and Strain. J Am Coll Cardiol. 2017. PMID: 28818204. doi:10.1016/j.jacc.2017.06.046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。