文献速递心力衰竭与心肌病心律失常

植入式电子设备远程管理心力衰竭的随机对照试验

Remote management of heart failure using implantable electronic devices.
PubMed 文献 · Eur Heart J · 2017-01-01

REM-HF 试验将 1650 例心衰合并心脏植入式电子设备的患者随机分为远程监测组与常规护理组,中位随访 2.8 年,主要终点(全因死亡或心血管原因非计划住院)发生率分别为 42.4% 与 40.8%,无显著差异(HR 1.01,95%CI 0.87-1.18,P=0.87),远程监测未改善结局。

要点

  • 远程监测组主要终点发生率为42.4%,常规护理组为40.8%,两组无显著差异。
  • 全因死亡、心血管死亡及非计划住院等次要终点两组均无显著差异。
  • 远程监测采用每周下载和规范化随访流程,患者依从性高,脱落率仅4.3%。

核心结论

  • 对于心衰合并心脏植入式电子设备的患者,每周下载数据的远程监测加规范化随访未改善临床结局。

研究设计与样本

  • 多中心随机对照试验,纳入1650例心衰合并心脏植入式电子设备的患者,随机分为远程监测组与常规护理组,中位随访2.8年。

主要发现

  • 主要终点(全因死亡或心血管原因非计划住院)发生率远程监测组42.4%,常规护理组40.8%,HR 1.01(95%CI 0.87-1.18),P=0.87。
  • 所有次要终点及主要终点各组分的时间均无显著组间差异。

临床怎么用

  • 对于心衰合并心脏植入式电子设备的患者,不应仅依赖每周下载的远程监测加规范化随访来期望改善预后。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Remote management of heart failure using implantable electronic devices (REM-HF) aimed to assess the clinical and cost-effectiveness of remote monitoring (RM) of heart failure in patients with cardiac implanted electronic devices (CIEDs). METHODS AND RESULTS: Between 29 September 2011 and 31 March 2014, we randomly assigned 1650 patients with heart failure and a CIED to active RM or usual care (UC). The active RM pathway included formalized remote follow-up protocols, and UC was standard practice in nine recruiting centres in England. The primary endpoint in the time to event analysis was the 1st event of death from any cause or unplanned hospitalization for cardiovascular reasons. Secondary endpoints included death from any cause, death from cardiovascular reasons, death from cardiovascular reasons and unplanned cardiovascular hospitalization, unplanned cardiovascular hospitalization, and unplanned hospitalization. REM-HF is registered with ISRCTN (96536028). The mean age of the population was 70 years (range 23-98); 86% were male. Patients were followed for a median of 2.8 years (range 0-4.3 years) completing on 31 January 2016. Patient adherence was high with a drop out of 4.3% over the course of the study. The incidence of the primary endpoint did not differ significantly between active RM and UC groups, which occurred in 42.4 and 40.8% of patients, respectively [hazard ratio 1.01; 95% confidence interval (CI) 0.87-1.18; P = 0.87]. There were no significant differences between the two groups with respect to any of the secondary endpoints or the time to the primary endpoint components. CONCLUSION: Among patients with heart failure and a CIED, RM using weekly downloads and a formalized follow up approach does not improve outcomes.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Morgan JM, Kitt S, Gill J, et al. Remote management of heart failure using implantable electronic devices. Eur Heart J. 2017. PMID: 28575235. doi:10.1093/eurheartj/ehx227

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。