文献速递心力衰竭与心肌病瓣膜病与结构性心脏病

低心室腔僵硬度识别Fontan循环中高风险偏心性重构表型:FORCE注册分析

Low Ventricular Chamber Stiffness Identifies a High-Risk Eccentric Remodeling Phenotype in the Fontan Circulation: A FORCE Registry Analysis.
PubMed 文献 · Circulation · 2026-08-28

本研究基于FORCE注册(814例Fontan患者,中位年龄14.7岁),用单次心搏舒张末期压力-容积关系重建计算心室腔僵硬度指数β并标准化为Z评分。中位随访2.7年,较低的β Z评分独立预测不良结局(校正HR 1.30/1-SD下降,95%CI 1.04-1.61),并与右心室优势、偏心性重构伴射血分数降低、侧支血流增加等相关。结论与既往假设相反:较低而非较高的心室腔僵硬度与不良Fontan结局相关,提示高顺应性伴心室扩张表型。

要点

  • 低β Z评分(高顺应性)独立预测Fontan不良结局,而非高僵硬度。
  • β Z评分<-0.71、β<0.025 mL-1或BSA指数化EDV>103 mL/m2对不良结局区分度 modest(AUC 0.59)。
  • 低β Z评分与右心室优势、偏心性重构、射血分数降低及症状负担增加相关。

核心结论

  • 在FORCE队列中,较低而非较高的心室腔僵硬度与不良Fontan结局相关,识别出高顺应性伴心室扩张和偏心性重构的表型。
  • Fontan循环衰竭可能更多与这种重构表型相关,而非进行性心室僵化。

研究设计与样本

  • FORCE注册(Fontan Outcomes Registry Using Clinical Examinations)回顾性分析,纳入814例Fontan患者,中位年龄14.7岁。
  • 利用配对导管检查和心血管磁共振数据,通过单次心搏舒张末期压力-容积关系重建计算僵硬度指数β,并标准化为体表面积和性别校正的Z评分。

主要发现

  • 中位β为0.034 mL-1(范围0.025-0.046)。
  • 较低β Z评分与右心室优势、偏心性重构伴射血分数降低、侧支血流和心内再循环增加、症状负担更重及心律失常患病率更高相关,尽管充盈压力相似。
  • 中位随访2.7年(范围0.9-6.1年),较低β Z评分独立预测复合不良结局(校正HR 1.30/1-SD下降,95%CI 1.04-1.61)。
  • β Z评分<-0.71、β<0.025 mL-1或BSA指数化舒张末期容积>103 mL/m2对不良结局的区分度相似且 modest(AUC 0.59),在右心室优势者中区分度更高。

临床怎么用

  • 评估Fontan患者时,低心室腔僵硬度(高顺应性)伴心室扩张和偏心性重构应被视为高风险表型。
  • β Z评分、β值或BSA指数化EDV可能有助于风险分层,但区分度有限(AUC 0.59),需结合其他临床指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rising end-diastolic pressure in patients with a Fontan circulation has led to the hypothesis that circulatory failure is driven by progressive ventricular stiffening. However, end-diastolic pressure is influenced by loading conditions and extracardiac constraint and may not accurately reflect chamber stiffness. We aimed to characterize ventricular chamber stiffness using the end-diastolic pressure-volume relationship and examine its clinical and prognostic significance in patients with a Fontan circulation. METHODS: In the FORCE registry (Fontan Outcomes Registry Using Clinical Examinations), chamber stiffness was quantified with the exponential coefficient β derived from single-beat end-diastolic pressure-volume relationship reconstruction using paired catheterization and cardiovascular magnetic resonance data. The β values were standardized as body surface area- and sex-based Z scores and related to clinical characteristics, ventricular remodeling, and a composite adverse outcome (death, transplantation listing, sustained atrial or ventricular arrhythmias, protein-losing enteropathy, or plastic bronchitis). RESULTS: Among 814 patients (median age, 14.7 years), median β was 0.034 mL-1 (0.025-0.046). Lower β Z score was associated with dominant right ventricle, eccentric remodeling with reduced ejection fraction, increased collateral flow and intracardiac recirculation, greater symptom burden, and higher arrhythmia prevalence, despite similar filling pressures. Over a median follow-up of 2.7 years (0.9-6.1 years), lower β Z score independently predicted adverse outcomes (adjusted hazard ratio, 1.30 per 1-SD decrease [95% CI 1.04-1.61]). A β Z score <-0.71, β<0.025 mL-1, or body surface area-indexed end-diastolic volume >103 mL/m2 showed similarly modest discrimination for adverse outcomes overall (area under the curve, 0.59), with greater discrimination in dominant right ventricles. CONCLUSIONS: Contrary to prevailing assumptions, lower rather than higher chamber stiffness was associated with adverse Fontan outcomes, identifying a high-compliance phenotype characterized by ventricular dilation and eccentric remodeling. These findings suggest that, in the contemporary FORCE cohort, Fontan failure might be more closely associated with this remodeling phenotype than with progressive stiffening.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. Van den Eynde J, Van De Bruaene A, Slesnick T, et al. Low Ventricular Chamber Stiffness Identifies a High-Risk Eccentric Remodeling Phenotype in the Fontan Circulation: A FORCE Registry Analysis. Circulation. 2026. PMID: 42663127. doi:10.1161/CIRCULATIONAHA.126.081043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。