文献速递瓣膜病与结构性心脏病

经股动脉TAVI与外科主动脉瓣置换术的环境影响对比:一项前瞻性生命周期评估

Comparative environmental life cycle assessment between transfemoral transcatheter aortic valve implantation and isolated surgical aortic valve replacement.
PubMed 文献 · Heart · 2026-07-29

该前瞻性单中心观察性研究对比了15例经股动脉TAVI与15例SAVR的术中环境影响,采用生命周期评估量化10类环境指标。结果显示SAVR在所有类别环境影响均更高,碳足迹为181.2 kg CO2-eq,而TF-TAVI为68.6 kg CO2-eq,且TF-TAVI在材料、能源和水消耗上均更少。

要点

  • TF-TAVI碳足迹为SAVR的38%(68.6 vs 181.2 kg CO2-eq)。
  • SAVR材料使用17.7 kg(84%塑料),TF-TAVI为8.7 kg(69%塑料)。
  • SAVR水耗为TF-TAVI的30倍(5800 vs 194 L),主要源于体外循环冷却系统。

核心结论

  • 在全部10个计算的环境影响类别中,SAVR的生命周期影响均大于TF-TAVI。
  • TF-TAVI的碳足迹为SAVR的38%,材料少用51%、能源少用52%、水少用97%。

研究设计与样本

  • 前瞻性、观察性、单中心研究,收集15例TF-TAVI和15例SAVR手术的使用数据。
  • 识别术中所有产品、能源和水消耗,用于综合对比生命周期评估以量化术中环境影响。

主要发现

  • SAVR材料使用量为17.7 kg,TF-TAVI为8.7 kg,其中塑料分别占84%和69%。
  • TF-TAVI电力使用比SAVR少52%,两种干预中能源消耗均以电子设备使用为主。
  • SAVR水消耗为5800 L,TF-TAVI为194 L,SAVR是TF-TAVI的30倍,主要因体外循环加热冷却系统。
  • SAVR碳足迹为181.2 kg CO2-eq,TF-TAVI为68.6 kg CO2-eq。

临床怎么用

  • TF-TAVI在环境影响上优于SAVR,但可通过减少一次性物品、关闭闲置影像系统、引入可重复使用/再制造瓣膜输送系统进一步改善。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Comparisons between transfemoral transcatheter aortic valve implantation (TF-TAVI) and surgical aortic valve replacement (SAVR) in severe aortic stenosis have demonstrated a consistent mortality benefit, lower 1 year costs and greater quality-adjusted life years in favour of TF-TAVI. However, the differences in the environmental impact of these two interventions have not yet been sufficiently investigated. The aim of the present study was to compare the intraprocedural environmental impact of these two procedures and to identify emission hotspots in order to mitigate their environmental impact. METHODS: In this prospective, observational, single-centre study, usage data were collected from 15 TF-TAVI and 15 SAVR procedures. All products, energy and water consumed during the procedures were identified and were used in a comprehensive comparative environmental life cycle assessment to quantify the intraprocedural environmental impact of these two interventions. RESULTS: Material use in SAVR amounted to 17.7 kg compared with 8.7 kg in TF-TAVI, consisting of 84% and 69% plastics, respectively. Electricity use in TF-TAVI was 52% less than in SAVR; in both interventions, energy consumption was dominated by the use of electronic devices. In SAVR, water consumption was 30 times higher than in TF-TAVI (5800 vs 194 L), mainly due to the heating cooling system of the cardiopulmonary bypass in SAVR. In all 10 calculated environmental impact categories, SAVR had a greater life-cycle impact. Its carbon footprint was 181.2 kg CO2-eq, compared with 68.6 kg CO2-eq per TF-TAVI. CONCLUSIONS: TF-TAVI outperformed SAVR in all environmental impact categories and had a carbon footprint of 38% that of SAVR. In TF-TAVI, 51% less material, 52% less energy and 97% less water were used. Despite these impressive results, there is still room for improvement in the environmental impact of TF-TAVI by using fewer disposable items, powering down idle imaging systems and introducing reusable/remanufactured valve delivery systems.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Friedericy HJ, Lustig MJ, de Haes FI, et al. Comparative environmental life cycle assessment between transfemoral transcatheter aortic valve implantation and isolated surgical aortic valve replacement. Heart. 2026. PMID: 42527114. doi:10.1136/heartjnl-2026-328011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。