文献速递冠心病

基于冠状动脉造影的FFR与IMR对冠脉血流动力学异常的诊断价值

[The value of coronary angiography-derived fractional flow reserve and coronary angiography-derived index of microcirculatory resistance in coronary artery hemodynamic evaluation].
PubMed 文献 · Zhonghua Xin Xue Guan Bing Za Zhi · 2025-01-01

本研究为诊断试验,纳入181例接受冠脉造影的冠心病患者,用人工智能基于造影影像测算FFR与IMR,并与导丝测量对比。结果显示造影衍生的FFR与导丝FFR相关系数r=0.78,识别血流动力学异常(FFR≤0.80)的AUC为0.88;造影衍生IMR与导丝IMR相关系数r=0.93,识别微循环功能障碍(IMR≥25)的AUC为0.95,提示两者与有创指标高度相关且诊断价值较高。

要点

  • 造影衍生FFR与导丝FFR正相关(r=0.78,P<0.001),诊断血流动力学异常AUC 0.88。
  • 造影衍生IMR与导丝IMR正相关(r=0.93,P<0.001),诊断微循环功能障碍AUC 0.95。
  • 造影衍生IMR识别微循环功能障碍的阴性预测值达96.3%,有助于排除。

核心结论

  • 基于冠状动脉造影的FFR和IMR与导丝测量值呈强正相关,对冠状动脉血流动力学和微循环功能异常具有较高诊断价值。

研究设计与样本

  • 诊断试验,纳入2021年12月至2022年6月三家医院接受冠状动脉造影的拟诊或确诊冠心病患者181例,年龄(60.6±8.8)岁,女性62例(34.3%),共181支目标血管。
  • 入组患者均成功完成导丝FFR及导丝IMR检测;核心实验室用人工智能基于造影影像测算目标血管FFR和IMR。
  • 采用Spearman相关分析评价造影衍生FFR与导丝FFR、造影衍生IMR与导丝IMR的相关性。

主要发现

  • 造影衍生FFR与导丝FFR呈正相关(r=0.78,P<0.001)。
  • 造影衍生IMR与导丝IMR呈正相关(r=0.93,P<0.001)。

关键数值与推荐

  • 以导丝FFR≤0.80定义冠状动脉血流动力学异常;造影衍生FFR识别该异常的准确性89.0%、灵敏度88.8%、特异度89.1%、阳性预测值88.8%、阴性预测值89.1%、AUC 0.88。
  • 以IMR≥25定义微循环功能障碍;造影衍生IMR识别该功能障碍的准确性89.5%、灵敏度86.8%、特异度90.2%、阳性预测值70.2%、阴性预测值96.3%、AUC 0.95。

临床怎么用

  • 对于接受冠状动脉造影的患者,可基于造影影像用人工智能测算FFR和IMR,辅助评估冠状动脉血流动力学和微循环功能异常。
  • 造影衍生IMR阴性预测值较高(96.3%),或有助于排除微循环功能障碍,但阳性预测值70.2%需结合临床。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To evaluate the diagnostic value of coronary angiography-derived fractional flow reserve (FFR) and index of microcirculatory resistance (IMR) for identifying coronary functional abnormalities. Methods: This diagnostic study enrolled patients with clinically suspected or diagnosed coronary artery disease who underwent coronary angiography at Beijing Anzhen Hospital, TEDA International Cardiovascular Hospital, and Qilu Hospital of Shandong University between December 2021 and June 2022. All enrolled patients successfully underwent invasive wire-based FFR and IMR measurements during angiography. In a core laboratory, FFR and IMR for the target vessels were measured using artificial intelligence technology based on coronary angiographic images. Spearman correlation analysis was used to evaluate the correlation between angiography-derived FFR and wire-based FFR, and between angiography-derived IMR and wire-based IMR. Coronary hemodynamic abnormality was defined as FFR≤0.80; the diagnostic performance of angiography-derived FFR for identifying this abnormality was evaluated. Microcirculatory dysfunction was defined as IMR≥25; the diagnostic performance of angiography-derived IMR for identifying microcirculatory dysfunction was evaluated. Results: A total of 181 patients, aged (60.6±8.8) years, with 62 (34.3%) females, and 181 target vessels were included in the final analysis. Angiography-derived FFR showed a significant positive correlation with wire-based FFR (r=0.78, P<0.001). For identifying coronary hemodynamic abnormality, angiography-derived FFR showed an accuracy of 89.0%, sensitivity of 88.8%, specificity of 89.1%, positive predictive value (PPV) of 88.8%, negative predictive value (NPV) of 89.1%, and an area under the receiver operating characteristic curve (AUC) of 0.88. Angiography-derived IMR showed a significant positive correlation with wire-based IMR (r=0.93, P<0.001). For identifying microcirculatory dysfunction, angiography-derived IMR demonstrated an accuracy of 89.5%, sensitivity of 86.8%, specificity of 90.2%, PPV of 70.2%, NPV of 96.3%, and an AUC of 0.95. Conclusion: Angiography-derived FFR and IMR exhibit strong correlations with their invasive wire-based counterparts and demonstrate high diagnostic value for assessing coronary hemodynamics and coronary microcirculatory function. 目的: 评价基于冠状动脉造影的血流储备分数(FFR)与微循环阻力指数(IMR)在识别冠状动脉功能学异常方面的诊断价值。 方法: 本研究为诊断试验,纳入2021年12月至2022年6月就诊于首都医科大学附属北京安贞医院、泰达国际心血管病医院及山东大学齐鲁医院,接受冠状动脉造影检查的拟诊或确诊冠心病的患者。入组患者在造影术中均成功接受了导丝FFR及导丝IMR检测。在核心实验室中,基于人工智能技术利用冠状动脉造影影像测算目标血管的FFR以及IMR。采用Spearman相关分析探讨基于冠状动脉造影的FFR与FFR以及基于冠状动脉造影的IMR与IMR之间的相关性。将FFR≤0.8定义为冠状动脉血流动力学异常,评价基于冠状动脉造影的FFR在识别冠状动脉血流动力学异常方面的诊断效能。将IMR≥25定义为微循环功能障碍,评价基于冠状动脉造影的IMR在识别冠状动脉微循环功能障碍方面的诊断效能。 结果: 共纳入181例患者,年龄(60.6±8.8)岁,其中女性62例(34.3%),共181支血管被纳入最终的分析。基于冠状动脉造影的FFR与FFR呈正相关(r=0.78,P<0.001);其识别冠状动脉血流动力学异常的准确性、灵敏度、特异度、阳性预测值、阴性预测值分别为89.0%、88.8%、89.1%、88.8%和89.1%,受试者工作特征曲线下面积为0.88。基于冠状动脉造影的IMR与IMR呈正相关(r=0.93,P<0.001),基于冠状动脉造影的IMR在识别微循环功能障碍的准确性、灵敏度、特异度、阳性预测值、阴性预测值分别为89.5%、86.8%、90.2%、70.2%、96.3%,曲线下面积为0.95。 结论: 基于冠状动脉造影的FFR与IMR与传统的功能学指标具有良好的相关性,在评估冠状动脉血流动力学以及冠状动脉微循环功能方面表现出较高的诊断价值。.

来源:Zhonghua Xin Xue Guan Bing Za Zhi,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Li Q, Ye YC, et al. [The value of coronary angiography-derived fractional flow reserve and coronary angiography-derived index of microcirculatory resistance in coronary artery hemodynamic evaluation]. Zhonghua Xin Xue Guan Bing Za Zhi. 2025. PMID: 40953989. doi:10.3760/cma.j.cn112148-20250804-00547

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。