文献速递心律失常瓣膜病与结构性心脏病

先天性矫正型大动脉转位患者的心律失常:一项国际研究

Arrhythmias in congenitally corrected transposition of the great arteries: an international study.
PubMed 文献 · Eur Heart J · 2026-01-01

该国际多中心回顾性队列研究纳入29家三级医院(6个国家)1990至2018年的1131例ccTGA患者,随访9.0年,评估房性心律失常、室性心律失常和完全性房室传导阻滞的发生率及相关因素。主要终点10、15、20年累积发生率分别为44.5%、51.0%、58.8%,手术/干预与三种心律失常风险升高相关。

要点

  • ccTGA患者心律失常负担重,主要终点20年累积发生率达58.8%。
  • 手术/干预使房性心律失常风险增加三倍以上(HR 3.01)。
  • 左束支传导阻滞与室性心律失常风险升高相关(HR 4.03)。

核心结论

  • ccTGA患者心律失常负担显著,房性心律失常、室性心律失常和完全性房室传导阻滞发生率均较高。

研究设计与样本

  • 国际多中心回顾性队列研究,纳入6个国家29家三级医院1990至2018年的1131例ccTGA患者,随访9.0(四分位距4.0-17.2)年。

主要发现

  • 主要终点(房性心律失常、室性心律失常或完全性房室传导阻滞复合终点)10、15、20年累积发生率分别为44.5%、51.0%、58.8%。
  • 房性心律失常、室性心律失常和完全性房室传导阻滞的发生率分别为2.1、1.4和2.0例/100人年。
  • 多变量分析中,手术/干预与房性心律失常风险升高相关(HR 3.01,95%CI 1.90-4.78,P < .001)。
  • 手术/干预与室性心律失常(HR 1.73,95%CI 0.98-3.05,P = .003)和完全性房室传导阻滞(HR 3.65,95%CI 2.20-6.05,P < .001)风险升高相关。
  • 左束支传导阻滞与室性心律失常风险升高相关(HR 4.03,95%CI 1.59-10.23,P = .003),右束支传导阻滞与完全性房室传导阻滞风险升高相关(HR 3.71,95%CI 1.81-7.63,P < .001)。

临床怎么用

  • ccTGA患者需长期监测心律失常,尤其关注手术/干预史及束支传导阻滞者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: There is a paucity of data on arrhythmia burden in patients with congenitally corrected transposition of the great arteries (ccTGAs). The present study sought to quantify the incidence of atrial arrhythmia (AA), ventricular arrhythmia (VA), and complete atrioventricular block (CAVB) in patients with ccTGA and identify associated factors. METHODS: An international, multi-centre, retrospective cohort study was conducted in 29 tertiary hospitals (six countries) between 1990 and 2018. Primary analyses consisted of determining the incidence of a combined outcome consisting of AA, VA, or CAVB, along with its individual components. Factors associated with the different types of arrhythmias were assessed by uni-variable and multi-variable Cox regression analyses. RESULTS: A total of 1131 patients with ccTGA were followed for 9.0 (interquartile range 4.0-17.2) years. Cumulative rates of the primary endpoint at 10, 15, and 20 years were 44.5%, 51.0%, and 58.8%, respectively. AA, VA, and CAVB occurred in 2.1, 1.4, and 2.0 cases per 100 person-years, respectively. In multi-variable analyses, surgery/intervention conferred a greater than three-fold higher risk of AA [hazard ratio (HR) 3.01, 95% confidence interval (CI) 1.90-4.78, P < .001]. Furthermore, surgery/intervention was significantly associated with a greater risk of VA (HR 1.73, 95% CI 0.98-3.05, P = .003) and CAVB (HR 3.65, 95% CI 2.20-6.05, P < .001). The left bundle branch block was associated with a higher risk of VA (HR 4.03, 95% CI 1.59-10.23, P = .003) and the right bundle branch block with a higher risk of CAVB (HR 3.71, 95% CI 1.81-7.63, P < .001). CONCLUSIONS: The arrhythmia burden in patients with ccTGA is substantial, with a high incidence of AA, VA, and CAVB.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Sellal JM, Dib N, Karakachoff M, et al. Arrhythmias in congenitally corrected transposition of the great arteries: an international study. Eur Heart J. 2026. PMID: 40679844. doi:10.1093/eurheartj/ehaf466

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。