基于速度编码MRI在6万人中推导轻度主动脉瓣狭窄的新定义阈值
研究利用深度学习在UK Biobank 62,902名参与者中测量主动脉瓣面积、峰值流速和平均压差,并在健康亚组中确定正常与异常血流动力学的自然边界,提出轻度主动脉瓣狭窄的新标准。新标准在NEDA临床队列365,870人中验证,与主动脉瓣置换、房颤、心衰及全因死亡风险升高相关。
要点
- 新标准:峰值流速>1.65 m/s、平均压差>4.9 mm Hg或主动脉瓣面积<2.1 cm²(男)/<1.7 cm²(女)。
- UK Biobank中5.8%参与者符合新标准,与后续主动脉瓣置换风险显著增加相关。
- NEDA队列中符合新标准者全因死亡风险升高(HR 1.25,95%CI 1.24-1.27)。
核心结论
- 研究提出基于速度编码心脏磁共振的轻度主动脉瓣狭窄新阈值,该阈值与不良结局相关并在临床队列中验证。
研究设计与样本
- 研究在UK Biobank 62,902名参与者中利用深度学习模型测量主动脉瓣面积、峰值流速和平均压差,并在NEDA临床队列365,870人中外部验证。
主要发现
- 健康亚组(n=41,859)中正常与异常主动脉瓣血流动力学的自然边界为峰值流速>1.65 m/s、平均压差>4.9 mm Hg或主动脉瓣面积<2.1 cm²(男)/<1.7 cm²(女)。
- UK Biobank全队列中3,676名(5.8%)参与者符合新标准,其后续主动脉瓣置换风险比分别为31.7(轻度)、522.4(中度)和3,057.4(重度),所有P<0.001。
- 平均随访3.9年,符合新标准者相比无主动脉瓣狭窄者,房颤风险(110例事件;HR 1.86;P=1.4×10⁻⁹)和心衰风险(70例事件;HR 2.37;P=5.9×10⁻¹¹)更高。
- NEDA中101,335名经超声心动图按相同标准判定为轻度主动脉瓣狭窄的参与者,全因死亡风险增加(HR 1.25;95%CI 1.24-1.27)。
关键数值与推荐
- 轻度主动脉瓣狭窄新标准:峰值流速>1.65 m/s、平均压差>4.9 mm Hg或主动脉瓣面积<2.1 cm²(男)/<1.7 cm²(女)。
临床怎么用
- 临床可参考新阈值识别轻度主动脉瓣狭窄患者,这类患者房颤、心衰及死亡风险升高,需加强监测与管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mild aortic stenosis (AS) is associated with adverse outcomes but is incompletely defined. OBJECTIVES: The purpose of this study was to examine the epidemiology of AV function measured without clinical indications. METHODS: We developed a deep learning model to measure aortic valve (AV) area, peak velocity, and mean gradient in velocity-encoded cardiac magnetic resonance imaging in 62,902 UK Biobank participants. Study findings were externally validated in NEDA (National Echo Database Australia), a clinical cohort of 365,870 people. RESULTS: From measuring reference ranges of AV function in a healthy subcohort (n = 41,859), we observed a natural boundary between normal and abnormal AV hemodynamics (>95th percentile) that we refer to as "mild ASproposed": peak velocity >1.65 m/s, mean gradient >4.9 mm Hg, or aortic valve area <2.1 cm2 (men) or <1.7 cm2 (women). In the full cohort, 3,676 (5.8%) participants met these novel criteria; the HR for a subsequent AV replacement for each severity category was 31.7 (mild ASproposed), 522.4 (moderate AS), and 3,057.4 (severe AS), all P < 0.001. Over a mean 3.9 years of follow-up, those with mild ASproposed also had a higher risk of atrial fibrillation (110 events; HR: 1.86; P = 1.4 × 10-9) and heart failure (70 events; HR: 2.37; P = 5.9 × 10-11) compared with those without AS. In NEDA, the 101,335 participants with mild ASproposed identified with echocardiography using the same cardiac magnetic resonance imaging-defined criteria had increased all-cause mortality (HR: 1.25; 95% CI: 1.24-1.27). CONCLUSIONS: We report a large-scale study of AV hemodynamics and identify a population threshold between normal and abnormal AV function. Mild AS, as defined by the proposed criteria, was linked to adverse outcomes in the UK Biobank and in NEDA.
引用
- Kany S, Rämö JT, Playford D, et al. New Threshold for Defining Mild Aortic Stenosis Derived From Velocity-Encoded MRI in 60,000 Individuals. J Am Coll Cardiol. 2025. PMID: 40175013. doi:10.1016/j.jacc.2025.01.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。