文献速递心律失常

人工智能应用于单导联动态心电图近期预测持续性室性心律失常

Near-term prediction of sustained ventricular arrhythmias applying artificial intelligence to single-lead ambulatory electrocardiogram.
PubMed 文献 · Eur Heart J · 2025-01-01

BACKGROUND AND AIMS: Accurate near-term prediction of life-threatening ventricular arrhythmias would enable pre-emptive actions to prevent sudden cardiac arrest/death.…

要点

  • 深度学习模型可基于单导联动态心电图前24小时数据预测后续13天持续性室速风险。
  • 模型对快速持续性室速(≥180 b.p.m.)预测准确率约80%,对蜕变为室颤的室速预测准确率90.0%。

核心结论

  • 基于动态单导联心电图的深度学习模型能准确识别近期室性心律失常高风险患者。
  • 模型揭示早期去极化模式可能是室性心律失常事件的潜在决定因素。

研究设计与样本

  • 利用前24小时数据预测后续13天持续性室速发生(主要结局)。

主要发现

  • 特异性固定97.0%时,内部和外部验证集敏感度分别为70.6%和66.1%。
  • 模型对快速持续性室速(≥180 b.p.m.)预测准确率分别为80.7%和81.1%,对蜕变为室颤的室速预测准确率90.0%。
  • 显著性图提示室性早搏负荷和早期去极化时间作为室速预测因子。

临床怎么用

  • 该模型可用于动态心电图数据分析,辅助识别近期持续性室速高风险患者以采取预防措施。
  • 高特异性设定下敏感度约66%-71%,需结合临床综合评估。

局限性

  • 回顾性研究设计。
  • 仅使用单导联动态心电图。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Accurate near-term prediction of life-threatening ventricular arrhythmias would enable pre-emptive actions to prevent sudden cardiac arrest/death. A deep learning-enabled single-lead ambulatory electrocardiogram (ECG) may identify an ECG profile of individuals at imminent risk of sustained ventricular tachycardia (VT). METHODS: This retrospective study included 247 254, 14 day ambulatory ECG recordings from six countries. The first 24 h were used to identify patients likely to experience sustained VT occurrence (primary outcome) in the subsequent 13 days using a deep learning-based model. The development set consisted of 183 177 recordings. Performance was evaluated using internal (n = 43 580) and external (n = 20 497) validation data sets. Saliency mapping visualized features influencing the model's risk predictions. RESULTS: Among all recordings, 1104 (.5%) had sustained ventricular arrhythmias. In both the internal and external validation sets, the model achieved an area under the receiver operating characteristic curve of .957 [95% confidence interval (CI) .943-.971] and .948 (95% CI .926-.967). For a specificity fixed at 97.0%, the sensitivity reached 70.6% and 66.1% in the internal and external validation sets, respectively. The model accurately predicted future VT occurrence of recordings with rapid sustained VT (≥180 b.p.m.) in 80.7% and 81.1%, respectively, and 90.0% of VT that degenerated into ventricular fibrillation. Saliency maps suggested the role of premature ventricular complex burden and early depolarization time as predictors for VT. CONCLUSIONS: A novel deep learning model utilizing dynamic single-lead ambulatory ECGs accurately identifies patients at near-term risk of ventricular arrhythmias. It also uncovers an early depolarization pattern as a potential determinant of ventricular arrhythmias events.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Fiorina L, Carbonati T, Narayanan K, et al. Near-term prediction of sustained ventricular arrhythmias applying artificial intelligence to single-lead ambulatory electrocardiogram. Eur Heart J. 2025. PMID: 40157386. doi:10.1093/eurheartj/ehaf073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。