冠状动脉微血管功能与动脉粥样硬化斑块负荷在INOCA中的关联:CorMicA试验二次分析
本研究基于CorMicA队列151例无阻塞性冠心病患者,分析Gensini评分与冠状动脉微血管功能指标及INOCA内表型的关联。发现CFR、MRR、RRR降低及微血管心绞痛与更高Gensini评分相关,提示INOCA与动脉粥样硬化负荷存在机制联系。
要点
- CFR、MRR、RRR降低与Gensini评分升高独立相关,IMR无显著关联。
- 微血管心绞痛患者Gensini评分高于其他INOCA内表型。
- 结果支持微血管心绞痛患者应强化抗动脉粥样硬化治疗。
核心结论
- CFR、MRR和RRR降低以及微血管心绞痛与冠状动脉粥样硬化斑块负荷增加相关。
研究设计与样本
- CorMicA试验二次分析,纳入151例无血流限制性冠心病患者,中位年龄61岁,73.5%女性。
- 同步行冠状动脉造影和侵入性冠状动脉功能检查,使用热稀释导丝及乙酰胆碱激发试验。
- 基于SYNTAX模型各节段狭窄情况计算Gensini评分,造影分析对生理学结果盲法。
主要发现
- 151例中55.0%患者CFR和/或IMR异常,Gensini评分中位数6.0(IQR 2.5-11.0)。
- CFR(p=0.012)、MRR(p=0.026)、RRR(p=0.026)与Gensini评分单变量相关,IMR(p=0.445)不相关,多变量模型校正后仍显著。
- 不同INOCA内表型Gensini评分:微血管心绞痛7.0(2.5-11.0)、血管痉挛性心绞痛4.5(2.0-10.0)、混合型9.0(5.0-11.5)、非心源性症状3.5(1.5-8.0),Kruskal-Wallis p=0.030。
临床怎么用
- 对微血管心绞痛患者,应考虑评估并管理动脉粥样硬化危险因素。
- CFR、MRR、RRR等微血管功能指标有助于识别斑块负荷较高的INOCA患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The relationship between atherosclerosis and endotypes of myocardial ischaemia with no obstructive coronary artery disease (INOCA) is unclear. We investigated potential associations between cumulative atherosclerotic plaque burden quantified using the Gensini score, novel invasive indices of coronary microvascular function (microvascular resistance reserve (MRR); resistive reserve ratio (RRR)) and related INOCA endotypes. METHODS: Coronary angiography and invasive coronary function tests were simultaneously acquired in the CorMicA cohort. A comprehensive physiological assessment was performed using both a thermodilution-based diagnostic guidewire and intracoronary acetylcholine provocation testing. Angiograms were examined for luminal stenosis in each segment of the SYNTAX coronary model. Cumulative plaque burden was quantified using the Gensini score, which incorporated both the number of diseased coronary segments and stenosis severity. Results were compared with indices of microvascular function and INOCA endotypes. Angiographic analyses were performed blind to coronary physiology findings. RESULTS: In 151 participants (median age 61 years; 73.5% female) without flow-limiting coronary artery disease, medical history included 41.7% smoking, 63.6% hypertension and 19.2% diabetes mellitus. The left anterior descending artery underwent diagnostic guidewire testing in 85.4%, and 55.0% of participants had abnormal coronary flow reserve (CFR) and/or Index of Microcirculatory Resistance (IMR). The median Gensini score was 6.0 (IQR 2.5-11.0). CFR (p=0.012), MRR (p=0.026) and RRR (p=0.026), but not IMR (p=0.445), were univariably associated with raised Gensini scores. These significant effects persisted in multivariable models controlling for potential confounders. Considering INOCA endotypes, Gensini scores differed among participants with microvascular angina (MVA) (7.0 (2.5-11.0)), vasospastic angina (VSA) (4.5 (2.0-10.0)), mixed MVA/VSA (9.0 (5.0-11.5)) and non-cardiac symptoms (3.5 (1.5-8.0)); Kruskal-Wallis p=0.030. CONCLUSIONS: Reduced CFR, MRR and RRR, and MVA were associated with increased coronary atherosclerotic plaque burden, as evidenced by higher Gensini scores. These novel findings provide a mechanistic link between INOCA and cardiovascular events, reinforcing the importance of antiatherosclerosis therapy in patients with MVA.
引用
- Ang DTY, Carberry J, Ford TJ, et al. Coronary microvascular function and atherosclerotic plaque burden in ischaemia and no obstructive coronary arteries: a secondary analysis of the CorMicA trial. Heart. 2025. PMID: 39603791. doi:10.1136/heartjnl-2024-324677
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。