机械循环支持辅助下导管消融血流动力学不稳定室性心动过速的早期经验
该回顾性队列研究纳入15例血流动力学不稳定室性心动过速患者,在机械循环支持下接受导管消融,按治疗目的分为挽救性组8例和预防性组7例。所有患者手术即刻成功,14例使用ECMO支持,12例成功撤机;挽救性组2例在院死亡。中位随访30天,除1例左心室辅助装置患者出现1次心室颤动外,其余患者未发生恶性室性心律失常。结论认为机械循环支持有助于完成标测和消融。
要点
- 机械循环支持可辅助血流动力学不稳定室速患者完成标测与导管消融,所有15例手术即刻成功。
- 14例患者使用ECMO支持,其中12例成功撤机,6例术后即刻撤机。
- 挽救性组2例在院死亡,分别因顽固性心力衰竭和脑出血。
核心结论
- 机械循环支持有助于血流动力学不稳定室速患者完成激动标测及精准消融;尤其在急诊条件下,是药物治疗无效患者得以行急诊导管消融的唯一支持手段。
研究设计与样本
- 回顾性队列研究,纳入2021年8月至2023年12月于首都医科大学附属北京安贞医院在机械循环支持下接受导管消融的血流动力学不稳定室速患者15例,按治疗目的分为挽救性组8例和预防性组7例。
主要发现
- 所有15例患者手术即刻成功;1例(挽救性组)植入左心室辅助装置,其余14例采用体外膜肺氧合支持。
- 12例患者临床和血流动力学稳定后撤机,其中6例术后即刻撤机,其余在术后2.0(2.5)d撤机。
- 挽救性组2例在院期间分别因顽固性心力衰竭和脑出血死亡。
- 中位随访30 d(1 d至12个月),植入左心室辅助装置的1例患者在出院后第6个月出现1次心室颤动,经抗心律失常药物治疗后未再出现心室颤动和(或)室速;其余12例随访患者未发生恶性室性心律失常。
临床怎么用
- 对于血流动力学不稳定室速患者,可考虑在机械循环支持下进行标测和导管消融,以维持围术期血流动力学稳定。
- 挽救性治疗组患者院内死亡风险较高,需密切监测心力衰竭和出血等并发症。
局限性
- 回顾性单中心研究,样本量仅15例,随访时间中位30 d,证据强度有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To explore the role of mechanical hemodynamic support (MHS) in mapping and catheter ablation of patients with hemodynamically unstable ventricular tachycardia (VT), report single-center experience in a cohort of consecutive patients receiving VT ablation during MHS therapy, and provide evidence-based medical evidence for clinical practice. Methods: This was a retrospective cohort study. Patients with hemodynamically unstable VT who underwent catheter ablation with MHS at Beijing Anzhen Hospital, Capital Medical University between August 2021 and December 2023 were included. Patients were divided into rescue group and preventive group according to the purpose of treatment. Their demographic data, periprocedural details, and clinical outcomes were collected and analyzed. Results: A total of 15 patients with hemodynamically unstable VT were included (8 patients in the rescue group and 7 patients in the preventive group). The acute procedure was successful in all patients. One patient in the rescue group had surgical left ventricular assist device (LVAD) implantation, remaining 14 patients received extracorporeal membrane oxygenation (ECMO) for circulation support. ECMO decannulation was performed in 12 patients due to clinical and hemodynamic stability, of which 6 patients were decannulation immediately after surgery and the remaining patients were decannulation at 2.0 (2.5) d after surgery. Two patients in the rescue group died during the index admission due to refractory heart failure and cerebral hemorrhage. During a median follow-up of 30 d (1 d to 12 months), one patient with LVAD had one episode of ventricular fibrillation at 6 months after discharge, and no further episodes of ventricular fibrillation and/or VT occurred after treatment with antiarrhythmic drugs. No malignant ventricular arrhythmia occurred in the remaining 12 patients who were followed up. Conclusions: MHS contributes to the successful completion of mapping and catheter ablation in patients with hemodynamically unstable VT, providing desirable hemodynamic status for emergency and elective conditions. 目的: 探讨循环辅助支持在血流动力学不稳定的室性心动过速患者的标测及导管消融治疗中的作用,对该类患者的单中心经验进行总结分析,为临床提供循证医学证据。 方法: 该研究为回顾性队列研究。纳入2021年8月至2023年12月于首都医科大学附属北京安贞医院在循环辅助支持下接受导管消融手术的血流动力学不稳定的室性心动过速患者,根据治疗目的分为挽救性治疗组和预防性治疗组,对两组患者的人口学资料、围术期管理、导管消融情况及临床结局进行总结。 结果: 共纳入15例血流动力学不稳定的室性心动过速患者(挽救性治疗组8例,预防性治疗组7例),所有患者手术均获得即刻成功。1例患者(挽救性治疗组)植入左心室辅助装置,其余14例患者均采用体外膜肺氧合进行循环支持。术后在院期间,12例患者临床和血流动力学稳定,进行了体外膜肺氧合撤机,其中6例术后即刻撤机,其余在术后2.0(2.5)d撤机。挽救性治疗组中2例患者在院期间分别因顽固性心力衰竭和脑出血死亡。在30 d(1 d至12个月)的随访中,植入左心室辅助装置的1例患者在出院后第6个月出现1次心室颤动,经抗心律失常药物治疗后未再出现心室颤动和(或)室性心动过速。其余12例患者术后均未发生恶性室性心律失常事件。 结论: 循环辅助支持有助于血流动力学不稳定的室性心动过速患者完成激动标测及精准消融;尤其是急诊条件下,循环辅助支持是药物治疗无效的血流动力学不稳定的室性心动过速患者得以行急诊导管消融的唯一支持手段。.
引用
- Li MM, Yang Y, Long DY, et al. [Early experience with mechanical hemodynamic support for catheter ablation of malignant ventricular tachycardia]. Zhonghua Xin Xue Guan Bing Za Zhi. 2024. PMID: 39019825. doi:10.3760/cma.j.cn112148-20240410-00194
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。