三维心脏磁共振可识别法洛四联症中的缓慢传导解剖峡部
本研究在修复后的法洛四联症患者中,通过将右心室电解剖标测与三维晚期钆增强心脏磁共振(3D-LGE-CMR)配准,确定异常心肌的高信号阈值,并评估3D-LGE-CMR无创识别缓慢传导解剖峡部(SCAI)的诊断性能。
要点
- 3D-LGE-CMR可高敏感度和特异度无创识别法洛四联症患者的SCAI。
- 高信号阈值定为最大信号强度的42%。
核心结论
- 3D-LGE-CMR能准确识别法洛四联症修复术后患者的缓慢传导解剖峡部,可能改善无创风险分层和侵入性电解剖标测的患者选择。
研究设计与样本
- 连续纳入接受右心室电解剖标测和3D-LGE-CMR的法洛四联症患者,推导队列48例(34±16岁),验证队列53例(36±18岁)。
- 通过右心室电解剖标测与3D-LGE-CMR配准直接比较双极电压与信号强度,确定异常心肌的高信号阈值。
主要发现
- 推导队列中,电解剖标测识别的107个解剖峡部中,78个为正常传导,22个为SCAI,7个为阻滞。
- 验证队列中,124个解剖峡部中,85个为正常传导,36个为SCAI,3个为阻滞。
- 3D-LGE-CMR识别SCAI或阻滞AI的敏感度和特异度在推导队列为100%和90%,在验证队列为95%和91%。
关键数值与推荐
- 高信号阈值确定为最大信号强度的42%。
- 3D-LGE-CMR识别SCAI或阻滞AI的敏感度100%、特异度90%(推导队列)。
- 3D-LGE-CMR识别SCAI或阻滞AI的敏感度95%、特异度91%(验证队列)。
临床怎么用
- 对于修复后的法洛四联症患者,可考虑使用3D-LGE-CMR无创识别SCAI,以辅助风险分层和筛选适合侵入性电解剖标测的患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Patients with repaired tetralogy of Fallot remain at risk of life-threatening ventricular tachycardia related to slow-conducting anatomical isthmuses (SCAIs). Preventive ablation of SCAI identified by invasive electroanatomical mapping is increasingly performed. This study aimed to non-invasively identify SCAI using 3D late gadolinium enhancement cardiac magnetic resonance (3D-LGE-CMR). METHODS: Consecutive tetralogy of Fallot patients who underwent right ventricular electroanatomical mapping (RV-EAM) and 3D-LGE-CMR were included. High signal intensity threshold for abnormal myocardium was determined based on direct comparison of bipolar voltages and signal intensity by co-registration of RV-EAM with 3D-LGE-CMR. The diagnostic performance of 3D-LGE-CMR to non-invasively identify SCAI was determined, validated in a second cohort, and compared with the discriminative ability of proposed risk scores. RESULTS: The derivation cohort consisted of 48 (34 ± 16 years) and the validation cohort of 53 patients (36 ± 18 years). In the derivation cohort, 78 of 107 anatomical isthmuses (AIs) identified by EAM were normal-conducting AI, 22 were SCAI, and 7 blocked AI. High signal intensity threshold was 42% of the maximal signal intensity. The sensitivity and specificity of 3D-LGE-CMR for identifying SCAI or blocked AI were 100% and 90%, respectively. In the validation cohort, 85 of 124 AIs were normal-conducting AI, 36 were SCAI, and 3 blocked AI. The sensitivity and specificity of 3D-LGE-CMR were 95% and 91%, respectively. All risk scores showed an at best modest performance to identify SCAI (area under the curve ≤ .68). CONCLUSIONS: 3D late gadolinium enhancement cardiac magnetic resonance can identify SCAI with excellent accuracy and may refine non-invasive risk stratification and patient selection for invasive EAM in tetralogy of Fallot.
引用
- Kimura Y, Wallet J, Bouyer B, et al. Three-dimensional cardiac magnetic resonance allows the identification of slow-conducting anatomical isthmuses in tetralogy of Fallot. Eur Heart J. 2024. PMID: 38748258. doi:10.1093/eurheartj/ehae268
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。