文献速递心律失常冠心病

二尖瓣峡部脉冲场消融与射频消融中冠状动脉痉挛的比较

Coronary Artery Spasm During Pulsed Field vs Radiofrequency Catheter Ablation of the Mitral Isthmus.
PubMed 文献 · JAMA Cardiol · 2024-01-01

这项前瞻性队列研究在房颤导管消融中比较了二尖瓣峡部相邻消融时脉冲场消融(PFA)与射频消融(RFA)引发左回旋支动脉痉挛的发生率和严重程度。结果显示PFA组痉挛常见(41.2%),而RFA组无痉挛发生,且多数痉挛为亚临床型。

要点

  • 二尖瓣峡部PFA消融时左回旋支痉挛发生率为41.2%,RFA组为0%。
  • 消融线位于上方时痉挛发生率更高(77.8%),位于下方时为0%。
  • 多数痉挛(90%)为亚临床型,仅20%需硝酸甘油处理。

核心结论

  • 二尖瓣峡部PFA消融时左回旋支动脉痉挛常见,而RFA未发生,但痉挛多为亚临床型。

研究设计与样本

  • 前瞻性队列研究,2022年单中心连续纳入26例首次接受二尖瓣峡部PFA(n=17)或RFA(n=9)的房颤消融成人患者。

主要发现

  • PFA组7/17(41.2%)发生冠状动脉痉挛,RFA组0/9发生。
  • PFA组中消融线位于上方时痉挛发生率为7/9(77.8%),位于下方时为0/8。
  • RFA失败后交叉至PFA的5例患者中3例(60%)发生痉挛。
  • 10次痉挛事件中9次(90%)为亚临床型,2次(20%)需硝酸甘油。
  • 痉挛缓解中位时间为5(范围5-25)分钟。

临床怎么用

  • 二尖瓣峡部PFA消融时需警惕左回旋支痉挛,尤其消融线位于上方时。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: In treating atrial fibrillation, pulsed field ablation (PFA) is a novel energy modality with comparable efficacy to conventional thermal ablation, such as radiofrequency ablation (RFA), but with the benefit of some preferentiality to myocardial tissue ablation. Studies have demonstrated important safety advantages, including the absence of esophageal injury or pulmonary vein stenosis and only rare phrenic nerve injury. However, there is emerging evidence of coronary artery vasospasm provoked by PFA. OBJECTIVE: To compare the incidence and severity of left circumflex arterial vasospasm between PFA and RFA during adjacent ablation along the mitral isthmus. DESIGN, SETTING, AND PARTICIPANTS: This prospective cohort study enrolled consecutive adult patients receiving first-ever PFA or RFA of the mitral isthmus during catheter ablation of atrial fibrillation in 2022 with acute follow-up at a single referral European center. EXPOSURE: A posterolateral mitral isthmus line was created using either a multielectrode pentaspline PFA catheter (endocardial ablation) or a saline-irrigated RFA catheter. Simultaneous diagnostic coronary angiography was performed before, during, and after catheter ablation. Nitroglycerin was planned for spasm persisting beyond 20 minutes or for significant electrocardiographic changes. MAIN OUTCOMES AND MEASURES: The frequency and severity of left circumflex arterial vasospasm was assessed and monitored, as were time to remission and any need for nitroglycerin administration. RESULTS: Of 26 included patients, 19 (73%) were male, and the mean (SD) age was 65.5 (9.3) years. Patients underwent either PFA (n = 17) or RFA (n = 9) along the mitral isthmus. Coronary spasm was observed in 7 of 17 patients (41.2%) undergoing PFA: in 7 of 9 (77.8%) when the mitral isthmus ablation line was situated superiorly and in 0 of 8 when situated inferiorly. Conversely, coronary spasm did not occur in any of the 9 patients undergoing RFA. Of 5 patients in whom crossover PFA was performed after RFA failed to achieve conduction block, coronary spasm occurred in 3 (60%). Most instances of spasm (9 of 10 [90%]) were subclinical, with 2 (20%) requiring nitroglycerin administration. The median (range) time to resolution of spasm was 5 (5-25) minutes. CONCLUSION AND RELEVANCE: When creating a mitral isthmus ablation line during catheter ablation of atrial fibrillation, adjacent left circumflex arterial vasospasm frequently occurred with PFA and not RFA but was typically subclinical.

来源:JAMA Cardiol,查看原文。版权归原作者所有。

引用

  1. Zhang C, Neuzil P, Petru J, et al. Coronary Artery Spasm During Pulsed Field vs Radiofrequency Catheter Ablation of the Mitral Isthmus. JAMA Cardiol. 2024. PMID: 38019505. doi:10.1001/jamacardio.2023.4405

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。