增强现实眼镜辅助心力衰竭患者射血分数视觉估测的准确性
一项前瞻性随机交叉模拟研究纳入22名急诊医师,比较使用与不使用增强现实(AR)眼镜估测心力衰竭患者超声心动图视频左心室射血分数(LVEF)的准确性。结果显示使用AR眼镜的组内相关系数(ICC)为0.969(95% CI 0.966–0.971),显著高于不使用眼镜的0.705(95% CI 0.681–0.727),在低年资住院医师中提升最为明显。
要点
- AR眼镜可提高急诊医师视觉估测LVEF的准确性。
- 低年资住院医师获益最大,ICC从0.568提升至0.963。
- 高年资医师使用AR眼镜后ICC亦提升至0.972–0.973。
核心结论
- AR眼镜有助于测量LVEF,对视觉估测经验较少者帮助更大。
研究设计与样本
- 前瞻性随机交叉模拟研究,22名急诊医师参与,随机分两组分别使用或不使用AR眼镜估测心衰患者超声心动图视频的LVEF,洗脱期后交叉。
主要发现
- 全体参与者使用AR眼镜的ICC为0.969(95% CI 0.966–0.971),不使用为0.705(95% CI 0.681–0.727)。
- 第一、二年住院医师不使用眼镜ICC为0.568(95% CI 0.508–0.621),使用为0.963(95% CI 0.958–0.968)。
- 第三、四年住院医师不使用眼镜ICC为0.754(95% CI 0.720–0.784),使用为0.972(95% CI 0.958–0.968)。
- 主治医师不使用眼镜ICC为0.807(95% CI 0.775–0.834),使用为0.973(95% CI 0.969–0.977)。
临床怎么用
- 在心力衰竭患者超声心动图LVEF视觉估测中,可考虑使用AR眼镜辅助以提高准确性,尤其适合经验较少的医师。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Left ventricular ejection fraction (LVEF) is measured to assess haemodynamic status and cardiac function. It may be difficult to accurately measure in patients with heart failure (HF) as they are often poorly echogenic. The augmented reality (AR) technology is expected to provide real-time guidance that will enable more accurate measurements. METHODS: A prospective, randomised, case-crossover simulation study was conducted to confirm the effect of AR glasses on echocardiographic interpretation in patients with HF. 22 emergency physicians participated. The participants were randomly assigned to two groups. Group A estimated the visual ejection fraction of echocardiographic video clips without the AR glasses, while group B estimated them with glasses. After a washout period, the two groups crossed over. The estimates were then compared with the ejection fraction measurements obtained by echocardiologists; intraclass correlation coefficient (ICC) was calculated. RESULTS: The ICC with glasses (0.969, 95% CI 0.966 to 0.971) was higher than without glasses (0.705, 95% CI 0.681 to 0.727) among all participants. In the subgroup analysis, the first-year and second-year residents showed the most significant difference, with an ICC of 0.568 (95% CI 0.508 to 0.621) without glasses compared with 0.963 (95% CI 0.958 to 0.968) with glasses. For the third-year and fourth-year residents group, the ICC was 0.754 (95% CI 0.720 to 0.784) without glasses and 0.972 (95% CI 0.958 to 0.968) with glasses. Among the group of attending physicians, the ICC was 0.807 (95% CI 0.775 to 0.834) without glasses and 0.973 (95% CI 0.969 to 0.977) with glasses. CONCLUSIONS: AR glasses could be helpful in measuring LVEF and could be more helpful to those with little visual estimation experience.
引用
- Choi S, Nah S, Cho YS, et al. Accuracy of visual estimation of ejection fraction in patients with heart failure using augmented reality glasses. Heart. 2024. PMID: 37940379. doi:10.1136/heartjnl-2023-323067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。