窦房结功能障碍中最小化心房起搏不减少房颤发生:一项随机试验
这项全国性随机对照试验纳入540例有首次起搏器植入指征的窦房结功能障碍患者,比较DDD-40(基础频率40次/分、非频率适应性)与DDDR-60(基础频率60次/分、频率适应性)对房颤发生的影响。随访2年,主要终点(首次房颤>6分钟)两组均为46%,无差异;但DDD-40组晕厥或先兆晕厥风险更高。
要点
- 最小化心房起搏(DDD-40)未降低窦房结功能障碍患者的房颤发生率。
- DDD-40组晕厥或先兆晕厥风险较DDDR-60组增加71%。
- 房颤>6小时、>24小时、持续性房颤及电复律两组均无差异。
核心结论
- 在窦房结功能障碍患者中,最小化心房起搏不减少房颤发生。
- 基础频率40次/分且非频率适应性起搏与晕厥或先兆晕厥风险增加相关。
研究设计与样本
- 全国性随机对照试验,纳入540例窦房结功能障碍且有首次起搏器植入指征的患者。
- 随机分为DDD-40组(基础频率40次/分、非频率适应性)和DDDR-60组(基础频率60次/分、频率适应性),远程监测随访2年。
主要发现
- 心房起搏中位百分比:DDD-40组1%,DDDR-60组49%。
- 房颤>6小时、>24小时、持续性房颤或房颤电复律两组无差异。
临床怎么用
- 对于窦房结功能障碍需首次起搏器植入的患者,不应仅为减少房颤而将起搏模式设为DDD-40。
- 选择DDD-40模式时需权衡晕厥或先兆晕厥风险增加。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: High percentages of atrial pacing have been associated with an increased risk of atrial fibrillation. This study is aimed at evaluating whether atrial pacing minimization in patients with sinus node dysfunction reduces the incidence of atrial fibrillation. METHODS: In a nationwide, randomized controlled trial, 540 patients with sinus node dysfunction and an indication for first pacemaker implantation were assigned to pacing programmed to a base rate of 60 bpm and rate-adaptive pacing (DDDR-60) or pacing programmed to a base rate of 40 bpm without rate-adaptive pacing (DDD-40). Patients were followed on remote monitoring for 2 years. The primary endpoint was time to first episode of atrial fibrillation longer than 6 min. Secondary endpoints included longer episodes of atrial fibrillation, and the safety endpoint comprised a composite of syncope or presyncope. RESULTS: The median percentage of atrial pacing was 1% in patients assigned to DDD-40 and 49% in patients assigned to DDDR-60. The primary endpoint occurred in 124 patients (46%) in each treatment group (hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.76-1.25, P = .83). There were no between-group differences in atrial fibrillation exceeding 6 or 24 h, persistent atrial fibrillation, or cardioversions for atrial fibrillation. The incidence of syncope or presyncope was higher in patients assigned to DDD-40 (HR 1.71, 95% CI 1.13-2.59, P = .01). CONCLUSIONS: Atrial pacing minimization in patients with sinus node dysfunction does not reduce the incidence of atrial fibrillation. Programming a base rate of 40 bpm without rate-adaptive pacing is associated with an increased risk of syncope or presyncope.
引用
- Kronborg MB, Frausing MHJP, Malczynski J, et al. Atrial pacing minimization in sinus node dysfunction and risk of incident atrial fibrillation: a randomized trial. Eur Heart J. 2023. PMID: 37638973. doi:10.1093/eurheartj/ehad564
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。