文献速递心律失常瓣膜病与结构性心脏病

三维双曲面电路中固定传导阻滞线界定的人类室性心动过速

Identification of Human Ventricular Tachycardia Demarcated by Fixed Lines of Conduction Block in a 3-Dimensional Hyperboloid Circuit.
PubMed 文献 · Circulation · 2023-08-28

本研究在106例瘢痕相关室性心动过速(VT)消融患者中,将175个VT激动标测图与窦性心律下等时晚激动标测图进行关联。结果显示,74%的VT峡部边界可在基线心律或差异起搏下识别为固定传导阻滞线(LOB),且三维VT的深度边界与LOB共定位达79%。起搏标测可揭示隐匿性LOB,支持VT电路呈三维双曲面结构,消融可简化为针对窦性心律下LOB两侧。

要点

  • 多数VT电路边界可在窦性心律下表现为固定传导阻滞线。
  • 瘢痕内起搏可揭示基线未显现的隐匿性传导阻滞线。
  • 消融可简化为针对识别的传导阻滞线两侧进行。

核心结论

  • 大多数VT电路边界可在窦性心律下通过自身或起搏激动识别为固定传导阻滞线。
  • 在瘢痕基质内起搏分析激动可揭示先前被认为是功能性的隐匿性传导阻滞线。
  • 来自心肌表面的传导阻滞线常与壁内传导相关,支持三维双曲面VT电路结构的存在。

研究设计与样本

  • 研究纳入106例来自3个中心的瘢痕相关VT消融患者,其中42%为非缺血性心肌病。
  • 共分析175个VT激动标测图,并与基线心律下等时晚激动标测图进行关联。
  • 显著传导阻滞线定义为基线心律下具有分裂电位(≥20 ms等电位段)的减速区。
  • 在减速区内进行起搏(≥600 ms)以揭示基线未显现的隐匿性传导阻滞线。

主要发现

  • 在202个基线心律下分析的减速区中,47%存在显著传导阻滞线。
  • 对38个无显著传导阻滞线的减速区进行差异起搏,84%暴露了隐匿性传导阻滞线。
  • 在152个VT激动标测图(二维53个,三维99个)中,69%的二维侧边界与传导阻滞线共定位。
  • 三维VT的深度边界与传导阻滞线共定位达79%。
  • 在峡部区域与U形传导阻滞线共定位的VT电路(n=28)中,该边界在二维和三维中均作为两侧边界。

关键数值与推荐

  • 显著传导阻滞线定义为基线心律下具有分裂电位(≥20 ms等电位段)的减速区。
  • 差异起搏在减速区内以≥600 ms的周期进行,以揭示隐匿性传导阻滞线。

临床怎么用

  • 导管消融可简化为针对窦性心律下识别的传导阻滞线两侧进行。
  • 在瘢痕基质内进行起搏激动分析有助于揭示隐匿性传导阻滞线,指导消融。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.

来源:Circulation,查看原文。版权归原作者所有。

引用

  1. Nishimura T, Shatz N, Weiss JP, et al. Identification of Human Ventricular Tachycardia Demarcated by Fixed Lines of Conduction Block in a 3-Dimensional Hyperboloid Circuit. Circulation. 2023. PMID: 37638389. doi:10.1161/CIRCULATIONAHA.123.065525

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。