文献速递冠心病血脂与心血管预防

声学评分对疑似冠心病患者的可能性重分类

Likelihood reclassification by an acoustic-based score in suspected coronary artery disease.
PubMed 文献 · Heart · 2023-07-27

研究纳入1683例稳定心绞痛并转诊冠状动脉CT血管造影的患者,采用声学CAD评分设备进行心音分析,评估其诊断效能及与ESC-PTP联合的双重可能性策略的重分类潜力。结果显示,以CAD评分≤20排除梗阻性CAD的敏感度为85.4%,阴性预测值95.4%;在ESC-PTP 5%至<15%的患者中,48%被降为极低可能性,该组梗阻性CAD患病率为3.5%。

要点

  • 声学CAD评分≤20排除梗阻性CAD的敏感度85.4%、阴性预测值95.4%。
  • ESC-PTP 5%至<15%患者中48%经声学评分降为极低可能性。
  • 降类后极低可能性组梗阻性CAD患病率仅3.5%。

核心结论

  • 在低CAD可能性患者中,声学排除设备可明显降低可能性等级,有望补充现有评估策略以避免不必要检查。

研究设计与样本

  • 连续纳入1683例稳定心绞痛并转诊冠状动脉CTA的患者,接受声学CAD评分设备心音分析。
  • 冠状动脉CTA显示任何冠脉节段≥50%狭窄者转诊行有创冠状动脉造影及血流储备分数检查。
  • 预设CAD评分≤20用于排除梗阻性CAD。

主要发现

  • 439例(26%)冠状动脉CTA显示≥50%狭窄。
  • 后续有创冠状动脉造影及血流储备分数显示199例(11.8%)存在梗阻性CAD。
  • CAD评分≤20排除梗阻性CAD:敏感度85.4%(95%CI 79.7至90.0),特异度40.4%(95%CI 37.9至42.9)。
  • 阳性预测值16.1%(95%CI 13.9至18.5),阴性预测值95.4%(95%CI 93.4至96.9)。
  • 在ESC-PTP 5%至<15%患者中应用该切点,316例(48%)降为极低可能性,该组梗阻性CAD患病率3.5%。

关键数值与推荐

  • CAD评分≤20作为排除梗阻性CAD的预设切点。
  • ESC-PTP 5%至<15%定义为低预概率,该组经声学评分重分类后极低可能性组梗阻性CAD患病率3.5%。

临床怎么用

  • 对ESC-PTP低预概率(5%至<15%)的稳定心绞痛患者,可考虑联合声学CAD评分进行排除,减少不必要的有创检查。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Validation studies of the 2019 European Society of Cardiology pretest probability model (ESC-PTP) for coronary artery disease (CAD) report that 35%-40% of patients have low pretest probability (ESC-PTP 5% to <15%). Acoustic detection of coronary stenoses could potentially improve clinical likelihood stratification. Aims were to (1) investigate the diagnostic performance of an acoustic-based CAD score and (2) study the reclassification potential of a dual likelihood strategy by the ESC-PTP and a CAD score. METHODS: Consecutive patients (n=1683) with stable angina symptoms referred for coronary CT angiography (CTA) underwent heart sound analyses by an acoustic CAD-score device. All patients with ≥50% luminal stenosis in any coronary segment at coronary CTA were referred to investigation with invasive coronary angiography (ICA) with fractional flow reserve (FFR).A predefined CAD-score cut-off ≤20 was used to rule out obstructive CAD. RESULTS: In total, 439 patients (26%) had ≥50% luminal stenosis on coronary CTA. The subsequent ICA with FFR showed obstructive CAD in 199 patients (11.8%). Using the ≤20 CAD-score cut-off for obstructive CAD rule-out, sensitivity was 85.4% (95% CI 79.7 to 90.0), specificity 40.4% (95% CI 37.9 to 42.9), positive predictive value 16.1% (95% CI 13.9 to 18.5) and negative predictive value 95.4% (95% CI 93.4 to 96.9) in all patients. Applying the cut-off in ESC-PTP 5% to <15% patients, 316 patients (48%) were down-classified to very-low likelihood. The obstructive CAD prevalence was 3.5% in this group. CONCLUSION: In a large contemporary cohort of patients with low CAD likelihood, the additional use of an acoustic rule-out device showed a clear potential to downgrade likelihood and could supplement current strategies for likelihood assessment to avoid unnecessary testing. TRIAL REGISTRATION NUMBER: NCT03481712.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Rasmussen LD, Winther S, Karim SR, et al. Likelihood reclassification by an acoustic-based score in suspected coronary artery disease. Heart. 2023. PMID: 36878672. doi:10.1136/heartjnl-2023-322357

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。