高功率短时程上腔静脉隔离联合常规射频消融治疗阵发性房颤的随机对照试验

[Safety and efficacy of high-power, short-duration superior vena cava isolation in combination with conventional radiofrequency ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial].
PubMed 文献 · Zhonghua Xin Xue Guan Bing Za Zhi · 2022-01-01

本研究为前瞻性随机对照试验,纳入60例伴上腔静脉触发电位且肌袖长度≥3 cm的阵发性房颤患者,随机分为高功率短时程(HPSD)组和常规功率(CPD)组各30例。结果显示HPSD组上腔静脉隔离的消融点数、隔离时间和消融时间均显著少于CPD组,阻抗下降更明显,两组安全性事件无显著差异。

要点

  • HPSD组上腔静脉隔离的消融点数为14(13,15)个,少于CPD组的20(18,22)个(P<0.001)。
  • HPSD组隔离时间为8(7,9)min,短于CPD组的17(14,20)min(P<0.001)。
  • 两组均未发生心脏压塞、膈神经损伤、窦房结损伤和死亡,POP发生率差异无统计学意义。

核心结论

  • 对于行常规射频消融的阵发性房颤患者,采用高功率短时程技术进行上腔静脉隔离安全、有效。

研究设计与样本

  • 前瞻性随机对照试验,连续筛查180例因阵发性房颤行射频消融术的患者,最终纳入60例上腔静脉内伴触发电位且肌袖长度≥3 cm者,随机分为HPSD组和CPD组各30例。

主要发现

  • HPSD组消融14(13,15)个点后达到上腔静脉隔离,少于CPD组的20(18,22)个点(P<0.001)。
  • HPSD组上腔静脉隔离时间为8(7,9)min,短于CPD组的17(14,20)min(P<0.001)。
  • HPSD组消融放电时间为78.0(71.1,80.0)s,短于CPD组的200.0(167.5,212.5)s(P<0.001)。
  • HPSD组阻抗下降20.00(18.75,21.00)Ω(下降百分比15%),较CPD组的12.00(11.75,13.25)Ω(下降百分比12%)更明显(P<0.001)。
  • HPSD组1例(3.3%)发生POP,CPD组3例(10.0%),两组差异无统计学意义(P>0.05);两组均无心脏压塞、膈神经损伤、窦房结损伤和死亡。

关键数值与推荐

  • 纳入标准:上腔静脉内伴有触发电位且肌袖长度≥3 cm的阵发性房颤患者。
  • 有效性指标包括消融点数、隔离时间、消融时间;安全性指标包括POP、心脏压塞、膈神经损伤、窦房结损伤、全因死亡。

临床怎么用

  • 在阵发性房颤患者行常规射频消融时,可考虑采用高功率短时程技术进行上腔静脉隔离,以减少消融点数、缩短隔离时间和消融时间。
  • HPSD上腔静脉隔离未增加心脏压塞、膈神经损伤、窦房结损伤等安全性事件,但需注意POP的发生。

局限性

  • 研究仅纳入符合特定条件(上腔静脉触发电位且肌袖长度≥3 cm)的60例患者,样本量较小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: For patients with paroxysmal atrial fibrillation, superior vena cava isolation on the basis of pulmonary vein isolation may further improve the long-term success rate of radiofrequency ablation. We aimed to explore the efficacy and safety of superior vena cava isolation by high-power and short-duration (HPSD) ablation plus conventional radiofrequency ablation (RA) in patients with paroxysmal atrial fibrillation. Methods: It was a prospective randomized controlled study. From January 1, 2019 to June 1, 2020, 180 patients who underwent radiofrequency ablation for paroxysmal atrial fibrillation in our center were consecutively screened. Patients were eligible if there was a trigger potential and the muscle sleeve length was greater than 3 cm. A total of 60 eligible patients were finally included and randomly divided into HPSD group (HPSD plus RA) and common power and duration (CPD) group (CPD plus RA) by random number table method (n=30 in each group). Efficacy was evaluated by ablation points, isolation time and ablation time. Safety was evaluated by the incidence of POP, cardiac tamponade, phrenic nerve injury, sinoatrial node injury and all-cause. Results: Superior vena cava isolation was achieved by 14 (13, 15) points in the HPSD group, which was significantly less than that in the CPD group (20(18, 22), P<0.001). The superior vena cava isolation time was 8 (7, 9) minutes in the HPSD group, which was significantly shorter than in the CPD group (17(14, 20) minutes, P<0.001). The average ablation time significantly shorter in HPSD group than in CPD group (78.0(71.1, 80.0) s vs. 200(167.5, 212.5)s, P<0.001). The average impedance drop was more significant in the HPSD group than in the CPD group (20.00(18.75, 21.00)Ω (and the percentage of impedance drop was 15%) vs. 12.00(11.75, 13.25)Ω (the percentage of impedance decrease was 12%), P<0.001). There was 1 POP (3.3%) in the HPSD group, and 3 POPs (10.0%) in the CPD group (P>0.05). There was no cardiac tamponade, phrenic nerve injury, sinoatrial node injury and death in both groups. Conclusions: HPSD technique for the isolation of superior vena cava is safe and effective in patients with paroxysmal atrial fibrillation undergoing conventional radiofrequency ablation. 目的: 探讨在肺静脉隔离的基础上,对于阵发性心房颤动(房颤)患者采用高功率短时程的消融方法进行上腔静脉隔离的安全性和有效性。 方法: 该研究为随机对照试验。连续纳入2019年1月1日至2020年6月1日因阵发性房颤行射频消融术的患者180例,对其中上腔静脉内伴有触发电位且肌袖长度≥3 cm者行上腔静脉隔离,最终纳入符合条件者60例,采用随机数表法将入选患者分入高功率组和常规功率组,每组30例。有效性观察指标包括消融点数、隔离时间、消融时间,安全性观察指标包括消融过程中发生的爆裂声(POP)、心脏压塞、膈神经损伤、窦房结损伤、全因死亡。 结果: 高功率组消融14(13,15)个点后达到了上腔静脉隔离,少于常规功率组的20(18,22)个点(P<0.001)。高功率组上腔静脉隔离时间为8(7,9)min,短于常规功率组的17(14,20)min(P<0.001)。高功率组消融放电时间为78.0(71.1,80.0)s,短于常规功率组的200.0(167.5,212.5)s(P<0.001)。高功率组阻抗下降20.00(18.75,21.00)Ω(阻抗下降百分比为15%),较常规功率组的12.00(11.75,13.25)Ω(阻抗下降百分比为12%)下降更为明显(P<0.001)。高功率组1例(3.3%)患者发生POP,常规功率组3例(10.0%),两组间差异无统计学意义(P>0.05)。两组患者均未发生心脏压塞、膈神经损伤、窦房结损伤和死亡。 结论: 采用高功率短时程的消融方法对于阵发性房颤患者进行上腔静脉隔离安全、有效。.

来源:Zhonghua Xin Xue Guan Bing Za Zhi,查看原文。版权归原作者所有。

引用

  1. Duan JB, He JS, Wu CC, et al. [Safety and efficacy of high-power, short-duration superior vena cava isolation in combination with conventional radiofrequency ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial]. Zhonghua Xin Xue Guan Bing Za Zhi. 2022. PMID: 36418274. doi:10.3760/cma.j.cn112148-20220501-00338