脉冲场消融治疗房颤时诱发冠状动脉痉挛
本研究在脉冲场消融(PFA)常规房颤消融过程中行冠状动脉造影,发现远离冠状动脉的消融(肺静脉隔离、左房后壁)未诱发痉挛,而邻近右冠状动脉的峡部消融在连续5例中均诱发严重亚全痉挛,预防性给予硝酸甘油可避免。
要点
- 远离冠状动脉的PFA消融未诱发冠状动脉痉挛。
- 邻近右冠状动脉的峡部消融常规诱发亚临床严重痉挛。
- 预防性硝酸甘油可避免PFA诱发的冠状动脉痉挛。
核心结论
- PFA在远离冠状动脉部位不诱发痉挛,邻近冠状动脉时常规诱发亚临床痉挛,硝酸甘油可缓解或预防。
研究设计与样本
- 在常规房颤PFA消融中行冠状动脉造影的前后对照观察性研究;肺静脉隔离25例、左房后壁消融5例、峡部消融20例。
主要发现
- 肺静脉隔离和左房后壁消融期间未发生冠状动脉痉挛。
- 峡部消融在连续5例中均诱发严重亚全痉挛,经冠状动脉内硝酸甘油在5.5±3.5分钟内缓解。
- 未观察到ST段抬高。
- 预先给予硝酸甘油(冠状动脉内5例或静脉10例)后无患者发生严重痉挛(0%,P=0.004)。
关键数值与推荐
- 峡部消融诱发严重亚全痉挛5/5(100%)。
- 预先给予硝酸甘油后严重痉挛发生率为0%(P=0.004)。
- 痉挛经冠状动脉内硝酸甘油在5.5±3.5分钟内缓解。
临床怎么用
- 在邻近冠状动脉部位行PFA消融时应考虑预防性使用硝酸甘油以降低痉挛风险。
- 术中出现痉挛时可冠状动脉内给予硝酸甘油缓解。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Pulsed field ablation (PFA) has a unique safety profile when used to treat atrial fibrillation, largely related to its preferentiality for myocardial tissue ablation, in particular, esophageal sparing. A pentaspline catheter was the first such PFA system studied clinically for atrial fibrillation ablation; in these initial regulatory trials, the catheter was used for pulmonary vein isolation and left atrial posterior wall ablation. Since its regulatory approval in Europe, in clinical practice, physicians have ablated beyond pulmonary vein isolation and left atrial posterior wall ablation to expanded lesion sets in closer proximity to coronary arteries. This is an unstudied important issue because preclinical and clinical data have raised the potential for coronary arterial spasm. Herein, we studied the vasospastic potential of PFA lesion sets, both remote from and adjacent to coronary arteries. METHODS: During routine atrial fibrillation ablation using the pentaspline PFA catheter, coronary angiography was performed before, during, and after pulsed field applications. The lesion sets studied included: (1) those remote from the coronary arteries such as pulmonary vein isolation (n=25 patients) and left atrial posterior wall ablation (n=5), and (2) ablation of the cavotricuspid isthmus (n=20) that is situated adjacent to the right coronary artery. RESULTS: During pulmonary vein isolation and left atrial posterior wall ablation, coronary spasm did not occur, but cavotricuspid isthmus ablation provoked severe subtotal vasospasm in 5 of 5 (100%) consecutive patients, and this was relieved by intracoronary nitroglycerin in 5.5±3.5 minutes. ST-segment elevation was not observed. However, no patient (0%, P=0.004) had severe spasm if first administered parenteral nitroglycerin, either intracoronary (n=5) or intravenous (n=10), before treatment. CONCLUSIONS: Coronary vasospasm was not provoked during PFA at locations remote from coronary arteries, but when the energy is delivered adjacent to a coronary artery, PFA routinely provokes subclinical vasospasm. This phenomenon is attenuated by nitroglycerin, administered either post hoc to treat spasm or as prophylaxis.
引用
- Reddy VY, Petru J, Funasako M, et al. Coronary Arterial Spasm During Pulsed Field Ablation to Treat Atrial Fibrillation. Circulation. 2022. PMID: 36134574. doi:10.1161/CIRCULATIONAHA.122.061497
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。