文献速递冠心病

CZT SPECT心肌定量血流对冠心病诊断效能及增益价值

[Diagnostic efficiency and incremental value of myocardial blood flow quantification by CZT SPECT for patients with coronary artery disease].
PubMed 文献 · Zhonghua Xin Xue Guan Bing Za Zhi · 2022-01-01

本研究为回顾性横断面研究,纳入98例可疑或确诊冠心病患者,比较CZT SPECT动态MPI定量心肌血流参数与传统半定量参数对冠心病的诊断效能。结果显示,以冠状动脉狭窄≥50%或≥75%为阳性标准时,定量血流参数的灵敏度、特异度、预测值及准确度均高于半定量参数,具有增量诊断价值。

要点

  • CZT SPECT定量心肌血流参数诊断冠心病效能优于传统半定量参数。
  • 以狭窄≥50%为标准,定量参数灵敏度86.1%、特异度82.6%、准确度84.0%。
  • 以狭窄≥75%为标准,定量参数灵敏度89.2%、阴性预测值95.5%。

核心结论

  • 与传统SPECT MPI半定量参数相比,CZT SPECT心肌定量血流参数对冠心病诊断效能较高,具有较佳的诊断增益价值。

研究设计与样本

  • 回顾性、横断面研究,纳入2018年10月至2020年12月于泰达国际心血管病医院完成CZT SPECT动态MPI定量血流测定的可疑或确诊冠心病患者98例,年龄(62.1±8.7)岁,男性66例(67%)。

主要发现

  • 患者水平以冠状动脉狭窄≥50%为阳性标准时,狭窄组(58例)LV-sMBF(1.36±0.45)ml·min-1·g-1和LV-MFR(1.45±0.43)低于对照组(40例)的(2.09±0.64)ml·min-1·g-1和(2.17±0.54),负荷总积分和差值总积分高于对照组(P均<0.05)。
  • 患者水平以狭窄≥75%为阳性标准时,狭窄组(38例)LV-sMBF(1.19±0.34)ml·min-1·g-1和LV-MFR(1.34±0.35)低于对照组(60例)的(1.94±0.63)ml·min-1·g-1和(2.00±0.58),各半定量参数均高于对照组(P均<0.05)。
  • 血管水平以狭窄≥50%为阳性标准时,狭窄组(122支)sMBF(1.26±0.49)ml·min-1·g-1和MFR(1.35±0.46)低于对照组的(1.95±0.70)ml·min-1·g-1和(2.05±0.65),负荷积分和差值积分高于对照组(P均<0.05)。
  • 血管水平以狭窄≥75%为阳性标准时,狭窄组(74支)sMBF(1.12±0.41)ml·min-1·g-1和MFR(1.25±0.38)低于对照组(220支)的(1.84±0.70)ml·min-1·g-1和(1.93±0.66),各半定量参数均高于对照组(P均<0.05)。

关键数值与推荐

  • 以冠状动脉狭窄≥50%为阳性标准、CAG为参考,定量血流参数诊断冠心病的AUC(95%CI)为0.830(0.783~0.877),灵敏度86.1%比61.5%、特异度82.6%比73.8%、阳性预测值77.8%比62.5%、阴性预测值89.3%比73.0%、准确度84.0%比68.7%,均高于半定量参数(P均<0.05)。
  • 以冠状动脉狭窄≥75%为阳性标准,定量血流参数诊断冠心病的AUC(95%CI)为0.832(0.785~0.879),灵敏度89.2%比67.6%、阴性预测值95.5%比86.2%、准确度80.6%比68.0%,均高于半定量参数(P均<0.05)。

临床怎么用

  • 在可疑或确诊冠心病患者中,采用CZT SPECT动态MPI定量心肌血流参数(sMBF、MFR)可提高诊断效能,具有增量价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the diagnostic efficiency and incremental value of quantitative myocardial blood flow measurements by Cadmium-Zine-Telluride (CZT) single photon emission computed tomography (SPECT) dynamic myocardial perfusion imaging (MPI) in patients with coronary artery disease (CAD) compared with traditional semi-quantitative measurements by MPI. Methods: This is a retrospective, cross-sectional study. We retrospectively analyzed clinical data of patients with suspected or known CAD, who underwent the dynamic MPI quantitative blood flow measurement of CZT SPECT in TEDA International Cardiovascular Hospital from October 2018 to December 2020. Clinical data, semi-quantitative parameters (stress score (SS), rest score (RS) and different score (DS)) and myocardial quantitative blood flow parameters (rest myocardial blood flow (rMBF), stress myocardial blood flow (sMBF) and myocardial flow reserve (MFR)) were analyzed. According to the results of coronary angiography, patients were divided into the stenosis group and the control group with coronary artery stenosis ≥50% or ≥75% as the diagnosis criteria. The differences of quantitative and semi-quantitative parameters between the two groups were compared, and the diagnostic efficacy was compared by receiver operating characteristic(ROC) curve. Results: A total of 98 patients with a mean age of (62.1±8.7) years were included in the study, including 66 males (67%). At the patient level, with the positive standard of coronary artery stenosis≥50%, the left ventricle (LV) stress MBF (LV-sMBF) ((1.36±0.45) ml·min-1·g-1) and LV-MFR (1.45±0.43) of the stenosis group were lower than the LV-sMBF ((2.09±0.64) ml·min-1·g-1) and LV-MFR (2.17±0.54) of control group; summed SS and summed DS were higher than control group (all P<0.05). With the positive standard of coronary artery stenosis ≥75%, the LV-sMBF ((1.19±0.34) ml·min-1·g-1) and LV-MFR (1.34±0.35) of stenosis group were lower than the LV-sMBF ((1.94±0.63) ml·min-1·g-1) and MFR (2.00±0.58) of control group; all semi-quantitative parameters were higher than control group (all P<0.05). At the vascular level, with coronary artery stenosis ≥50% as the diagnosis criteria, the sMBF ((1.26±0.49) ml·min-1·g-1) and MFR (1.35±0.46) of stenosis group were lower than the sMBF ((1.95±0.70) ml·min-1·g-1) and MFR (2.05±0.65) of control group; SS and DS were higher than control group (all P<0.05). With coronary artery stenosis≥75% as the diagnosis criteria, the sMBF ((1.12±0.41) ml·min-1·g-1) and MFR (1.25±0.38) of stenosis group were lower than the sMBF ((1.84±0.70) ml·min-1·g-1) and MFR (1.93±0.66) of control group; all semi-quantitative parameters were higher than control group (all P<0.05). With coronary artery stenosis≥50% as the diagnosis criteria and CAG as the reference standard, the AUC and 95%CI of myocardial quantitative blood flow parameters indicated by ROC curve for diagnosis of CAD were 0.830 (0.783-0.877). The sensitivity (86.1% vs. 61.5%), specificity (82.6% vs. 73.8%), positive predictive value (77.8% vs. 62.5%), negative predictive value (89.3% vs. 73.0%) and accuracy (84.0% vs. 68.7%) were all higher than the semi-quantitative parameters (all P<0.05). With coronary artery stenosis≥75% as the diagnosis criteria, the AUC and 95%CI of myocardial quantitative blood flow parameters indicated by ROC curve for diagnosis of CAD were 0.832(0.785-0.879). The sensitivity (89.2% vs. 67.6%), negative predictive value (95.5% vs. 86.2%) and accuracy (80.6% vs. 68.0%) were all higher than semi-quantitative parameters (all P<0.05). Conclusion: Compared with traditional SPECT MPI derived semi-quantitative parameters, diagnostic efficacy for CAD is higher using CZT SPECT quantitative myocardial blood flow parameters, this strategy thus has additional diagnostic benefits and incremental value on the diagnosis of CAD. 目的: 探讨与传统心肌灌注显像(MPI)半定量参数相比,碲锌镉(CZT)单光子发射计算机断层成像(SPECT)动态MPI测定的心肌定量血流参数对冠心病的诊断效能及其增益价值。 方法: 本研究为回顾性、横断面研究。选取2018年10月至2020年12月期间于泰达国际心血管病医院成功完成CZT SPECT动态MPI定量血流测定的可疑或确诊冠心病患者。收集患者的基本临床资料,CZT SPECT测定MPI半定量参数(负荷积分、静息积分和差值积分)及心肌定量血流参数[静息心肌血流量(rMBF)、负荷心肌血流量(sMBF)和心肌血流储备(MFR)]。根据冠状动脉血管造影结果,分别以任意一支冠状动脉狭窄≥50%或≥75%两种情况作为判断狭窄的阳性参考标准,将患者分为狭窄组和对照组。比较两组间心肌定量血流参数及半定量参数的差异,并采用受试者工作特征(ROC)曲线比较两种类型参数对冠心病的诊断效能。 结果: 共纳入98例患者,年龄(62.1±8.7)岁,其中男性66例(67%)。在患者水平,以冠状动脉狭窄程度≥50%为阳性标准时,狭窄组(58例)左心室sMBF(LV-sMBF)[(1.36±0.45)ml·min-1·g-1比(2.09±0.64)ml·min-1·g-1]和左心室MFR(LV-MFR)[(1.45±0.43)比(2.17±0.54)]均低于对照组(40例);狭窄组负荷总积分和差值总积分均高于对照组(P均<0.05)。以冠状动脉狭窄程度≥75%为阳性标准时,狭窄组(38例)LV-sMBF[(1.19±0.34)ml·min-1·g-1比(1.94±0.63)ml·min-1·g-1]和LV-MFR[(1.34±0.35)比(2.00±0.58)]均低于对照组(60例);狭窄组各半定量参数均高于对照组(P均<0.05)。在血管水平,以冠状动脉狭窄程度≥ 50%为阳性标准时,狭窄组(122支)sMBF[(1.26±0.49)ml·min-1·g-1比(1.95±0.70)ml·min-1·g-1]和MFR[(1.35±0.46)比(2.05±0.65)]均低于对照组;狭窄组负荷积分和差值积分均高于对照组(P均<0.05)。以冠状动脉狭窄程度≥75%为阳性标准时,狭窄组(74支)sMBF[(1.12±0.41)ml·min-1·g-1比(1.84±0.70)ml·min-1·g-1]和MFR[(1.25±0.38)比(1.93±0.66)]均低于对照组(220支);狭窄组各半定量参数均高于对照组(P均<0.05)。以冠状动脉狭窄程度≥50%为阳性标准时,ROC曲线示心肌定量血流参数诊断冠心病的AUC和95%CI为0.830(0.783~0.877),其灵敏度(86.1%比61.5%)、特异度(82.6%比73.8%)、阳性预测值(77.8%比62.5%)、阴性预测值(89.3%比73.0%)和准确度(84.0%比68.7%)均高于半定量参数(P均<0.05);以冠状动脉狭窄程度≥75%为阳性标准时,心肌定量血流参数诊断冠心病的AUC和95%CI为0.832(0.785~0.879),其灵敏度(89.2%比67.6%)、阴性预测值(95.5%比86.2%)和准确度(80.6%比68.0%)也均高于半定量参数(P均<0.05)。 结论: 与传统SPECT MPI半定量参数相比,CZT SPECT心肌定量血流参数对冠心病的诊断效能较高,具有较佳的诊断增益价值。.

来源:Zhonghua Xin Xue Guan Bing Za Zhi,查看原文。版权归原作者所有。

引用

  1. Pang ZK, Wang J, Chen Y, et al. [Diagnostic efficiency and incremental value of myocardial blood flow quantification by CZT SPECT for patients with coronary artery disease]. Zhonghua Xin Xue Guan Bing Za Zhi. 2022. PMID: 35589599. doi:10.3760/cma.j.cn112148-20211124-01018