文献速递心律失常

长QT综合征中的机电交互与心律失常发生

Electromechanical reciprocity and arrhythmogenesis in long-QT syndrome and beyond.
PubMed 文献 · Eur Heart J · 2022-01-01

本文综述长QT综合征(LQTS)中机电交互(电-机械反馈)对心律失常的作用。LQTS存在机电离散,病理性复极延长超过机械收缩期,产生负性机电窗(EMW),在症状患者中最显著。EMW是优于心率校正QT的独立心律失常风险预测指标,负性EMW提示复极仍在进行时心室被充盈变形,形成致敏基质,可被电或机械刺激触发异常冲动。

要点

  • LQTS不仅为电性疾病,机电交互参与心律失常发生。
  • 负性机电窗(EMW)是独立且优于QTc的风险预测指标。
  • 交感激活和 pause 依赖增强可加重机电异质性。

核心结论

  • 机电交互(电-机械反馈)在LQTS及其他心脏疾病的心律失常发生中起重要作用。
  • 负性机电窗提示致敏的机电基质,可被局部后除极、后收缩或不同步触发异常冲动。

研究设计与样本

  • 综述,聚焦LQTS中机电交互与心律失常发生,并讨论实时图像整合电生理与力学的应用前景。

主要发现

  • LQTS机电离散表现为异质性延长的室性复极,同时收缩时长和松弛改变。
  • 机械改变可能偏离整体和区域复极异常所预期。
  • LQTS患者病理性复极延长超过机械收缩期,产生负性机电窗,症状患者最显著。
  • 机电窗是优于心率校正QT的独立心律失常风险预测指标。
  • 负性机电窗时,快速充盈期复极仍在进行,心室因容量负荷而变形,形成致敏基质。

关键数值与推荐

  • 机电窗是优于心率校正QT的独立心律失常风险预测指标。
  • 负性机电窗意味着复极仍在进行时心室在快速充盈期因容量负荷而变形。

临床怎么用

  • 临床可关注LQTS患者的机电窗以评估心律失常风险。
  • 实时图像整合心脏电生理与力学为心律失常管理提供新机会。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

An abundance of literature describes physiological and pathological determinants of cardiac performance, building on the principles of excitation-contraction coupling. However, the mutual influencing of excitation-contraction and mechano-electrical feedback in the beating heart, here designated 'electromechanical reciprocity', remains poorly recognized clinically, despite the awareness that external and cardiac-internal mechanical stimuli can trigger electrical responses and arrhythmia. This review focuses on electromechanical reciprocity in the long-QT syndrome (LQTS), historically considered a purely electrical disease, but now appreciated as paradigmatic for the understanding of mechano-electrical contributions to arrhythmogenesis in this and other cardiac conditions. Electromechanical dispersion in LQTS is characterized by heterogeneously prolonged ventricular repolarization, besides altered contraction duration and relaxation. Mechanical alterations may deviate from what would be expected from global and regional repolarization abnormalities. Pathological repolarization prolongation outlasts mechanical systole in patients with LQTS, yielding a negative electromechanical window (EMW), which is most pronounced in symptomatic patients. The electromechanical window is a superior and independent arrhythmia-risk predictor compared with the heart rate-corrected QT. A negative EMW implies that the ventricle is deformed-by volume loading during the rapid filling phase-when repolarization is still ongoing. This creates a 'sensitized' electromechanical substrate, in which inadvertent electrical or mechanical stimuli such as local after-depolarizations, after-contractions, or dyssynchrony can trigger abnormal impulses. Increased sympathetic-nerve activity and pause-dependent potentiation further exaggerate electromechanical heterogeneities, promoting arrhythmogenesis. Unraveling electromechanical reciprocity advances the understanding of arrhythmia formation in various conditions. Real-time image integration of cardiac electrophysiology and mechanics offers new opportunities to address challenges in arrhythmia management.

来源:Eur Heart J,查看原文。版权归原作者所有。

引用

  1. Odening KE, van der Linde HJ, Ackerman MJ, et al. Electromechanical reciprocity and arrhythmogenesis in long-QT syndrome and beyond. Eur Heart J. 2022. PMID: 35445703. doi:10.1093/eurheartj/ehac135

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。