文献速递心律失常

智能手机光电容积脉搏波检测房颤的系统综述与荟萃分析

Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis.
PubMed 文献 · Heart · 2022-09-26

17项研究20组比较的荟萃分析显示,合并敏感度94%(95%CI 92%-95%)、特异度97%(96%-98%),但研究整体质量差、存在选择偏倚和发表偏倚,证据尚有限。

要点

  • 智能手机PPG检测房颤的合并敏感度94%、特异度97%,但异质性显著(p<0.01)。
  • 纳入研究多为小样本、二级医疗场景,且无一项完全满足QUADAS-2标准。
  • PPG可作为无创、患者主导的房颤筛查工具,但当前证据质量低,需独立研究验证。

核心结论

  • 智能手机PPG可为房颤提供无创、患者主导的筛查手段,但现有证据限于小样本、有偏倚的低质量研究,敏感度和特异度可能被高估。
  • 需开展 preferably 独立于制造商的进一步研究,以明确PPG检测房颤的真实价值。

研究设计与样本

  • 系统综述检索MEDLINE、EMBASE和Cochrane(1980年至2020年12月),纳入任何比较智能手机PPG与参考心电图(1、3或12导联)的研究或摘要。
  • 采用随机效应荟萃分析合并敏感度和特异度,并评估发表偏倚,使用QUADAS-2工具评价研究质量。

主要发现

  • 各研究敏感度范围为81%至100%,特异度范围为85%至100%。
  • 17项研究的20组比较(6891名参与者,其中2299例房颤)纳入荟萃分析,合并敏感度94%(95%CI 92%-95%),合并特异度97%(96%-98%),异质性显著(p<0.01)。
  • 研究整体质量差,无一项完全满足QUADAS-2标准,尤其存在选择偏倚和潜在发表偏倚问题。
  • 多数研究样本量小且基于二级医疗场景。

临床怎么用

  • PPG可作为房颤的无创、患者主导筛查工具,但临床解读其结果时应考虑现有证据质量低、敏感度和特异度可能被高估的局限。
  • 在获得更高质量独立研究证据前,不宜仅凭PPG结果替代常规心电图诊断房颤。

局限性

  • 纳入研究整体质量差,无一项完全满足QUADAS-2标准,尤其存在选择偏倚。
  • 存在潜在发表偏倚。
  • 多数研究样本量小且基于二级医疗场景,敏感度和特异度可能不切实际地偏高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Timely diagnosis of atrial fibrillation (AF) is essential to reduce complications from this increasingly common condition. We sought to assess the diagnostic accuracy of smartphone camera photoplethysmography (PPG) compared with conventional electrocardiogram (ECG) for AF detection. METHODS: This is a systematic review of MEDLINE, EMBASE and Cochrane (1980-December 2020), including any study or abstract, where smartphone PPG was compared with a reference ECG (1, 3 or 12-lead). Random effects meta-analysis was performed to pool sensitivity/specificity and identify publication bias, with study quality assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) risk of bias tool. RESULTS: 28 studies were included (10 full-text publications and 18 abstracts), providing 31 comparisons of smartphone PPG versus ECG for AF detection. 11 404 participants were included (2950 in AF), with most studies being small and based in secondary care. Sensitivity and specificity for AF detection were high, ranging from 81% to 100%, and from 85% to 100%, respectively. 20 comparisons from 17 studies were meta-analysed, including 6891 participants (2299 with AF); the pooled sensitivity was 94% (95% CI 92% to 95%) and specificity 97% (96%-98%), with substantial heterogeneity (p<0.01). Studies were of poor quality overall and none met all the QUADAS-2 criteria, with particular issues regarding selection bias and the potential for publication bias. CONCLUSION: PPG provides a non-invasive, patient-led screening tool for AF. However, current evidence is limited to small, biased, low-quality studies with unrealistically high sensitivity and specificity. Further studies are needed, preferably independent from manufacturers, in order to advise clinicians on the true value of PPG technology for AF detection.

来源:Heart,查看原文。版权归原作者所有。

引用

  1. Gill S, Bunting KV, Sartini C, et al. Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis. Heart. 2022. PMID: 35277454. doi:10.1136/heartjnl-2021-320417

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。