18F-FDG PET/CT测量的左心房心外膜脂肪炎症活性与心房颤动的相关性
本研究回顾性纳入78例房颤患者并按1∶1倾向性评分匹配78例非房颤对照,采用18F-FDG PET/CT测量左心房心外膜脂肪炎症活性(LA-EAT FDG SUVmax)及总EAT体积。结果显示LA-EAT FDG SUVmax是房颤的独立相关因素,其增高与房颤正相关,最佳诊断界值为1.415。
要点
- LA-EAT FDG SUVmax是房颤的独立相关因素(OR=1.375)。
- LA-EAT FDG SUVmax≥1.415与房颤独立相关(OR=2.982)。
- LA-EAT FDG SUVmax诊断房颤的AUC为0.680,灵敏度65.4%,特异度61.5%。
核心结论
- 18F-FDG PET/CT测量的LA-EAT炎症活性是房颤的影响因素,LA-EAT炎症活性增高与房颤正相关。
研究设计与样本
- 回顾性研究,纳入2018年3月至2019年12月于苏州大学附属第三医院行18F-FDG PET/CT的78例房颤患者,按1∶1倾向性评分匹配78例非房颤对照。
主要发现
- 房颤组LAD为(44.2±5.8)mm、V-EAT为(122.1±42.0)cm3、LA-EAT FDG SUVmax为(1.6±0.3),均高于对照组(P均<0.001)。
- 房颤组LVEF为(60.1±4.7)%,低于对照组(63.9±2.9)%(P<0.001)。
- 多因素logistic回归显示LAD(OR=1.340,95%CI 1.195~1.502)、V-EAT(OR=1.016,95%CI 1.001~1.031)、LA-EAT FDG SUVmax(OR=1.375,95%CI 1.095~1.723)与房颤正相关。
- LVEF(OR=0.781,95%CI 0.659~0.926)与房颤负相关(P均<0.05)。
- 校正HDL-C、LVEF、LAD、V-EAT后,LA-EAT FDG SUVmax≥1.415与房颤独立相关(OR=2.982,95%CI 1.122~7.926,P=0.010)。
关键数值与推荐
- LA-EAT FDG SUVmax诊断房颤的ROC曲线下面积为0.680(95%CI 0.597~0.764,P<0.001)。
- LA-EAT FDG SUVmax判断房颤的最佳界值为1.415,灵敏度65.4%,特异度61.5%。
临床怎么用
- 对于因肿瘤指标异常或恶性肿瘤行18F-FDG PET/CT的患者,可关注LA-EAT FDG SUVmax以评估房颤风险。
- LA-EAT FDG SUVmax≥1.415提示房颤风险增高,可作为房颤风险分层的参考指标之一。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To explore the association between inflammation activity of left atrial epicardial adipose tissue (LA-EAT) measured by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and atrial fibrillation (AF). Methods: A total of 78 patients with AF, who underwent 18F-FDG PET/CT in the Nuclear Medicine Department of the Third Affiliated Hospital of Soochow University due to abnormally elevated levels of tumor indicators or malignant tumors from March 2018 to December 2019, were enrolled in this retrospective study. According to the examination date of PET/CT and basic characteristics of AF patients (gender, age), a 1∶1 propensity score matching was used to enroll a non-AF control group (78 patients). The maximum standard uptake value of left atrial epicardial tissue (LA-EAT FDG SUVmax) and total EAT volume (V-EAT) were measured by 18F-FDG PET/CT. Left ventricular ejection fraction (LVEF) and left atrial diameter (LAD) were obtained by echocardiography. Blood lipids and biomarkers of inflammation were measured. The differences of clinical data and EAT-related indicators were compared between the AF group and control group. Logistic multivariate regression analysis was used to determine the related factors of AF. Then the receiver operating characteristic (ROC) curve was used to determine the cutoff value of LA-EAT FDG SUVmax on the diagnosis of AF. Univariate and multivariate logistic regression analysis were used to analyze the relationship between the increase of LA-EAT FDG SUVmax and AF. Results: The age was (66.9±10.2) years and there were 55 males (70.5%) in the AF group. The age was (66.9±8.0) years, and there were 52 males (66.7%) in the control group (both P>0.05). The LAD ((44.2±5.8) mm vs. (35.4±4.4) mm), V-EAT ((122.1±42.0) cm3 vs. (91.6±34.5) cm3), and LA-EAT FDG SUVmax ((1.6±0.3) vs. (1.4±0.2)) values were significantly higher, while LVEF ((60.1±4.7)% vs. (63.9±2.9)%) was lower in the AF group than in the control group (P all<0.001). Multivariate logistic regression analysis showed that LAD (OR=1.340, 95%CI 1.195-1.502), V-EAT (OR=1.016, 95%CI 1.001-1.031), and LA-EAT FDG SUVmax (OR=1.375, 95%CI 1.095-1.723) were positively correlated with AF, LVEF (OR=0.781, 95%CI 0.659-0.926) was negatively correlated with AF(P all<0.05). The area under the ROC curve of LA-EAT FDG SUVmax for diagnosis of AF was 0.680 (95%CI 0.597-0.764, P<0.001), and the best cut-off value was 1.415 with a sensitivity of 65.4% and specificity of 61.5%. After adjusting for high-density lipoprotein cholesterol, LVEF, LAD and V-EAT, LA-EAT FDG SUVmax≥1.415 was independently associated with AF (OR=2.982, 95%CI 1.122-7.926, P=0.010). Conclusions: The inflammatory activity of LA-EAT measured by 18F-FDG PET/CT is an independent risk factor of AF, and the increased inflammatory activity of LA-EAT is positively correlated with AF. 目的: 探讨氟-18-脱氧葡萄糖(18F-FDG)正电子发射型计算机断层扫描(PET/CT)测量的左心房心外膜脂肪(LA-EAT)炎症活性与心房颤动(房颤)的相关性。 方法: 回顾性分析2018年3月至2019年12月因肿瘤指标异常升高或恶性肿瘤于苏州大学附属第三医院核医学科行18F-FDG PET/CT检查的78例房颤患者。按照PET/CT检查日期、年龄、性别等基本特征进行1∶1倾向性评分匹配,设立非房颤对照组(78例)。采用18F-FDG PET/CT测量左心房心外膜脂肪最大标准摄取值(LA-EAT FDG SUVmax)和总EAT体积(V-EAT),超声心动图获得左心室射血分数(LVEF)和左心房内径(LAD),并收集血脂和血炎症指标。比较房颤组和对照组患者临床资料及相关EAT指标的差异;采用多因素logistic回归分析房颤的相关因素;采用受试者工作特征(ROC)曲线及曲线下面积评估LA-EAT FDG SUVmax判断房颤的价值;采用ROC曲线寻找LA-EAT FDG SUVmax判断房颤的最佳界值并据其定义LA-EAT FDG SUVmax增高,单因素和多因素logistic回归分析LA-EAT FDG SUVmax增高与房颤的关系。 结果: 房颤组年龄(66.9±10.2)岁,男性55例(70.5%),对照组年龄(66.9±8.0)岁,男性52例(66.7%),两组的年龄、性别差异均无统计学意义(P均>0.05)。房颤组的LAD[(44.2±5.8)mm比(35.4±4.4)mm]、V-EAT[(122.1±42.0)cm3比(91.6±34.5)cm3]、LA-EAT FDG SUVmax[(1.6±0.3)比(1.4±0.2)]均高于对照组,LVEF[(60.1±4.7)%比(63.9±2.9)%]低于对照组(P均<0.001)。多因素logistic回归分析显示LAD(OR=1.340,95%CI 1.195~1.502)、V-EAT(OR=1.016,95%CI 1.001~1.031)、LA-EAT FDG SUVmax(OR=1.375,95%CI 1.095~1.723)与房颤正相关,LVEF(OR=0.781,95%CI 0.659~0.926)与房颤负相关(P均<0.05)。LA-EAT FDG SUVmax判断房颤的ROC曲线下面积为0.680(95%CI 0.597~0.764,P<0.001),LA-EAT FDG SUVmax判断房颤的最佳界值为1.415(灵敏度为65.4%,特异度为61.5%)。在校正高密度脂蛋白胆固醇、LVEF、LAD、V-EAT后,LA-EAT FDG SUVmax≥1.415与房颤独立相关(OR=2.982,95%CI 1.122~7.926,P=0.010)。 结论: 18F-FDG PET/CT测量的LA-EAT炎症活性是房颤的影响因素,LA-EAT炎症活性增高与房颤正相关。.