前侧位与前後位电极位置用于心房颤动复律的比较
该多中心随机试验将468例择期复律的房颤患者分配至前侧位或前后位电极位置,发现前侧位首次电击后窦性心律比例更高(54% vs 33%,风险差22个百分点[95%CI 13-30],P<0.001),最终复律成功率也更高(93% vs 85%,风险差7个百分点[95%CI 2-12]),安全性无显著差异。
要点
- 前侧位电极首次电击复律成功率显著高于前后位。
- 前侧位最终复律成功率亦更高,安全性无差异。
- 双相波复律房颤时前侧位优于前后位。
核心结论
- 前侧位电极位置比前后位更有效用于双相波复律房颤,安全性无显著差异。
研究设计与样本
- 多中心、研究者发起、开放标签随机试验,纳入468例择期复律的房颤患者。
主要发现
- 首次电击后窦性心律:前侧位126例(54%)vs 前后位77例(33%),风险差22个百分点(95%CI 13-30),P<0.001。
- 最终电击后窦性心律:前侧位216例(93%)vs 前后位200例(85%),风险差7个百分点(95%CI 2-12)。
- 安全性结局(心律失常、皮肤发红、疼痛)组间无显著差异。
临床怎么用
- 房颤双相波复律时可优先选择前侧位电极位置以提高成功率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Smaller randomized studies have reported conflicting results regarding the optimal electrode position for cardioverting atrial fibrillation. However, anterior-posterior electrode positioning is widely used as a standard and believed to be superior to anterior-lateral electrode positioning. Therefore, we aimed to compare anterior-lateral and anterior-posterior electrode positioning for cardioverting atrial fibrillation in a multicenter randomized trial. METHODS: In this multicenter, investigator-initiated, open-label trial, we randomly assigned patients with atrial fibrillation scheduled for elective cardioversion to either anterior-lateral or anterior-posterior electrode positioning. The primary outcome was the proportion of patients in sinus rhythm after the first shock. The secondary outcome was the proportion of patients in sinus rhythm after up to 4 shocks escalating to maximum energy. Safety outcomes were any cases of arrhythmia during or after cardioversion, skin redness, and patient-reported periprocedural pain. RESULTS: We randomized 468 patients. The primary outcome occurred in 126 patients (54%) assigned to the anterior-lateral electrode position and in 77 patients (33%) assigned to the anterior-posterior electrode position (risk difference, 22 percentage points [95% CI, 13-30]; P<0.001). The number of patients in sinus rhythm after the final cardioversion shock was 216 (93%) assigned to anterior-lateral electrode positioning and 200 (85%) assigned to anterior-posterior electrode positioning (risk difference, 7 percentage points [95% CI, 2-12]). There were no significant differences between groups in any safety outcomes. CONCLUSIONS: Anterior-lateral electrode positioning was more effective than anterior-posterior electrode positioning for biphasic cardioversion of atrial fibrillation. There were no significant differences in any safety outcome. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03817372.
引用
- Schmidt AS, Lauridsen KG, Møller DS, et al. Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation. Circulation. 2021. PMID: 34814700. doi:10.1161/CIRCULATIONAHA.121.056301
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。