双源CT动态心肌灌注成像对冠心病的诊断效能
这项前瞻性多中心研究纳入174例临床转诊行有创冠状动脉造影(ICA)的疑似或已知冠心病患者,在ICA前用双源CT完成冠状动脉CTA和动态CTP。以ICA联合血流储备分数(FFR)为参考,在157例完成方案者中,动态CTP联合CTA较单用CTA提高了患者水平诊断的曲线下面积(0.65升至0.74,P=0.011),但敏感性下降、特异性与总体准确率提高。
要点
- 动态CTP联合CTA较单用CTA提高患者水平诊断曲线下面积(0.65升至0.74,P=0.011)。
- 联合策略敏感性下降(93%对72%,P<0.001),特异性提高(36%对75%,P<0.001)。
- 联合策略总体准确率提高(64%对74%,P<0.001)。
核心结论
- 在疑似或已知冠心病患者中,冠状动脉CTA联合动态CTP较单用CTA能更准确识别血流动力学显著狭窄。
研究设计与样本
- 前瞻性多中心研究,7个中心纳入174例临床转诊行ICA的疑似或已知冠心病患者。
- ICA前用双源CT完成CTA和动态CTP;26%至90%冠状动脉直径狭窄者行ICA时测FFR。
- 157例完成研究方案,血流动力学显著狭窄定义为FFR<0.8或ICA示狭窄>90%。
主要发现
- 157例中76例(48%)存在血流动力学显著狭窄,442支血管中112支(25%)存在显著狭窄。
- 患者水平曲线下面积由单用CTA的0.65(95%CI:0.57-0.72)升至联合动态CTP的0.74(95%CI:0.66-0.81;P=0.011)。
- 联合策略较单用CTA敏感性下降(93%对72%;P<0.001),特异性提高(36%对75%;P<0.001)。
- 联合策略总体准确率提高(64%对74%;P<0.001)。
临床怎么用
- 对临床转诊行ICA的疑似或已知冠心病患者,可在冠状动脉CTA基础上加做动态CTP以辅助识别血流动力学显著狭窄。
- 采用联合策略需权衡敏感性下降,避免遗漏血流动力学显著狭窄。
局限性
- 该方法的临床意义尚需进一步研究,包括其对改善预后的作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Single-center studies indicated a high diagnostic accuracy of dynamic computed tomography perfusion (CTP) imaging in the diagnosis of coronary artery disease (CAD). OBJECTIVES: This prospective multicenter study determined the diagnostic performance of combined coronary computed tomography angiography (CTA) and CTP for detecting hemodynamically significant CAD defined by invasive coronary angiography (ICA) with fractional flow reserve (FFR). METHODS: Seven centers enrolled 174 patients with suspected or known CAD who were clinically referred for ICA. CTA and dynamic CTP were performed using dual-source CT before ICA. FFR was done as part of ICA in the case of 26% to 90% coronary diameter stenosis. Hemodynamically significant stenosis was defined as FFR of <0.8 or >90% stenosis on ICA. RESULTS: The study protocol was completed in 157 participants, and hemodynamically significant stenosis was detected in 76 of 157 patients (48%) and 112 of 442 vessels (25%). According to receiver-operating characteristic curve analysis, adding dynamic CTP to CTA significantly increased the area under the curve from 0.65 (95% CI: 0.57-0.72) to 0.74 (95% CI: 0.66-0.81; P = 0.011) on the patient level, with decreased sensitivity (93% vs 72%; P < 0.001), improved specificity (36% vs 75%; P < 0.001), and improved overall accuracy (64% vs 74%; P < 0.001). CONCLUSIONS: In this prospective multicenter study on dynamic CTP, the combination of anatomic assessment with coronary CTA and functional evaluation with dynamic CTP allowed more accurate identification of hemodynamically significant CAD compared with CTA alone. However, the clinical significance of this approach needs to be further investigated, including its usefulness in improving prognosis. (Assessment of Myocardial Perfusion Linked to Infarction and Fibrosis Explored With Dual-Source CT [AMPLIFiED]; UMIN000016353).
引用
- Kitagawa K, Nakamura S, Ota H, et al. Diagnostic Performance of Dynamic Myocardial Perfusion Imaging Using Dual-Source Computed Tomography. J Am Coll Cardiol. 2021. PMID: 34763770. doi:10.1016/j.jacc.2021.08.067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。