文献速递脑血管病神经重症与神经感染

用于脑出血血肿体积检测的稳健深度学习分割方法

A Robust Deep Learning Segmentation Method for Hematoma Volumetric Detection in Intracerebral Hemorrhage.
PubMed 文献 · Stroke · 2021-10-04

DR-UNet分割性能与专家临床医生相似,内部测试Dice为0.861±0.139,外部测试Dice为0.874±0.130;血肿体积测量与手动分割强相关(R2=0.9979;P<0.0001)。在形状不规则血肿及硬膜下/硬膜外血肿组中,DR-UNet的稳健性优于UNet。

要点

  • DR-UNet在CT上分割脑出血血肿的Dice达0.861±0.139(内部测试)和0.874±0.130(外部测试),与专家临床医生相似。
  • DR-UNet测量的血肿体积与手动分割强相关(R2=0.9979;P<0.0001)。
  • 在形状不规则血肿及硬膜下/硬膜外血肿中,DR-UNet稳健性优于UNet。

核心结论

  • DR-UNet能从脑出血患者CT扫描中分割血肿并量化血肿体积,准确性和效率优于现有主要方法,性能与专家临床医生相似。

研究设计与样本

  • 开发了降维UNet(DR-UNet)模型用于CT图像分割和血肿体积测量。
  • 另选13例不规则血肿、11例硬膜下和硬膜外血肿及50例不同血肿体积(<30、30-60、>60 mL三组)病例评估稳健性。
  • 分割性能与UNet、模糊聚类法和活动轮廓法比较;体积测量性能与UNet和Coniglobus公式法比较。

主要发现

  • 内部测试数据Dice为0.861±0.139,外部测试数据Dice为0.874±0.130,与专家临床医生相似。
  • DR-UNet测量的血肿体积与手动分割强相关(R2=0.9979;P<0.0001)。
  • 在不规则血肿组及硬膜下和硬膜外血肿组中,DR-UNet在血肿分割和体积测量上均比UNet更稳健。
  • 3个不同血肿体积组间的分割准确性无统计学显著性差异。

临床怎么用

  • DR-UNet可快速、准确地从CT图像分割血肿并测量体积,性能与专家临床医生相似且效率更高。
  • 对不规则血肿及硬膜下/硬膜外血肿等复杂情况稳健性较好,有助于临床血肿体积评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Hematoma volume (HV) is a significant diagnosis for determining the clinical stage and therapeutic approach for intracerebral hemorrhage (ICH). The aim of this study is to develop a robust deep learning segmentation method for the fast and accurate HV analysis using computed tomography. METHODS: A novel dimension reduction UNet (DR-UNet) model was developed for computed tomography image segmentation and HV measurement. Two data sets, 512 ICH patients with 12 568 computed tomography slices in the retrospective data set and 50 ICH patients with 1257 slices in the prospective data set, were used for network training, validation, and internal and external testing. Moreover, 13 irregular hematoma cases, 11 subdural and epidural hematoma cases, and 50 different HV cases into 3 groups (<30, 30-60, and >60 mL) were selected to further evaluate the robustness of DR-UNet. The image segmentation performance of DR-UNet was compared with those of UNet, the fuzzy clustering method, and the active contour method. The HV measurement performance was compared using DR-UNet, UNet, and the Coniglobus formula method. RESULTS: Using DR-UNet, the segmentation model achieved a performance similar to that of expert clinicians in 2 independent test data sets containing internal testing data (Dice of 0.861±0.139) and external testing data (Dice of 0.874±0.130). The HV measurement derived from DR-UNet was strongly correlated with that from manual segmentation (R2=0.9979; P<0.0001). In the irregularly shaped hematoma group and the subdural and epidural hematoma group, DR-UNet was more robust than UNet in both hematoma segmentation and HV measurement. There is no statistical significance in segmentation accuracy among 3 different HV groups. CONCLUSIONS: DR-UNet can segment hematomas from the computed tomography scans of ICH patients and quantify the HV with better accuracy and greater efficiency than the main existing methods and with similar performance to expert clinicians. Due to robust performance and stable segmentation on different ICHs, DR-UNet could facilitate the development of deep learning systems for a variety of clinical applications.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Yu N, Yu H, Li H, et al. A Robust Deep Learning Segmentation Method for Hematoma Volumetric Detection in Intracerebral Hemorrhage. Stroke. 2021. PMID: 34601899. doi:10.1161/STROKEAHA.120.032243

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。