文献速递脑血管病

Tmax图可准确快速识别远端中等血管闭塞

Distal Medium Vessel Occlusions Can Be Accurately and Rapidly Detected Using Tmax Maps.
PubMed 文献 · Stroke · 2021-07-08

以CTA为参考标准,该征象敏感度100%、特异度87.8%,AUC为0.939;4名不同经验读者用Tmax图的诊断准确性和速度均显著优于CTA(P<0.001)。

要点

  • 供血区Tmax延迟识别DMVO敏感度100%、特异度87.8%,AUC 0.939。
  • 不同经验读者用Tmax图检测DMVO的敏感度均>95%、特异度>84%。
  • Tmax图判读的准确性与速度均显著优于CTA(P<0.001)。

核心结论

  • 供血区Tmax延迟对DMVO具有完美敏感度和高特异度,Tmax图可准确快速识别DMVO患者。

研究设计与样本

  • 两名有经验读者共识判读所有患者Tmax图上的供血区Tmax延迟,以两名神经影像专家结合全部影像判读的CTA为参考标准。
  • 另4名不同经验读者在两次独立计时判读中分别评估Tmax图与CTA,比较诊断性能与速度。

主要发现

  • 供血区Tmax延迟识别DMVO的敏感度为100%(CI95,94.9%–100%),特异度为87.8%(CI95,83.6%–91.3%)。
  • AUC为0.939(CI95,0.920–0.957)。
  • 4名读者用Tmax图检测DMVO的敏感度均>95%、特异度均>84%,诊断准确性(AUC)与速度均显著高于CTA(P<0.001)。

关键数值与推荐

  • 供血区Tmax延迟:敏感度100%(CI95,94.9%–100%),特异度87.8%(CI95,83.6%–91.3%),AUC 0.939(CI95,0.920–0.957)。
  • 读者层面:Tmax图检测DMVO敏感度>95%、特异度>84%,准确性及速度优于CTA(P<0.001)。

临床怎么用

  • 可将Tmax图作为分诊筛查工具,快速识别可能适合血管内取栓评估的DMVO患者。
  • 即使经验较少的读者也能准确快速判读Tmax图,假阳性原因易于识别并排除。

局限性

  • 为回顾性研究设计。
  • 原文摘要未报告纳入时间范围、单中心或多中心信息及其他局限性细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Distal medium vessel occlusions (DMVOs) are increasingly considered for endovascular thrombectomy but are difficult to detect on computed tomography angiography (CTA). We aimed to determine whether time-to-maximum of tissue residue function (Tmax) maps, derived from CT perfusion, can be used as a triage screening tool to accurately and rapidly identify patients with DMVOs. METHODS: Consecutive code stroke patients who underwent multimodal CT were screened retrospectively. Two experienced readers evaluated all patients’ Tmax maps in consensus for presence of delay in an arterial territory (territorial Tmax delay). The diagnostic accuracy of this surrogate for identifying DMVOs was determined using receiver-operating characteristic analysis. CTA, interpreted by 2 experienced neuroradiologists with access to all imaging data, served as the reference standard. Diagnostic performance of 4 other readers with different levels of experience for identifying DMVOs on Tmax versus CTA was also assessed. These readers independently assessed patients’ Tmax maps and CTAs in 2 separate timed sessions, and areas under the receiver-operating characteristic curves were compared using the DeLong algorithm. The Wilcoxon signed-rank test was used to comparatively assess diagnostic speed. RESULTS: Three hundred seventy-three code stroke patients (median age, 70 years; 56% male, 70 with a DMVO) were included. Territorial Tmax delay had a sensitivity of 100% (CI95, 94.9%–100%) and specificity of 87.8% (CI95, 83.6%–91.3%) for presence of a DMVO, yielding an area under the receiver-operating characteristic curves of 0.939 (CI95, 0.920–0.957). All 4 readers achieved sensitivity >95% and specificity >84% for detecting DMVOs using Tmax maps, with diagnostic accuracy (area under the receiver-operating characteristic curves) and speed that were significantly (P<0.001) higher than on CTA. CONCLUSIONS: Territorial Tmax delay had perfect sensitivity and high specificity for a DMVO. Tmax maps were accurately and rapidly interpreted by even inexperienced readers, and causes of false positives are easy to recognize and dismiss. These findings encourage the use of Tmax to identify patients with DMVOs.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Amukotuwa SA, Wu A, Zhou K, et al. Distal Medium Vessel Occlusions Can Be Accurately and Rapidly Detected Using Tmax Maps. Stroke. 2021. PMID: 34233460. doi:10.1161/STROKEAHA.120.032941

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。