数字外周动脉张力测量与心血管疾病事件:Framingham心脏研究
本研究在Framingham心脏研究3865名参与者中评估指尖外周动脉张力(PAT)测量与首次主要心血管事件的关系。中位随访9.2年,270人(7%)发生新发心血管事件。基线脉搏振幅和PAT比值与复合心血管事件无显著相关,但较高PAT比值与较低卒中风险相关(HR 0.76,95%CI 0.61–0.94,P=0.013),尤其与缺血性卒中风险降低相关(HR 0.68,95%CI 0.53–0.86,P=0.001)。
要点
- 指尖PAT比值与复合心血管事件无显著相关。
- 较高PAT比值与较低卒中风险独立相关。
- PAT比值与缺血性卒中风险降低相关更显著。
核心结论
- 数字PAT测量可能作为社区人群卒中风险的标志物。
研究设计与样本
- 前瞻性队列研究,纳入Framingham心脏研究后代和第三代参与者3865人(平均年龄55±14岁,52%女性)。
主要发现
- 随访中位9.2年(范围0.04–10.0年),270人(7%)发生新发心血管事件。
- 多变量调整后,基线脉搏振幅与复合心血管事件无显著相关(HR 1.04,95%CI 0.90–1.21,P=0.57)。
- PAT比值与复合心血管事件无显著相关(HR 0.95,95%CI 0.84–1.08,P=0.43)。
- 较高PAT比值与较低卒中风险相关(HR 0.76,95%CI 0.61–0.94,P=0.013)。
- 较高PAT比值与较低缺血性卒中风险相关(HR 0.68,95%CI 0.53–0.86,P=0.001)。
临床怎么用
- 指尖PAT测量或可用于社区人群卒中风险分层,但需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Novel noninvasive measures of vascular function are emerging as subclinical markers for cardiovascular disease (CVD) and may be useful to predict CVD events. The purpose of our prospective study was to assess associations between digital peripheral arterial tonometry (PAT) measures and first-onset major CVD events in a sample of FHS (Framingham Heart Study) participants. METHODS: Using a fingertip PAT device, we assessed pulse amplitude in Framingham Offspring and Third Generation participants (n=3865; mean age, 55±14 years; 52% women) at baseline and in 30-second intervals for 4 minutes during reactive hyperemia. The PAT ratio (relative hyperemia index) was calculated as the post-to-pre occlusion pulse signal ratio in the occluded arm, relative to the same ratio in the control (nonoccluded) arm, and corrected for baseline vascular tone. Baseline pulse amplitude and PAT ratio during hyperemia are measures of pressure pulsatility and microvascular function in the finger, respectively. We used Cox proportional hazards regression to relate PAT measures in the fingertip to incident CVD events. RESULTS: During follow-up (median, 9.2 years; range, 0.04–10.0 years), 270 participants (7%) experienced new-onset CVD events (n=270). In multivariable models adjusted for cardiovascular risk factors, baseline pulse amplitude (hazard ratio [HR] per 1 SD, 1.04 [95% CI, 0.90–1.21]; P=0.57) and PAT ratio (HR, 0.95 [95% CI, 0.84–1.08]; P=0.43) were not significantly related to incident composite CVD events, including myocardial infarction or heart failure. However, higher PAT ratio (HR, 0.76 [95% CI, 0.61–0.94]; P=0.013), but not baseline pulse amplitude (HR, 1.15 [95% CI, 0.89–1.49]; P=0.29), was related to lower risk for incident stroke. In a sensitivity analysis by stroke subtype, higher PAT ratio was related to lower risk of incident ischemic stroke events (HR, 0.68 [95% CI, 0.53–0.86]; P=0.001). CONCLUSIONS: Novel digital PAT measures may represent a marker of stroke risk in the community.
引用
- Cooper LL, Wang N, Beiser AS, et al. Digital Peripheral Arterial Tonometry and Cardiovascular Disease Events: The Framingham Heart Study. Stroke. 2021. PMID: 34192894. doi:10.1161/STROKEAHA.120.031102
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。