基线SD-OCT视网膜层厚度与多发性硬化长期残疾恶化的关联
该前瞻性纵向研究纳入132例多发性硬化患者,基线及中位10.4年后进行SD-OCT和EDSS评估。排除既往视神经炎眼后,基线平均GCIPL厚度<70µm与有意义的EDSS恶化风险约4倍升高独立相关,提示单时间点SD-OCT或有助于治疗决策。
要点
- 基线GCIPL厚度<70µm与长期EDSS恶化风险约4倍升高独立相关。
- 基线GCIPL厚度<70µm也与低对比度视力恶化风险约3倍升高相关。
- 单时间点SD-OCT或可辅助多发性硬化个体化治疗决策。
核心结论
- 基线SD-OCT测量的GCIPL厚度较低与多发性硬化长期残疾恶化独立相关。
研究设计与样本
- 前瞻性纵向研究,纳入132例多发性硬化患者,基线及中位10.4年后进行SD-OCT、EDSS和视力评估。
主要发现
- 排除既往视神经炎眼后,基线平均GCIPL厚度<70µm者有意义EDSS恶化的校正OR为3.97(95%CI 1.24-12.70;p=0.02)。
- 基线平均GCIPL厚度<70µm者低对比度视力恶化的校正OR为2.93(95%CI 1.40-6.13;p=0.04)。
关键数值与推荐
- 有意义EDSS恶化定义为基线EDSS<6.0时增加≥2.0或基线EDSS≥6.0时增加≥1.0。
- GCIPL厚度阈值70µm为基线所有眼平均GCIPL厚度。
临床怎么用
- SD-OCT单时间点评估GCIPL厚度可能有助于指导多发性硬化个体化治疗决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate whether a retinal spectral-domain optical coherence tomography (SD-OCT) assessment at baseline is associated with long-term disability worsening in people with multiple sclerosis (PwMS), we performed SD-OCT and Expanded Disability Status Scale (EDSS) assessments among 132 PwMS at baseline and at a median of 10 years later. METHODS: In this prospective, longitudinal study, participants underwent SD-OCT, EDSS, and visual acuity (VA) assessments at baseline and at follow-up. Statistical analyses were performed using generalized linear regression models, adjusted for age, sex, race, multiple sclerosis (MS) subtype, and baseline disability. We defined clinically meaningful EDSS worsening as an increase of ≥2.0 if baseline EDSS score was <6.0 or an increase of ≥1.0 if baseline EDSS score was ≥6.0. RESULTS: A total of 132 PwMS (mean age 43 years; 106 patients with relapsing-remitting MS) were included in analyses. Median duration of follow-up was 10.4 years. In multivariable models excluding eyes with prior optic neuritis, relative to patients with an average baseline ganglion cell + inner plexiform layer (GCIPL) thickness ≥70 µm (the mean GCIPL thickness of all eyes at baseline), an average baseline GCIPL thickness <70 µm was associated with a 4-fold increased odds of meaningful EDSS worsening (adjusted odds ratio [OR] 3.97, 95% confidence interval [CI] 1.24-12.70; p = 0.02) and an almost 3-fold increased odds of low-contrast VA worsening (adjusted OR 2.93, 95% CI 1.40-6.13; p = 0.04). CONCLUSIONS: Lower baseline GCIPL thickness on SD-OCT is independently associated with long-term disability worsening in MS. Accordingly, SD-OCT at a single time point may help guide therapeutic decision-making among individual PwMS. CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that lower baseline GCIPL thickness on SD-OCT is independently associated with long-term disability worsening in MS.
引用
- Lambe J, Fitzgerald KC, Murphy OC, et al. Association of Spectral-Domain OCT With Long-term Disability Worsening in Multiple Sclerosis. Neurology. 2021. PMID: 33653904. doi:10.1212/WNL.0000000000011788
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。