文献速递脑血管病认知障碍与痴呆

MRI白质高信号标志物与长期死亡及缺血性卒中风险的关联:SMART-MR研究

Association of White Matter Hyperintensity Markers on MRI and Long-term Risk of Mortality and Ischemic Stroke: The SMART-MR Study.
PubMed 文献 · Neurology · 2021-03-16

该研究纳入999例有明确动脉疾病的患者,基于基线脑MRI自动算法提取白质高信号(WMH)的体积、类型和形状标志物,中位随访12.5年。Cox回归显示,较大的脑室周围或融合性WMH体积、融合性WMH类型及更不规则的WMH形状均与血管性死亡、非血管性死亡和缺血性卒中的长期风险独立相关。

要点

  • 脑室周围或融合性WMH体积每增加1个自然对数单位,血管性死亡风险HR 1.29,缺血性卒中风险HR 1.53。
  • 融合性WMH类型与血管性死亡(HR 1.89)、非血管性死亡(HR 1.65)及缺血性卒中(HR 2.83)风险升高独立相关。
  • WMH凹度指数每增加1个标准差,血管性死亡HR 1.20、非血管性死亡HR 1.21、缺血性卒中HR 1.28。

核心结论

  • 在明确动脉疾病患者中,WMH体积、类型和形状与长期死亡及缺血性卒中风险独立相关。

研究设计与样本

  • 研究为SMART-MR队列分析,纳入999例有明确动脉疾病的连续患者,基线脑MRI自动算法提取WMH标志物,中位随访12.5年(范围0.2-16.0年)。

主要发现

  • 脑室周围或融合性WMH体积每增加1个自然对数单位,血管性死亡HR 1.29(95%CI 1.13-1.47),缺血性卒中HR 1.53(95%CI 1.26-1.86)。
  • 融合性WMH类型与血管性死亡HR 1.89(95%CI 1.15-3.11)、非血管性死亡HR 1.65(95%CI 1.01-2.73)及缺血性卒中HR 2.83(95%CI 1.36-5.87)相关。
  • WMH凹度指数每增加1个标准差,血管性死亡HR 1.20(95%CI 1.05-1.38)、非血管性死亡HR 1.21(95%CI 1.03-1.42)、缺血性卒中HR 1.28(95%CI 1.05-1.55)。

临床怎么用

  • 对明确动脉疾病患者,可结合脑MRI上WMH体积、融合性类型及不规则形状等标志物辅助评估长期死亡和缺血性卒中风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine whether white matter hyperintensity (WMH) markers on MRI are associated with long-term risk of mortality and ischemic stroke. METHODS: We included consecutive patients with manifest arterial disease enrolled in the Second Manifestations of Arterial Disease-Magnetic Resonance (SMART-MR) study. We obtained WMH markers (volume, type, and shape) from brain MRI scans performed at baseline using an automated algorithm. During follow-up, occurrence of death and ischemic stroke was recorded. Using Cox regression, we investigated associations of WMH markers with risk of mortality and ischemic stroke, adjusting for demographics, cardiovascular risk factors, and cerebrovascular disease. RESULTS: We included 999 patients (59 ± 10 years; 79% male) with a median follow-up of 12.5 years (range 0.2-16.0 years). A greater periventricular or confluent WMH volume was independently associated with a greater risk of vascular death (hazard ratio [HR] 1.29, 95% confidence interval [CI] 1.13-1.47) for a 1-unit increase in natural log-transformed WMH volume and ischemic stroke (HR 1.53, 95% CI 1.26-1.86). A confluent WMH type was independently associated with a greater risk of vascular (HR 1.89, 95% CI 1.15-3.11) and nonvascular death (HR 1.65, 95% CI 1.01-2.73) and ischemic stroke (HR 2.83, 95% CI 1.36-5.87). A more irregular shape of periventricular or confluent WMH, as expressed by an increase in concavity index, was independently associated with a greater risk of vascular (HR 1.20, 95% CI 1.05-1.38 per SD increase) and nonvascular death (HR 1.21, 95% CI 1.03-1.42) and ischemic stroke (HR 1.28, 95% CI 1.05-1.55). CONCLUSIONS: WMH volume, type, and shape are associated with long-term risk of mortality and ischemic stroke in patients with manifest arterial disease.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Ghaznawi R, Geerlings MI, Jaarsma-Coes M, et al. Association of White Matter Hyperintensity Markers on MRI and Long-term Risk of Mortality and Ischemic Stroke: The SMART-MR Study. Neurology. 2021. PMID: 33727406. doi:10.1212/WNL.0000000000011827

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。