文献速递脑血管病

非增强CT e-Stroke梗死体积与RAPID CTP在预测再灌注后梗死体积上相似

Noncontrast Computed Tomography e-Stroke Infarct Volume Is Similar to RAPID Computed Tomography Perfusion in Estimating Postreperfusion Infarct Volumes.
PubMed 文献 · Stroke · 2021-01-12

结果显示两者与最终梗死体积相关性相似(R=0.52 vs 0.43),且均与90天良好预后独立相关(aOR均为0.98)。结论认为NCCT e-Stroke可作为高级影像受限中心的可行替代。

要点

  • NCCT e-Stroke与CTP核心体积中度相关(R=0.44)。
  • 两者对最终梗死体积预测相关性相似(R=0.52 vs 0.43)。
  • 早期和晚期时间窗内两者性能相似。

核心结论

  • NCCT e-Stroke软件在评估再灌注后最终梗死体积和功能结局方面与RAPID CTP表现相似。
  • NCCT e-Stroke体积可能成为高级影像受限中心的可行替代方案。

研究设计与样本

  • 纳入标准为基线NCCT e-Stroke和RAPID CTP均可测缺血核心体积、有最终梗死体积测量且取栓后实现完全再灌注(mTICI 2c-3)。

主要发现

  • e-Stroke和CTP中位缺血核心体积分别为38.4 mL(21.8-58)和5 mL(0-17.7),中位最终梗死体积为22.2 mL(9.1-56.2)。
  • e-Stroke与CTP核心体积中度相关(R=0.44;P<0.001)。
  • e-Stroke核心与最终梗死体积(R=0.52;P<0.001)及CTP核心与最终梗死体积(R=0.43;P<0.001)均呈中度相关。
  • 亚组分析显示早期和晚期(>6小时)治疗时间窗内e-Stroke与CTP性能相似。
  • 多变量分析显示e-Stroke NCCT基线缺血核心体积(aOR 0.98 [95%CI 0.97-0.99])和RAPID CTP缺血核心体积(aOR 0.98 [95%CI 0.97-0.99])均独立且可比地与90天良好结局(mRS 0-2)相关。

临床怎么用

  • 在缺乏CTP等高级影像的中心,可考虑使用NCCT e-Stroke软件评估缺血核心体积。
  • NCCT e-Stroke评估结果可用于预测再灌注后梗死体积和90天功能结局。

局限性

  • 原文未明确报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: The e-Stroke Suite software (Brainomix, Oxford, United Kingdom) is a tool designed for the automated quantification of The Alberta Stroke Program Early CT Score and ischemic core volumes on noncontrast computed tomography (NCCT). We sought to compare the prediction of postreperfusion infarct volumes and the clinical outcomes across NCCT e-Stroke software versus RAPID (IschemaView, Menlo Park, CA) computed tomography perfusion measurements. METHODS: All consecutive patients with anterior circulation large vessel occlusion stroke presenting at a tertiary care center between September 2010 and November 2018 who had available baseline infarct volumes on both NCCT e-Stroke Suite software and RAPID CTP as well as final infarct volume (FIV) measurements and achieved complete reperfusion (modified Thrombolysis in Cerebral Infarction scale 2c-3) post-thrombectomy were included. The associations between estimated baseline ischemic core volumes and FIV as well as 90-day functional outcomes were assessed. RESULTS: Four hundred seventy-nine patients met inclusion criteria. Median age was 64 years (55-75), median e-Stroke and computed tomography perfusion ischemic core volumes were 38.4 (21.8-58) and 5 (0-17.7) mL, respectively, whereas median FIV was 22.2 (9.1-56.2) mL. The correlation between e-Stroke and CTP ischemic core volumes was moderate (R=0.44; P<0.001). Similarly, moderate correlations were observed between e-Stroke software ischemic core and FIV (R=0.52; P<0.001) and CTP core and FIV (R=0.43; P<0.001). Subgroup analysis showed that e-Stroke software and CTP performance was similar in the early and late (>6 hours) treatment windows. Multivariate analysis showed that both e-Stroke software NCCT baseline ischemic core volume (adjusted odds ratio, 0.98 [95% CI, 0.97-0.99]) and RAPID CTP ischemic core volume (adjusted odds ratio, 0.98 [95% CI, 0.97-0.99]) were independently and comparably associated with good outcome (modified Rankin Scale score of 0-2) at 90 days. CONCLUSIONS: NCCT e-Stroke Suite software performed similarly to RAPID CTP in assessing postreperfusion FIV and functional outcomes for both early- and late-presenting patients. NCCT e-Stroke volumes seems to represent a viable alternative in centers where access to advanced imaging is limited. Moreover, the future development of fusion maps of NCCT and CTP ischemic core estimates may improve upon the current performance of these tools as applied in isolation.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Bouslama M, Ravindran K, Harston G, et al. Noncontrast Computed Tomography e-Stroke Infarct Volume Is Similar to RAPID Computed Tomography Perfusion in Estimating Postreperfusion Infarct Volumes. Stroke. 2021. PMID: 33430633. doi:10.1161/STROKEAHA.120.031651

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。