非房颤患者完全P波消失:被忽视的高卒中风险人群
结果显示CPWD反映广泛心房电静默和机械功能严重受损,与血栓栓塞强烈相关,所有患者接受华法林治疗,中位随访42.0个月期间2例因停用华法林发生大面积缺血性卒中。
要点
- 非房颤患者出现完全P波消失提示广泛心房电静默和机械功能严重受损。
- CPWD与血栓栓塞强烈相关,8例有卒中史、3例存在心房血栓。
- 建议对CPWD患者进行抗凝治疗,停药可致大面积缺血性卒中。
核心结论
- CPWD反映广泛心房电静默和显著受损的心房机械功能,与血栓栓塞强烈相关。
- 提出CPWD-心房麻痹-卒中临床三联征,建议此类患者接受抗凝治疗。
研究设计与样本
- 所有患者接受经食管超声心动图或心脏CT筛查心房血栓,通过电生理检查和三维电解剖标测评估心房电活动和瘢痕,多模态心脏影像评估心脏结构和功能。
主要发现
- 脉冲波二尖瓣流入道多普勒显示18例A波消失、5例A波减弱;三尖瓣流入道多普勒显示19例A波消失、4例A波减弱。
- 入组时8例有既往卒中,3例存在心房血栓。
- 中位随访42.0个月期间,2例因停用华法林发生大面积缺血性卒中。
关键数值与推荐
- 所有患者均处方华法林。
临床怎么用
- 对非房颤患者出现完全P波消失应警惕高卒中风险,建议进行心房血栓筛查并考虑抗凝治疗。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Complete P wave disappearance (CPWD) in patients without atrial fibrillation is an uncommon clinical phenomenon. We aimed to study the relationship between CPWD and thromboembolism. METHODS: Between July 2007 and December 2018, consecutive patients with CPWD on surface ECG and 24-hour Holter recording were recruited into the study from 4 centers in China. All recruited patients underwent transesophageal echocardiography or cardiac computed tomography to screen for atrial thrombus. Atrial electrical activity and scar were assessed by electrophysiological study (EPS) and 3-dimensional electroanatomic mapping. Cardiac structure and function were assessed by multimodality cardiac imaging. RESULTS: Twenty-three consecutive patients (8 male; mean age 48.5±14.7 years) with CPWD were included. Only 3 patients demonstrated complete atrial electrical silence with atrial noncapture. Thirteen patients who had invasive atrial endocardial mapping demonstrated extensive scar. Pulse-wave mitral inflow Doppler demonstrated absent and dampened A waves in 18 and 5 patients, respectively. Pulse-wave tricuspid inflow Doppler showed absent and dampened A waves in 19 and 4 patients, respectively. Upon recruitment, 8 patients had previous stroke and 3 patients had atrial thrombus. Warfarin was prescribed to all patients. During median follow-up of 42.0 months, 2 patients developed massive ischemic stroke due to warfarin discontinuation. CONCLUSIONS: Our study suggested that CPWD reflects extensive atrial electrical silence and significantly impaired atrial mechanical function. It was strongly associated with thromboembolism and the clinical triad of CPWD-atrial paralysis-stroke was proposed. Anticoagulation should be recommended in such patients.
引用
- Liu H, Li M, Li C, et al. Nonatrial Fibrillation Patients With Complete P Wave Disappearance: An Overlooked Population With High Stroke Risk. Stroke. 2021. PMID: 33504191. doi:10.1161/STROKEAHA.120.031666
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。