文献速递认知障碍与痴呆

尸检证实的痴呆中淀粉样蛋白与FDG PET的诊断准确性比较

Diagnostic Accuracy of Amyloid versus 18 F-Fluorodeoxyglucose Positron Emission Tomography in Autopsy-Confirmed Dementia.
PubMed 文献 · Ann Neurol · 2020-12-07

本研究在101例痴呆患者中比较生前PIB-PET与FDG-PET视觉判读对中-高AD神经病理改变的诊断准确性,以尸检为金标准。PIB-PET敏感性高于FDG-PET(96% vs 80%),特异性相当(86% vs 84%)。两者判读一致时联合敏感性和特异性接近100%,不一致时应考虑混合病理。

要点

  • PIB-PET检测中-高ADNC的敏感性显著高于FDG-PET(96% vs 80%)。
  • PIB-PET与FDG-PET特异性相当(86% vs 84%)。
  • 两者判读一致时联合敏感性97%、特异性98%,不一致时需考虑混合病理。

核心结论

  • 在 enriched 样本中,PIB-PET对中-高ADNC的敏感性高于FDG-PET,特异性相似。
  • PIB与FDG判读一致时敏感性和特异性接近100%,不一致时应考虑混合病理。

研究设计与样本

  • 101例参与者生前接受PIB-PET和FDG-PET,死后进行神经病理评估。
  • PET图像由3名对临床信息盲法的判读者视觉判读。
  • 神经病理诊断采用研究标准,多数判读结果与中-高ADNC比较。

主要发现

  • 尸检显示32例原发性AD,56例非AD神经病理(主要为FTLD),13例混合AD/FTLD病理。
  • PIB检测中-高ADNC的敏感性96%(95%CI=89-100%),FDG为80%(95%CI=68-92%),p=0.02。
  • PIB特异性86%(95%CI=76-95%),FDG特异性84%(95%CI=74-93%),p=0.80。
  • 77/101例PIB与FDG判读一致,联合敏感性97%(95%CI=92-100%),特异性98%(95%CI=93-100%)。
  • 24例判读不一致者中9例存在AD与非AD病理共存。

关键数值与推荐

  • PIB-PET视觉判读分为皮层摄取阳性或阴性。
  • FDG-PET视觉判读分为AD型或非AD型。
  • 神经病理诊断采用研究标准,比较中-高ADNC。

临床怎么用

  • 对于年轻起病的认知障碍患者,PIB-PET在检测AD病理方面敏感性优于FDG-PET。
  • 当PIB与FDG判读一致时,可高度提示AD病理存在或排除。
  • 当PIB与FDG判读不一致时,应警惕AD与非AD混合病理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The purpose of this study was to compare the diagnostic accuracy of antemortem 11 C-Pittsburgh compound B (PIB) and 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) versus autopsy diagnosis in a heterogenous sample of patients. METHODS: One hundred one participants underwent PIB and FDG PET during life and neuropathological assessment. PET scans were visually interpreted by 3 raters blinded to clinical information. PIB PET was rated as positive or negative for cortical retention, whereas FDG scans were read as showing an Alzheimer disease (AD) or non-AD pattern. Neuropathological diagnoses were assigned using research criteria. Majority visual reads were compared to intermediate-high AD neuropathological change (ADNC). RESULTS: One hundred one participants were included (mean age = 67.2 years, 41 females, Mini-Mental State Examination = 21.9, PET-to-autopsy interval = 4.4 years). At autopsy, 32 patients showed primary AD, 56 showed non-AD neuropathology (primarily frontotemporal lobar degeneration [FTLD]), and 13 showed mixed AD/FTLD pathology. PIB showed higher sensitivity than FDG for detecting intermediate-high ADNC (96%, 95% confidence interval [CI] = 89-100% vs 80%, 95% CI = 68-92%, p = 0.02), but equivalent specificity (86%, 95% CI = 76-95% vs 84%, 95% CI = 74-93%, p = 0.80). In patients with congruent PIB and FDG reads (77/101), combined sensitivity was 97% (95% CI = 92-100%) and specificity was 98% (95% CI = 93-100%). Nine of 24 patients with incongruent reads were found to have co-occurrence of AD and non-AD pathologies. INTERPRETATION: In our sample enriched for younger onset cognitive impairment, PIB-PET had higher sensitivity than FDG-PET for intermediate-high ADNC, with similar specificity. When both modalities are congruent, sensitivity and specificity approach 100%, whereas mixed pathology should be considered when PIB and FDG are incongruent. ANN NEUROL 2021;89:389-401.

来源:Ann Neurol,查看原文。版权归原作者所有。

引用

  1. Lesman-Segev OH, La Joie R, Iaccarino L, et al. Diagnostic Accuracy of Amyloid versus 18 F-Fluorodeoxyglucose Positron Emission Tomography in Autopsy-Confirmed Dementia. Ann Neurol. 2020. PMID: 33219525. doi:10.1002/ana.25968

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。