成人癫痫持续状态中计算游离丙戊酸水平的准确性
该研究在瑞士学术医疗中心纳入2005至2018年成人癫痫持续状态患者,比较由总丙戊酸和血清白蛋白计算出的游离丙戊酸(fVPA)与实际测量值的一致性。结果显示计算值与测量值在39.8%的测量中有效药物水平分类不一致,计算值高估测量值占30.4%,提示该方程不准确,应基于实测fVPA进行药物监测。
要点
- 计算fVPA与实测fVPA在39.8%的测量中有效药物水平分类不一致。
- 计算fVPA高估实测fVPA的比例为30.4%。
- 总丙戊酸和血清白蛋白独立影响计算fVPA的准确性。
核心结论
- 在成人癫痫持续状态患者中,使用所提方程计算fVPA不准确,应基于实测fVPA进行药物监测。
研究设计与样本
- 回顾性纳入2005至2018年瑞士学术医疗中心成人癫痫持续状态患者,共104例的506次同时测量总丙戊酸、游离丙戊酸和血清白蛋白。
主要发现
- 计算fVPA与实测fVPA的中位偏差为-0.8 mg/L(四分位距-3.2至2.5),其中336次测量偏差>1 mg/L。
- 实测与计算fVPA呈线性关联,回归系数1.1(95%置信区间0.9-1.2,p<0.0001)。
- 无论血清白蛋白水平如何,39.8%的测量中计算与实测fVPA的有效药物水平分类不一致,计算值高估实测值占30.4%。
- 多变量模型中总丙戊酸和血清白蛋白独立影响计算fVPA的准确性。
关键数值与推荐
- fVPA分类:低于治疗水平、治疗水平(5-10 mg/L)或高于治疗水平。
- 一致性定义为实测与计算fVPA落入同一分类的比例。
临床怎么用
- 成人癫痫持续状态患者不应依赖计算fVPA评估疗效,应直接测量游离丙戊酸水平进行药物监测。
局限性
- 研究为单中心回顾性设计,样本来自瑞士学术医疗中心,外推性需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To test the accuracy of an equation in adult patients with status epilepticus that calculates the free concentration of serum valproic acid (fVPA) from the total concentration of serum valproic acid (tVPA) and serum albumin. METHODS: All adult patients with status epilepticus who were treated at a Swiss academic medical center between 2005 and 2018 with concurrent measurements of tVPA, fVPA, and serum albumin were included. fVPA was categorized as subtherapeutic, therapeutic (5-10 mg/L), or supratherapeutic. Agreement was defined as the proportion of measured and calculated fVPA falling within the same category. RESULTS: Of 676 patients with status epilepticus, 104 had 506 measurements, with a median of 3 (interquartile range [IQR] 1.5-6.5) per patient. The median tVPA was 43.5 mg/L (27.4-63.6), with measured fVPA 9.1 mg/L (4.5-14.7) and calculated fVPA 10.1 mg/L (7.0-13.0), respectively. The median deviation of calculated from measured fVPA was -0.8 mg/L (-3.2 to 2.5) with 336 measurements >1 mg/L. While the association between measured and calculated fVPA was linear (regression coefficient 1.1, 95% confidence interval 0.9-1.2, p < 0.0001), the agreement on effective drug levels did not match in 39.8% of measurements regardless of serum albumin levels, with calculated fVPA overestimating measured fVPA in 30.4%. tVPA and serum albumin independently influenced the accuracy of the calculated fVPA in the multivariable model. CONCLUSIONS: Calculated fVPA is inaccurate when using the proposed equation in adult patients with status epilepticus, calling for drug monitoring based on measured fVPA in this context.
引用
- Fisch U, Baumann SM, Semmlack S, et al. Accuracy of Calculated Free Valproate Levels in Adult Patients With Status Epilepticus. Neurology. 2020. PMID: 33055270. doi:10.1212/WNL.0000000000011000
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。