文献速递癫痫

颅内脑电快涟漪与癫痫手术预后相关

Association of fast ripples on intracranial EEG and outcomes after epilepsy surgery.
PubMed 文献 · Neurology · 2020-08-04

研究分析43例癫痫患者的夜间立体脑电图,假设快涟漪(FR)切除比例、最大FR率和FR分布可预测术后发作结局。结果显示,全夜记录下FR事件切除比例预测准确率最高(81%,95%CI 67%-92%),无FR率>6/min的通道及无或未完全切除1个优势FR区域与不良结局相关。

要点

  • 全夜记录FR切除比例预测术后结局准确率81%。
  • 无FR率>6/min通道或未完全切除优势FR区提示不良结局。
  • FR是癫痫手术预后的准确标志物,需全夜记录。

核心结论

  • 全夜记录下快涟漪(FR)能准确预测癫痫手术结局。
  • 无高FR率通道或未完全切除优势FR区是不良预后因素。

研究设计与样本

  • 分析43例患者夜间立体脑电图记录。
  • 自动检测FR并人工编辑伪迹,另视觉分析5分钟慢波睡眠期。

主要发现

  • FR事件切除比例全夜记录预测准确率81%(95%CI 67%-92%)。
  • 视觉5分钟方法预测准确率72%(95%CI 56%-85%)。
  • 无FR率>6/min通道与不良结局相关(p=0.001)。
  • 无或未完全切除1个优势FR区域与不良结局相关(p<0.001)。

关键数值与推荐

  • 切除≥50%总FR事件或FR通道作为预测指标。
  • FR率>6/min为高FR率通道阈值。

临床怎么用

  • 利用全夜立体脑电图FR切除比例评估癫痫手术预后。
  • 关注高FR率通道和优势FR区域的完全切除。

局限性

  • 样本量43例,证据等级为Class II。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To examine whether fast ripples (FRs) are an accurate marker of the epileptogenic zone, we analyzed overnight stereo-EEG recordings from 43 patients and hypothesized that FR resection ratio, maximal FR rate, and FR distribution predict postsurgical seizure outcome. METHODS: We detected FRs automatically from an overnight recording edited for artifacts and visually from a 5-minute period of slow-wave sleep. We examined primarily the accuracy of removing ≥50% of total FR events or of channels with FRs to predict postsurgical seizure outcome (Engel class I = good, classes II-IV = poor) according to the whole-night and 5-minute analysis approaches. Secondarily, we examined the association of low overall FR rates or absence or incomplete resection of 1 dominant FR area with poor outcome. RESULTS: The accuracy of outcome prediction was highest (81%, 95% confidence interval [CI] 67%-92%) with the use of the FR event resection ratio and whole-night recording (vs 72%, 95% CI 56%-85%, for the visual 5-minute approach). Absence of channels with FR rates >6/min (p = 0.001) and absence or incomplete resection of 1 dominant FR area (p < 0.001) were associated with poor outcome. CONCLUSIONS: FRs are accurate in predicting epilepsy surgery outcome at the individual level when overnight recordings are used. Absence of channels with high FR rates or absence of 1 dominant FR area is a poor prognostic factor that may reflect suboptimal spatial sampling of the epileptogenic zone or multifocality, rather than an inherently low sensitivity of FRs. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that FRs are accurate in predicting epilepsy surgery outcome.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Nevalainen P, von Ellenrieder N, Klimeš P, et al. Association of fast ripples on intracranial EEG and outcomes after epilepsy surgery. Neurology. 2020. PMID: 32753439. doi:10.1212/WNL.0000000000010468

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。