神经超声诊断慢性炎性神经病:多中心验证研究
该前瞻性多中心研究纳入100例临床疑似慢性炎性神经病(CIN)患者,验证一套短程神经超声方案(正中神经前臂、上臂及C5神经根)的诊断准确性,并比较神经超声与神经传导研究(NCS)检测治疗反应患者的价值。结果显示,超声方案敏感性87.4%、特异性67.3%,加用超声后CIN诊断数从33例增至44例。
要点
- 短程神经超声方案诊断CIN敏感性87.4%、特异性67.3%。
- 加用神经超声后CIN诊断数从33例增至44例,可多检出至多25%治疗反应患者。
- 神经超声可作为NCS的补充工具提高CIN诊断率。
核心结论
- 短程神经超声方案对慢性炎性神经病(CIN)具有较高诊断准确性。
- 神经超声可较单独NCS多检出至多25%的治疗反应患者。
研究设计与样本
- 前瞻性多中心研究,纳入3个中心连续100例临床疑似CIN患者。
- 研究方案包括神经系统检查、实验室检查、NCS和神经超声。
- 验证短程超声方案(正中神经前臂、上臂及C5神经根),以欧洲神经病学学会联盟/周围神经学会CIDP/MMN标准为参考标准。
- 另采用基于临床、NCS、超声及治疗反应的替代参考标准评估超声的附加价值。
主要发现
- 按参考标准,超声方案诊断CIN敏感性87.4%、特异性67.3%。
- 按替代参考标准,超声方案敏感性84.6%、特异性72.8%,NCS敏感性76.1%、特异性93.4%。
- 加用神经超声后确立44例CIN诊断,而单独NCS为33例。
临床怎么用
- 对临床疑似CIN患者,可在NCS基础上加用短程神经超声以提高诊断检出。
- 短程超声方案可评估正中神经前臂、上臂及C5神经根。
局限性
- 证据等级为Class IV。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To validate the diagnostic accuracy of a previously described short sonographic protocol to identify chronic inflammatory neuropathy (CIN), including chronic inflammatory demyelinating polyneuropathy (CIDP), Lewis Sumner syndrome, and multifocal motor neuropathy (MMN), and to determine the added value of nerve ultrasound to detect treatment-responsive patients compared to nerve conduction studies (NCS) in a prospective multicenter study. METHODS: We included 100 consecutive patients clinically suspected of CIN in 3 centers. The study protocol consisted of neurologic examination, laboratory tests, NCS, and nerve ultrasound. We validated a short sonographic protocol (median nerve at forearm, upper arm, and C5 nerve root) and determined its diagnostic accuracy using the European Federation of Neurological Societies/Peripheral Nerve Society criteria of CIDP/MMN (reference standard). In addition, to determine the added value of nerve ultrasound in detecting treatment-responsive patients, we used previously published diagnostic criteria based on clinical, NCS, and sonographic findings and treatment response (alternative reference standard). RESULTS: Sensitivity and specificity of the sonographic protocol for CIN according to the reference standard were 87.4% and 67.3%, respectively. Sensitivity and specificity of this protocol according to the alternative reference standard were 84.6% and 72.8%, respectively, and of NCS 76.1% and 93.4%. With addition of nerve ultrasound, 44 diagnoses of CIN were established compared to 33 diagnoses with NCS alone. CONCLUSIONS: A short sonographic protocol shows high diagnostic accuracy for detecting CIN. Nerve ultrasound is able to detect up to 25% more patients who respond to treatment. CLASSIFICATION OF EVIDENCE: This multicenter study provides Class IV evidence that nerve ultrasound improves diagnosis of CIN.
引用
- Herraets IJT, Goedee HS, Telleman JA, et al. Nerve ultrasound for diagnosing chronic inflammatory neuropathy: A multicenter validation study. Neurology. 2020. PMID: 32675082. doi:10.1212/WNL.0000000000010369
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。