文献速递脑血管病认知障碍与痴呆

3T磁共振成像检测皮质微梗死:区分脑淀粉样血管病与栓塞

Cortical Microinfarcts Detected by 3-Tesla Magnetic Resonance Imaging: Differentiation Between Cerebral Amyloid Angiopathy and Embolism.
PubMed 文献 · Stroke · 2019-12-23

本研究回顾性纳入70例在3D双反转恢复成像上至少有一个<10 mm皮质梗死灶的患者,其中43例有栓塞性卒中史(Emboli-G),27例为脑淀粉样血管病(CAA)组,比较两组皮质微梗死(CMI)的大小、数量、位置和分布,并设计放射学评分以区分CAA与微栓塞所致CMI。

要点

  • CAA组病灶多<5 mm且局限于皮质,Emboli-G组皮质病灶数量更多。
  • CAA组病灶好发于枕叶,Emboli-G组好发于额叶或顶叶。
  • 放射学评分≥3分可较强预测微栓塞或CAA。

核心结论

  • 3T磁共振成像上CMI的特征可能区分CAA所致与微栓塞所致CMI。

研究设计与样本

  • 回顾性研究纳入70例在3D双反转恢复成像上至少有一个<10 mm皮质梗死灶的患者,其中43例有栓塞性卒中史(Emboli-G),27例为CAA组。

主要发现

  • CAA组<5 mm且局限于皮质的病灶显著更多(P<0.01)。
  • Emboli-G组皮质病灶数量显著高于CAA组(4 versus 2;P<0.01)。
  • CAA组病灶不成比例地位于枕叶(P<0.01),Emboli-G组位于额叶或顶叶(P=0.04)。

关键数值与推荐

  • 放射学评分≥3分预测微栓塞的敏感性63%、特异性92%,预测CAA的敏感性63%、特异性91%。
  • 微栓塞和CAA的受试者工作特征曲线下面积分别为0.85和0.87。

临床怎么用

  • 对于3T磁共振成像上发现皮质微梗死的患者,可结合病灶大小、数量、位置分布及放射学评分辅助鉴别CAA与微栓塞。

局限性

  • 本研究为回顾性研究,样本量有限,放射学评分需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background and Purpose- Cortical microinfarcts (CMIs) are small ischemic lesions found in cerebral amyloid angiopathy (CAA) and embolic stroke. This study aimed to differentiate CMIs caused by CAA from those caused by microembolisms, using 3-Tesla magnetic resonance imaging. Methods- We retrospectively investigated 70 patients with at least 1 cortical infarct <10 mm on 3-dimensional double inversion recovery imaging. Of the 70 patients, 43 had an embolic stroke history (Emboli-G) while 27 had CAA-group. We compared the size, number, location, and distribution of CMIs between groups and designed a radiological score for differentiation based on the comparisons. Results- CAA-group showed significantly more lesions <5 mm, which were restricted to the cortex (P<0.01). Cortical lesion number was significantly higher in Emboli-G than in CAA-group (4 versus 2; P<0.01). Lesions in CAA-group and Emboli-G were disproportionately located in the occipital lobe (P<0.01) and frontal or parietal lobe (P=0.04), respectively. In radiological scoring, ≥3 points strongly predicted microembolism (sensitivity, 63%; specificity, 92%) or CAA (sensitivity, 63%; specificity, 91%). The areas under the receiver operating characteristic curve were 0.85 and 0.87 for microembolism and CAA, respectively. Conclusions- Characteristics of CMIs on 3T-magnetic resonance imaging may differentiate CMIs due to CAA from those due to microembolisms.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Ishikawa H, Ii Y, Shindo A, et al. Cortical Microinfarcts Detected by 3-Tesla Magnetic Resonance Imaging: Differentiation Between Cerebral Amyloid Angiopathy and Embolism. Stroke. 2019. PMID: 31865894. doi:10.1161/STROKEAHA.119.028202

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。