文献速递脑血管病

基线肌钙蛋白与卒中后急性心肌梗死的关联

Association of Baseline Cardiac Troponin With Acute Myocardial Infarction in Stroke Patients Presenting Within 4.5 Hours.
PubMed 文献 · Stroke · 2019-12-04

该研究回顾性分析1072例在最后正常时间4.5小时内就诊的急性缺血性卒中或短暂性脑缺血发作患者,其中525例在72小时内检测了基线心肌肌钙蛋白I。结果显示,4.5小时后检测的基线肌钙蛋白I对急性心肌梗死的诊断准确性高于4.5小时内检测。

要点

  • 4.5小时内检测基线肌钙蛋白I对急性心肌梗死敏感性仅25%。
  • 4.5至72小时检测基线肌钙蛋白I敏感性达90.9%。
  • 基线肌钙蛋白检测时间与急性心肌梗死独立相关。

核心结论

  • 在最后正常时间4.5小时后检测基线心肌肌钙蛋白I对急性心肌梗死的诊断准确性高于4.5小时内检测。

研究设计与样本

  • 回顾性分析1072例在最后正常时间4.5小时内就诊的急性缺血性卒中或短暂性脑缺血发作患者,其中525例在72小时内检测了基线心肌肌钙蛋白I。

主要发现

  • 最后正常时间至基线心肌肌钙蛋白I检测的中位时间为3.8小时。
  • 4.5小时内检测基线心肌肌钙蛋白I较4.5至72小时检测更常为正常值(61.7% vs 38.3%;P=0.001)。
  • 校正混杂因素后,基线心肌肌钙蛋白I检测时间与急性心肌梗死独立相关(比值比1.04 [95%CI 1.02-1.07] P=0.001)。

关键数值与推荐

  • 4.5小时内检测基线心肌肌钙蛋白I对急性心肌梗死的敏感性为25%,特异性为83.7%。
  • 4.5至72小时检测基线心肌肌钙蛋白I对急性心肌梗死的敏感性为90.9%,特异性为74.8%。

临床怎么用

  • 对于在最后正常时间4.5小时内就诊的卒中患者,4.5小时后检测基线肌钙蛋白I可能提高急性心肌梗死的诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background and Purpose- American Heart Association guidelines recommend obtaining baseline troponin in all patients with acute ischemic stroke. Yet, there is a paucity of data on the prevalence of baseline troponin elevation and specifically its diagnostic yield for acute myocardial infarction (AMI) in patients presenting within the time window for thrombolysis. Methods- We retrospectively analyzed 1072 consecutive patients admitted for acute ischemic stroke or transient ischemic attack, who presented within 4.5 hours of last known well (LKW). Patients who had baseline cardiac troponin I (bcTnI) obtained within 72 hours from LKW (n=525) were included in the study. Multivariable logistic regression was conducted to determine factors independently related to an elevated bcTnI (>0.04 ng/mL). We calculated the area under receiver operator curves, sensitivity, and specificity, to determine the diagnostic accuracy of (i) the bcTnI for AMI stratified by the time to assessment and (ii) the best time cutoff for obtaining bcTnI. Results- Among included subjects, the median time from LKW to the bcTnI was 3.8 hours and 113 (21.5%) subjects had an elevated bcTnI. Assessment of bcTnI within 4.5 hours from LKW was significantly more often associated with normal values as compared to assessment between 4.5 and 72 hours (61.7% versus 38.3%; P=0.001). Fifteen (2.9%) patients were diagnosed with AMI. After adjustment for pertinent confounders, time to bcTnI assessment was independently associated with AMI (odds ratio, 1.04 [95% CI, 1.02-1.07] P=0.001). When stratified by time, bcTnI assessed within 4.5 hours had a sensitivity of 25% and specificity of 83.7% for AMI, whereas bcTnI assessment between 4.5 and 72 hours was associated with a sensitivity of 90.9% and specificity of 74.8%. Conclusions- Assessment of bcTnI after 4.5 hours from LKW was associated with greater diagnostic accuracy than testing within 4.5 hours. This information may inform routine clinical practice.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Sun Y, Miller MM, Yaghi S, et al. Association of Baseline Cardiac Troponin With Acute Myocardial Infarction in Stroke Patients Presenting Within 4.5 Hours. Stroke. 2019. PMID: 31795903. doi:10.1161/STROKEAHA.119.027878

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。