文献速递脑血管病

卒中风险分析系统在卒中及短暂性脑缺血发作中高检出率的心房颤动检测

Stroke Risk Analysis, a System With a High Detection Rate of Atrial Fibrillation in Stroke and Transient Ischemic Attack.
PubMed 文献 · Stroke · 2019-12-17

这项前瞻性多中心观察性研究纳入524例无房颤史的急性缺血性卒中或短暂性脑缺血发作患者,比较Holter连续心电监测联合卒中风险分析(hSRA)与标准连续心电监测对阵发性房颤的检出率。结果显示hSRA检出房颤17.1%(经盲法心内科医生确认9.7%),显著高于标准监测的4.3%(P<0.0001);hSRA首个周期内R_AF模式的阴性预测值达96%。

要点

  • hSRA技术显著提高急性缺血性卒中患者阵发性房颤检出率。
  • hSRA检出房颤17.1%,标准连续心电监测仅4.3%(P<0.0001)。
  • 首个监测周期R_AF模式阴性预测值96%,有助于排除房颤。

核心结论

  • 自动化SRA技术相比标准连续心电监测大幅提高急性缺血性卒中患者的阵发性房颤检出率。

研究设计与样本

  • 前瞻性多中心观察性分析临床研究,采用患者自身对照,纳入524例连续入卒中单元的急性缺血性卒中或短暂性脑缺血发作患者。
  • 患者无房颤病史且入院时无房颤,同时接受连续心电监测和hSRA监测最长7天,最终462例纳入分析。
  • hSRA结果对研究者设盲,除非SRA检出阵发性房颤。

主要发现

  • 462例患者中hSRA可用监测时间中位66小时,hSRA检出房颤79例(17.1%),经独立盲法心内科医生复核确认45例(9.7%)。
  • 标准连续心电监测检出房颤21例(4.3%),与hSRA检出率比较P<0.0001。
  • hSRA检出R_AF模式92例,其中35例在卒中单元期间出现房颤发作。
  • hSRA首个周期内R_AF模式的预测值为:敏感度71%、特异度86%、阳性预测值38%、阴性预测值96%。

关键数值与推荐

  • hSRA检出房颤79例(17.1%),确认房颤45例(9.7%)。
  • 标准连续心电监测检出房颤21例(4.3%),与hSRA比较P<0.0001。
  • 首个周期R_AF模式:敏感度71%、特异度86%、阳性预测值38%、阴性预测值96%。

临床怎么用

  • 在急性缺血性卒中或短暂性脑缺血发作患者中,可考虑使用hSRA提高阵发性房颤的检出。
  • hSRA首个周期R_AF模式阴性预测值高,有助于早期排除房颤。

局限性

  • hSRA首个周期R_AF模式的预测价值需进一步研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background and Purpose- Stroke Risk Analysis (SRA) comprises an algorithm for automated analysis of ECG monitoring, enabling the detection of paroxysmal atrial fibrillation (pxAF) and identifying patterns indicating a high risk of atrial fibrillation (R_AF). We compared Holter-enabled continuous ECG monitoring in combination with SRA (hSRA) with standard continuous ECG monitoring for pxAF detection in patients with acute ischemic stroke. Also, we sought to identify whether the detection of R_AF patterns during the first cycle (first 2 hours) of hSRA recording was associated with the detection of pxAF during the Stroke Unit stay. Methods- We enrolled 524 consecutive patients admitted in the Stroke Unit with acute ischemic stroke or transient ischemic attack with neither history of AF nor AF at admission into a prospective multicentric observational analytic clinical study with intrapatient comparison, who received both continuous ECG monitoring as well as hSRA up to 7 days. Investigators were blinded to hSRA results unless pxAF was detected on SRA. Results- Of the 524 consecutive acute stroke patients (median age, 70.0 years; 60% male; acute ischemic stroke 93%, transient ischemic attack 7%), 462 were eligible and included in the study. Among 462 patients with hSRA available for 66 hours, AF was documented by hSRA in 79 patients (17.1%). From this group, 45 AF cases (9.7%) were confirmed after review by an independent and blinded cardiologist. continuous ECG monitoring detected 21 AF cases (4.3%; P<0.0001). hSRA detected R_AF patterns in 92 patients. 35 out of the 92 R_AF patients showed an episode of AF during the Stroke Unit stay. Predictive values of R_AF patterns within the first cycle of hSRA were: sensitivity 71%, specificity 86%, positive predictive value 38%, and negative predictive value 96%. Conclusions- Automated analysis using SRA technology strongly improves pxAF detection in acute ischemic stroke patients compared with continuous ECG monitoring. The predictive value of a R_AF pattern, as detected by hSRA during the first few hours after admission, deserves further investigation.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Gomis M, Dávalos A, Purroy F, et al. Stroke Risk Analysis, a System With a High Detection Rate of Atrial Fibrillation in Stroke and Transient Ischemic Attack. Stroke. 2019. PMID: 31842722. doi:10.1161/STROKEAHA.119.026354