文献速递脑血管病

CT血管造影自动检测大血管闭塞的快速方法

Fast Automatic Detection of Large Vessel Occlusions on CT Angiography.
PubMed 文献 · Stroke · 2019-11-04

本研究基于多中心926例患者的CTA数据,评估全自动软件检测前循环大血管闭塞(LVO)的诊断性能,以2名神经放射科医师共识为参考标准。结果显示,检测LVO的敏感度97%、特异度74%,纳入M2闭塞后分别为95%和79%。

要点

  • 自动软件检测前循环LVO敏感度97%、特异度74%。
  • 纳入M2闭塞后敏感度95%、特异度79%。
  • 按部位敏感度:M2 90%、M1 97%、颅内ICA 97%。

核心结论

  • 全自动检测工具可快速可靠地检测颅内前循环LVO及近端M2闭塞。

研究设计与样本

  • 回顾性队列研究,汇总2项卒中试验、单中心取栓候选者与正常者、单区域医院code stroke患者共926例CTA。

主要发现

  • 检测LVO敏感度97%、特异度74%;纳入M2闭塞后敏感度95%、特异度79%。
  • 按闭塞部位敏感度:M2-MCA 90%、M1-MCA 97%、颅内ICA 97%,对应AUC分别为0.874、0.962、0.997。

关键数值与推荐

  • 以2名神经放射科医师共识读片为参考标准。
  • 采用ROC分析评估算法检测前循环LVO、前循环LVO+近端M2闭塞及单个节段闭塞的诊断性能。

临床怎么用

  • 该工具可能促进卒中患者院内及院间工作流程和急诊影像分诊。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background and Purpose- Accurate and rapid detection of anterior circulation large vessel occlusion (LVO) is of paramount importance in patients with acute stroke due to the potentially rapid infarction of at-risk tissue and the limited therapeutic window for endovascular clot retrieval. Hence, the optimal threshold of a new, fully automated software-based approach for LVO detection was determined, and its diagnostic performance evaluated in a large cohort study. Methods- For this retrospective study, data were pooled from: 2 stroke trials, DEFUSE 2 (n=62; 07/08-09/11) and DEFUSE 3 (n=213; 05/17-05/18); a cohort of endovascular clot retrieval candidates (n=82; August 2, 2014-August 30, 2015) and normals (n=111; June 6, 2017-January 28, 2019) from a single quaternary center; and code stroke patients (n=501; January 1, 2017-December 31, 2018) from a single regional hospital. All CTAs were assessed by the automated algorithm. Consensus reads by 2 neuroradiologists served as the reference standard. ROC analysis was used to assess diagnostic performance of the algorithm for detection of (1) anterior circulation LVOs involving the intracranial internal carotid artery or M1 segment middle cerebral artery (M1-MCA); (2) anterior circulation LVOs and proximal M2 segment MCA (M2-MCA) occlusions; and (3) individual segment occlusions. Results- CTAs from 926 patients (median age 70 years, interquartile range: 58-80; 422 females) were analyzed. Three hundred ninety-five patients had an anterior circulation LVO or M2-MCA occlusion (National Institutes of Health Stroke Scale 14 [median], interquartile range: 9-19). Sensitivity and specificity were 97% and 74%, respectively, for LVO detection, and 95% and 79%, respectively, when M2 occlusions were included. On analysis by occlusion site, sensitivities were 90% (M2-MCA), 97% (M1-MCA), and 97% (intracranial internal carotid artery) with corresponding area-under-the-ROC-curves of 0.874 (M2), 0.962 (M1), and 0.997 (intracranial internal carotid artery). Conclusions- Intracranial anterior circulation LVOs and proximal M2 occlusions can be rapidly and reliably detected by an automated detection tool, which may facilitate intra- and inter-instutional workflows and emergent imaging triage in the care of patients with stroke.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Amukotuwa SA, Straka M, Dehkharghani S, et al. Fast Automatic Detection of Large Vessel Occlusions on CT Angiography. Stroke. 2019. PMID: 31679501. doi:10.1161/STROKEAHA.119.027076

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。