头颈部动脉夹层高分辨磁共振成像特征与卒中的关联
本研究纳入118例头颈部动脉夹层患者的145条受累血管,比较卒中组与非卒中组的高分辨磁共振成像特征。多因素分析显示,不规则表面和管腔内血栓与急性缺血性卒中独立相关,其比值比分别为4.29和7.48。高分辨磁共振成像可能有助于早期个体化预测头颈部动脉夹层患者的缺血性卒中风险。
要点
- 不规则表面和管腔内血栓是头颈部动脉夹层患者发生卒中的独立相关影像特征。
- 卒中组中管腔内血栓和不规则表面比例显著高于非卒中组。
- 高分辨磁共振成像或可用于头颈部动脉夹层早期卒中风险的个体化预测。
核心结论
- 不规则表面和管腔内血栓与头颈部动脉夹层患者卒中发生相关。
- 高分辨磁共振成像有助于揭示头颈部动脉夹层缺血性卒中的发病机制。
研究设计与样本
- 纳入头颈部动脉夹层患者并分为卒中组和非卒中组。
- 共分析来自118例患者的145条受累血管。
- 采用多因素logistic回归分析影像特征与缺血性卒中的关联。
主要发现
- 卒中组前循环比例54.4% vs 36.4%(P=0.030)。
- 卒中组壁内血肿比例96.2% vs 84.8%(P=0.017)。
- 卒中组不规则表面比例74.7% vs 37.9%(P<0.001)。
- 卒中组管腔内血栓比例44.3% vs 4.5%(P<0.001)。
- 卒中组重度狭窄(>70%)比例54.4% vs 31.8%(P=0.008)。
关键数值与推荐
- 不规则表面与急性缺血性卒中独立相关,OR=4.29(95%CI 1.61-11.46,P=0.004)。
- 管腔内血栓与急性缺血性卒中独立相关,OR=7.48(95%CI 1.64-34.07,P=0.009)。
临床怎么用
- 对头颈部动脉夹层患者应关注高分辨磁共振成像上的不规则表面和管腔内血栓。
- 上述影像特征可能辅助早期识别卒中高风险患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background and Purpose- We aimed to systematically investigate the characteristics of cervicocranial artery dissection (CCAD) on high-resolution magnetic resonance imaging that are associated with acute ischemic stroke. Methods- Patients with CCAD were recruited and divided into stroke and nonstroke groups. The lesion location, the presence of a double lumen, intimal flap, intramural hematoma, pseudoaneurysm, irregular surface, intraluminal thrombus, and other quantitative parameters of each dissected segment were reviewed. Multiple logistic regression was used to examine the association between imaging features of CCAD and ischemic stroke. Results- A total of 145 affected vessels from 118 patients with CCAD were analyzed. Anterior circulation, intramural hematoma, irregular surface, intraluminal thrombus, and severe stenosis (>70%) on high-resolution magnetic resonance imaging were more prevalent in CCAD patient with stroke (54.4% versus 36.4%; P=0.030, 96.2% versus 84.8%; P=0.017, 74.7% versus 37.9%; P<0.001, 44.3% versus 4.5%; P<0.001, and 54.4% versus 31.8%; P=0.008, respectively). In multivariable logistic regression analysis, the presence of irregular surface and intraluminal thrombus on imaging were independently associated with acute ischemic stroke in CCAD with odds ratios of 4.29 (95% CI, 1.61-11.46, P=0.004) and 7.48 (95% CI, 1.64-34.07, P=0.009). Conclusions- The current findings supported that the presence of irregular surface and intraluminal thrombus were related to stroke occurrence in patients with CCAD. High-resolution magnetic resonance imaging might give insights into pathogenesis of ischemic stroke in CCAD. It may be useful for individual prediction of ischemic stroke early in CCAD.
引用
- Wu Y, Wu F, Liu Y, et al. High-Resolution Magnetic Resonance Imaging of Cervicocranial Artery Dissection: Imaging Features Associated With Stroke. Stroke. 2019. PMID: 31514693. doi:10.1161/STROKEAHA.119.026362
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。