急性缺血性卒中取栓术中血压与功能结局的系统综述
该系统综述纳入9项研究共1037例患者,评估机械取栓围术期血压对功能结局的影响。5项研究提示平均动脉压下降与3个月不良功能结局相关,4项研究未显示关联,其中3项采用严格的围术期收缩压目标(140-180 mm Hg)。
要点
- 取栓术中平均动脉压下降可能预测3个月不良功能结局。
- 严格达到收缩压140-180 mm Hg目标时,血压与功能结局无关联。
- 结论需随机对照试验进一步验证。
核心结论
- 取栓术中血压下降可能与更差的功能结局相关。
- 当达到严格的收缩压目标时,未观察到血压与功能结局的关联。
研究设计与样本
- 系统综述纳入2012年1月1日后发表的9项研究,共1037例患者。
- 因血压监测和参数异质性未进行荟萃分析。
主要发现
- 4项研究未显示取栓术中血压与功能结局的关联,其中3项采用严格的围术期收缩压目标(140-180 mm Hg)。
关键数值与推荐
- 平均动脉压是描述取栓术中血压变异最常报告的参数。
- 收缩压是定义围术期血压目标的主要参数。
临床怎么用
- 取栓术中应关注平均动脉压下降,避免较基线下降>40%或>10%。
- 维持收缩压在140-180 mm Hg目标范围内可能与功能结局无显著关联。
局限性
- 研究间血压监测和参数异质性大,无法进行荟萃分析。
- 结论需随机对照试验进一步评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background and Purpose- Optimal blood pressure (BP) targets during mechanical thrombectomy (MT) for acute ischemic stroke (AIS) are unknown, and randomized controlled trials addressing this issue are lacking. We aimed to perform a systematic review of studies evaluating the influence of periprocedural BP on functional outcome after MT. Methods- Studies assessing periprocedural BP effect on functional outcome published after January 1st, 2012 were included in the systematic review. The PRISMA checklist and flow diagram were followed for the design and reporting of this work. Results- Nine studies were included, for a total of 1037 patients. The heterogeneity in findings with respect to BP monitoring and studied parameters precluded a meta-analysis. Mean arterial pressure was the most frequently reported parameter to describe BP variability during MT, and systolic BP was the main parameter used to define periprocedural BP targets. Five studies suggested an association between 3 types of BP drops as predictors of poor functional outcome at 3 months: >40% drop in mean arterial pressure compared with baseline (odds ratio=2.8; [1.09-7.19]; P=0.032), lowest mean arterial pressure before recanalization (odds ratio=1.28; [1.01-1.62] per 10 mm Hg drop below 100 mm Hg; P=0.04), and MAP drops (odds ratio=4.38; [1.53-12.6] for drops >10%). Four studies did not show an association between BP during MT and functional outcome, including 3 studies with strict periprocedural systolic BP targets (within a 140-180 mm Hg). Conclusions- BP drops during MT may be associated with a worse functional outcome. When strict systolic BP targets are achieved, no association between BP and functional outcome was also noted. Both conclusions require further evaluation in randomized studies.
引用
- Maïer B, Fahed R, Khoury N, et al. Association of Blood Pressure During Thrombectomy for Acute Ischemic Stroke With Functional Outcome: A Systematic Review. Stroke. 2019. PMID: 31462188. doi:10.1161/STROKEAHA.119.024915
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。