患者特异性主动脉弓模型中影响栓塞物轨迹的血流动力学研究
结果显示栓塞物轨迹并非仅取决于大小,较高密度血栓更倾向沿脑血管走行(P<0.05),同时释放更多血栓会增加至少一个血栓通过主动脉弓分支血管的概率。
要点
- 栓塞物轨迹不单独由大小决定,较长血栓也可通过颈总动脉。
- 较高密度血栓更倾向于沿脑血管走行(P<0.05)。
- 同时释放更多血栓会增加至少一个血栓进入主动脉弓分支血管的概率。
核心结论
- 栓塞物通过主动脉弓分支血管的轨迹并非仅取决于栓塞物大小。
- 栓塞物倾向于按出口流速比例走行,多个脱落栓子导致卒中的机会更大。
研究设计与样本
- 基于一名77岁房颤伴右侧M1远端闭塞男性的医学影像数据集制作患者特异性主动脉弓模型。
- 另用5-20 NIH单位凝血酶制作270个不同血栓,并分组同时释放多个血栓,共释放504个栓塞物。
主要发现
- 长度≤10 mm的栓塞物类似物是通过颈总动脉最常见的几何形态(44%)。
- 较高密度血栓增加沿脑血管走行的倾向(P<0.05)。
- 每次测试释放更多血栓增加至少一个血栓通过主动脉弓分支血管的概率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background and Purpose- Cardiogenic emboli account for 15% to 20% of acute ischemic stroke cases worldwide. However, the chance of such emboli, of varying sizes, causing a stroke under various flow types has not been evaluated. Methods- A patient-specific aortic arch model was fabricated from a medical image dataset of a 77-year-old male case, with atrial fibrillation and distal occlusion of the right M1 vessel. One hundred and eighty mammalian embolus analogs (EAs) were released one by one into the model under normal and atrial fibrillation flow conditions. A further 270 clots were fabricated using varying levels of thrombin (5-20 National Institutes of Health units thrombin). The effect of releasing several clots simultaneously was also examined by grouping EAs into 18 multiples of 5, 4, 3, and 2 clots, resulting in 504 EAs released. Results- EAs with a length of ≤10 mm were the most common geometry to travel through the common carotid arteries (44%); however, longer clots also traveled through these narrow vessels. Twenty two percent of EAs ranged from 10-20mm in length, 27% from 20-30mm and 7% were >30 mm in length. Higher density clots increased the propensity for clots to travel along the cerebral vessels ( P<0.05). Releasing more clots during each test, increased the probability of at least one clot traveling through an aortic arch branching vessel. Conclusions- Embolus trajectory through the branching vessels of the aortic arch is not exclusively dependent on embolus size. EAs tend to travel proportionally with outlet flow rates, with a greater chance of a stroke caused by multiple breakaway emboli.
引用
- Malone F, McCarthy E, Delassus P, et al. Investigation of the Hemodynamics Influencing Emboli Trajectories Through a Patient-Specific Aortic Arch Model. Stroke. 2019. PMID: 31136292. doi:10.1161/STROKEAHA.118.023581
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。