球囊导引导管在血管内治疗中无论机械再通方式均有益
该回顾性多中心研究纳入955例急性卒中患者,比较使用球囊导引导管(BGC)与未使用者的再通和临床结局。无论首选支架取栓还是抽吸取栓,BGC使用均与更高的成功再通率和良好功能结局独立相关。
要点
- BGC组成功再通率86.8%,显著高于非BGC组的74.7%。
- BGC使用是成功再通的独立预测因素(OR 2.18,95%CI 1.54-3.10)。
- BGC使用也是良好功能结局的独立预测因素(OR 1.40,95%CI 1.02-1.92)。
核心结论
- 无论首选机械取栓方式为支架取栓还是抽吸取栓,使用BGC均与更高的再通成功率和良好功能结局相关。
研究设计与样本
- 回顾性队列研究,纳入全国17个卒中中心前瞻性登记数据库中连续接受支架取栓或抽吸取栓的急性卒中患者955例。
主要发现
- BGC组成功再通率86.8%,非BGC组74.7%(P<0.001)。
- BGC组首过再通率37.0%,非BGC组14.1%(P<0.001)。
- BGC组器械通过次数2.5±1.9次,非BGC组3.3±2.1次(P<0.001)。
- BGC组手术时间54.3±27.4分钟,非BGC组67.6±38.2分钟(P<0.001)。
关键数值与推荐
- BGC使用是成功再通的独立因素(OR 2.18,95%CI 1.54-3.10,P<0.001),不受首选血管内治疗方式影响。
- BGC使用是良好功能结局的独立因素(OR 1.40,95%CI 1.02-1.92,P=0.038),不受首选血管内治疗方式影响。
临床怎么用
- 在急性卒中血管内治疗中,无论采用支架取栓还是抽吸取栓,均可考虑使用BGC以改善再通和功能结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background and Purpose- Based on its mechanism, the use of balloon guide catheters (BGCs) may be beneficial during endovascular treatment, regardless of the type of mechanical recanalization modality used-stent retriever thrombectomy or thrombaspiration. We evaluated whether the use of BGCs can be beneficial regardless of the first-line mechanical endovascular modality used. Methods- We retrospectively reviewed consecutive acute stroke patients who underwent stent retriever thrombectomy or thrombaspiration from the prospectively maintained registries of 17 stroke centers nationwide. Patients were assigned to the BGC or non-BGC group based on the use of BGCs during procedures. Endovascular and clinical outcomes were compared between the BGC and non-BGC groups. To adjust the influence of the type of first-line endovascular modality on successful recanalization and favorable outcome, multivariable analyses were also performed. Results- This study included a total of 955 patients. Stent retriever thrombectomy was used as the first-line modality in 526 patients (55.1%) and thrombaspiration in 429 (44.9%). BGC was used in 516 patients (54.0%; 61.2% of stent retriever thrombectomy patients; 45.2% of thrombaspiration patients). The successful recanalization rate was significantly higher in the BGC group compared with the non-BGC group (86.8% versus 74.7%, respectively; P<0.001). Furthermore, the first-pass recanalization rate was more frequent (37.0% versus 14.1%; P<0.001), and the number of device passes was fewer in the BGC group (2.5±1.9 versus 3.3±2.1; P<0.001). The procedural time was also shorter in the BGC group (54.3±27.4 versus 67.6±38.2; P<0.001). The use of BGC was an independent factor for successful recanalization (odds ratio, 2.18; 95% CI, 1.54-3.10; P<0.001) irrespective of the type of first-line endovascular modality used. The use of BGC was also an independent factor for a favorable outcome (odds ratio, 1.40; 95% CI, 1.02-1.92; P=0.038) irrespective of the type of first-line endovascular modality used. Conclusions- Regardless of the first-line mechanical endovascular modality used, the use of BGC in endovascular treatment was beneficial in terms of both recanalization success and functional outcome.
引用
- Baek JH, Kim BM, Kang DH, et al. Balloon Guide Catheter Is Beneficial in Endovascular Treatment Regardless of Mechanical Recanalization Modality. Stroke. 2019. PMID: 31043149. doi:10.1161/STROKEAHA.118.024723
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。